{"id":48000,"date":"2024-10-17T07:51:08","date_gmt":"2024-10-17T07:51:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ny-fuelgascode-07-2007\/"},"modified":"2024-10-24T16:19:07","modified_gmt":"2024-10-24T16:19:07","slug":"ny-fuelgascode-07-2007","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ny\/ny-fuelgascode-07-2007\/","title":{"rendered":"NY FuelGasCode 07 2007"},"content":{"rendered":"

Based on the 2003 International Fuel Gas Code<\/i>\u00ae. The Fuel Gas Code addresses the design and installation of fuel gas systems and gas-fired appliances through requirements that emphasize performance. This publication is designed to meet these needs by addressing code provisions that safeguard public health and safety in communities both large and small. It incorporates the text of a fuel gas “standard” into a comprehensive, integrated code.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nFUEL GAS CODE OF NEW YORK STATE 2007 <\/td>\n<\/tr>\n
2<\/td>\nCOPYRIGHT \u00a9 2007 <\/td>\n<\/tr>\n
3<\/td>\nACKNOWLEDGMENTS <\/td>\n<\/tr>\n
5<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
7<\/td>\nCHAPTER 1 ADMINISTRATION
SECTION 101 TITLE, SCOPE AND PURPOSE <\/td>\n<\/tr>\n
8<\/td>\nSECTION 102 APPLICABILITY
SECTION 103 MATERIALS, EQUIPMENT AND METHODS OF CONSTRUCTION
SECTION 104 SERVICE UTILITIES
SECTION 105 ADMINISTRATION AND ENFORCEMENT <\/td>\n<\/tr>\n
9<\/td>\nCHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n
19<\/td>\nCHAPTER 3 GENERAL REGULATIONS
SECTION 301 GENERAL <\/td>\n<\/tr>\n
20<\/td>\nSECTION 302 STRUCTURAL SAFETY <\/td>\n<\/tr>\n
22<\/td>\nSECTION 303 APPLIANCE LOCATION
SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR <\/td>\n<\/tr>\n
23<\/td>\n(EQUATION 3-1)
(EQUATION 3-2)
FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3) <\/td>\n<\/tr>\n
24<\/td>\nFIGURE 304.6.1(1) ALL AIR FROM OUTDOORS\u2014INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section 304.6.2) <\/td>\n<\/tr>\n
25<\/td>\nSECTION 305 INSTALLATION <\/td>\n<\/tr>\n
26<\/td>\nSECTION 306 ACCESS AND SERVICE SPACE <\/td>\n<\/tr>\n
27<\/td>\nSECTION 307 CONDENSATE DISPOSAL <\/td>\n<\/tr>\n
28<\/td>\nSECTION 308 (IFGS) CLEARANCE REDUCTION
TABLE 308.2a-k REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION <\/td>\n<\/tr>\n
29<\/td>\nFIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM GAS EQUIPMENT OR VENT CONNECTIONS
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM <\/td>\n<\/tr>\n
30<\/td>\nSECTION 309 ELECTRICAL
SECTION 310 (IFGS)ELECTRICAL BONDING <\/td>\n<\/tr>\n
31<\/td>\nCHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 GENERAL
SECTION 402 (IFGS) PIPE SIZING
TABLE 402.2 APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES <\/td>\n<\/tr>\n
32<\/td>\n(EQUATION 4-1)
(Equation 4-2)
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS <\/td>\n<\/tr>\n
33<\/td>\nTABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
34<\/td>\nTABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
35<\/td>\nTABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
36<\/td>\nTABLE 402.4(7) SEMI-RIGID COPPER TUBING <\/td>\n<\/tr>\n
37<\/td>\nTABLE 402.4(8) SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
38<\/td>\nTABLE 402.4(9) SEMIRIGID COPPER TUBING Use this Table to Size Tubing from House Line Regulator to the Appliance. <\/td>\n<\/tr>\n
39<\/td>\nTABLE 402.4(10) SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
40<\/td>\nTABLE 402.4(11) SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
41<\/td>\nTABLE 402.4(12) SEMIRIGID COPPER TUBING Pipe Sizing Between Point of Delivery and the House Line Regulator. Total Load Supplied by a Single House Line Regulator Not Exceeding 150 Cubic Feet per Hour.2 <\/td>\n<\/tr>\n
42<\/td>\nTABLE 402.4(13) SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
43<\/td>\nTABLE 402.4(14) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
44<\/td>\nTABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
45<\/td>\nTABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
46<\/td>\nTABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
47<\/td>\nTABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
48<\/td>\nTABLE 402.4(19) POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
49<\/td>\nTABLE 402.4(20) POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
50<\/td>\nTABLE 402.4(21) POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
51<\/td>\nTABLE 402.4(22) SCHEDULE 40 METALLIC PIPE Pipe Sizing Between First Stage (High-pressure Regulator) and Second Stage (Low-pressure Regulator) <\/td>\n<\/tr>\n
52<\/td>\nTABLE 402.4(23)SCHEDULE 40 METALLIC PIPE <\/td>\n<\/tr>\n
53<\/td>\nTABLE 402.4(24) SCHEDULE 40 METALLIC PIPE Pipe Sizing Between Single or Second Stage (Low-pressure Regulator) and Appliance <\/td>\n<\/tr>\n
54<\/td>\nTABLE 402.4(25) SEMI-RIGID COPPER TUBING Sizing Between First Stage (High-pressure Regulator) and Second Stage (Low-pressure Regulator) <\/td>\n<\/tr>\n
55<\/td>\nTABLE 402.4(26) SEMI-RIGID COPPER TUBING Sizing Between Single or Second Stage (Low-pressure Regulator) and Appliance <\/td>\n<\/tr>\n
56<\/td>\nTABLE 402.4(27) SEMIRIGID COPPER TUBING <\/td>\n<\/tr>\n
57<\/td>\nTABLE 402.4(28) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
58<\/td>\nTABLE 402.4(29) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
59<\/td>\nTABLE 402.4(30) CORRUGATED STAINLESS STEEL TUBING (CSST) <\/td>\n<\/tr>\n
60<\/td>\nTABLE 402.4(31) POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
61<\/td>\nTABLE 402.4(32) POLYETHYLENE PLASTIC PIPE <\/td>\n<\/tr>\n
62<\/td>\nTABLE 402.4(33) POLYETHYLENE PLASTIC TUBING <\/td>\n<\/tr>\n
63<\/td>\nSECTION 403 (IFGS) PIPING MATERIALS <\/td>\n<\/tr>\n
64<\/td>\nTABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE <\/td>\n<\/tr>\n
65<\/td>\nSECTION 404 PIPING SYSTEM INSTALLATION <\/td>\n<\/tr>\n
66<\/td>\nSECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING <\/td>\n<\/tr>\n
68<\/td>\nTABLE 406.7.1 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS FOR SERVICING OR MODIFICATION
TABLE 406.7.2 LENGTH OF PIPING REQUIRING PURGING WITH INERT GAS BEFORE PLACING IN OPERATION
SECTION 407 PIPING SUPPORT
SECTION 408 DRIPS AND SLOPED PIPING
SECTION 409 SHUTOFF VALVES <\/td>\n<\/tr>\n
69<\/td>\nSECTION 410 FLOW CONTROLS
SECTION 411 APPLIANCE CONNECTIONS <\/td>\n<\/tr>\n
70<\/td>\nSECTION 412 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n
71<\/td>\nSECTION 413 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES <\/td>\n<\/tr>\n
72<\/td>\nTABLE 413.8.2.3 SEPARATION DISTANCE FORATMOSPHERIC VENTING OF CNG
SECTION 414 SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 OVERPRESSURE PROTECTION DEVICES <\/td>\n<\/tr>\n
73<\/td>\nCHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 GENERAL <\/td>\n<\/tr>\n
74<\/td>\nSECTION 502 VENTS
SECTION 503 (IFGS) VENTING OF EQUIPMENT <\/td>\n<\/tr>\n
76<\/td>\nTABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED <\/td>\n<\/tr>\n
77<\/td>\nFIGURE 503.5.4 TYPICAL TERMINATION LOCATIONS FOR CHIMNEYS AND SINGLE-WALL METAL PIPES SERVING RESIDENTIAL-TYPE AND LOW-HEAT EQUIPMENT <\/td>\n<\/tr>\n
78<\/td>\nFIGURE 503.6.6 GAS VENT TERMINATION LOCATIONS FOR LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL <\/td>\n<\/tr>\n
79<\/td>\nFIGURE 503.6.10.1 PLAN VIEW OF PRACTICAL SEPARATION METHOD FOR MULTISTORY GAS VENTING <\/td>\n<\/tr>\n
80<\/td>\nTABLE 503.7.7a CLEARANCES FOR CONNECTORS <\/td>\n<\/tr>\n
81<\/td>\nFIGURE 503.8 EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT SYSTEM <\/td>\n<\/tr>\n
82<\/td>\nTABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT EQUIPMENT AND COMMERCIAL AND INDUSTRIAL INCINERATORS VENT CONNECTOR SIZE <\/td>\n<\/tr>\n
85<\/td>\nSECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS <\/td>\n<\/tr>\n
86<\/td>\nTABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
87<\/td>\nTABLE 504.2(1)\u2014continued TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
88<\/td>\nTABLE 504.2(1)\u2014continued TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
89<\/td>\nTABLE 504.2(1)\u2014continued TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
90<\/td>\nTABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
91<\/td>\nTABLE 504.2(2)\u2014continued TYPE B DOUBLE-WALL GAS VENT <\/td>\n<\/tr>\n
92<\/td>\nTABLE 504.2(3) MASONRY CHIMNEY <\/td>\n<\/tr>\n
93<\/td>\nTABLE 504.2(3)\u2014continued MASONRY CHIMNEY <\/td>\n<\/tr>\n
94<\/td>\nTABLE 504.2(4) MASONRY CHIMNEY <\/td>\n<\/tr>\n
95<\/td>\nTABLE 504.2(4)\u2014continued MASONRY CHIMNEY <\/td>\n<\/tr>\n
96<\/td>\nTABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT <\/td>\n<\/tr>\n
98<\/td>\nTABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH <\/td>\n<\/tr>\n
100<\/td>\nSECTION 505 DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION\/EXHAUST HOOD VENTING
SECTION 506 FACTORY-BUILT CHIMNEYS <\/td>\n<\/tr>\n
101<\/td>\nTABLE 504.3(1) TYPE B DOUBLE-WALL VENT <\/td>\n<\/tr>\n
102<\/td>\nTABLE 504.3(1)\u2014continued TYPE B DOUBLE-WALL VENT <\/td>\n<\/tr>\n
103<\/td>\nTABLE 504.3(2) TYPE B DOUBLE-WALL VENT <\/td>\n<\/tr>\n
105<\/td>\nTABLE 504.3(4) MASONRY CHIMNEY <\/td>\n<\/tr>\n
106<\/td>\nTABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT <\/td>\n<\/tr>\n
107<\/td>\nTABLE 504.3(6) EXTERIOR MASONRY CHIMNEY <\/td>\n<\/tr>\n
108<\/td>\nTABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b)\u2014continued EXTERIOR MASONRY CHIMNEY <\/td>\n<\/tr>\n
109<\/td>\nTABLE 504.3(8a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(8b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(8b)\u2014continued EXTERIOR MASONRY CHIMNEY <\/td>\n<\/tr>\n
111<\/td>\nCHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 GENERAL
SECTION 602 DECORATIVE APPLIANCESFOR INSTALLATION IN FIREPLACES
SECTION 603 LOG LIGHTERS
SECTION 604 VENTED GAS FIREPLACES(DECORATIVE APPLIANCES)
SECTION 605 VENTED GAS FIREPLACE HEATERS
SECTION 606 INCINERATORS AND CREMATORIES
SECTION 607 COMMERCIAL-INDUSTRIAL INCINERATORS <\/td>\n<\/tr>\n
112<\/td>\nSECTION 608 VENTED WALL FURNACES
SECTION 609 FLOOR FURNACES
SECTION 610 DUCT FURNACES <\/td>\n<\/tr>\n
113<\/td>\nSECTION 611 NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 612 RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS <\/td>\n<\/tr>\n
114<\/td>\nSECTION 613 CLOTHES DRYERS
SECTION 614 CLOTHES DRYER EXHAUST
SECTION 615 SAUNA HEATERS <\/td>\n<\/tr>\n
115<\/td>\nSECTION 616 ENGINE AND GAS TURBINE POWEREDEQUIPMENT
SECTION 617 POOL AND SPA HEATERS
SECTION 618 FORCED-AIR WARM-AIR FURNACES <\/td>\n<\/tr>\n
116<\/td>\nSECTION 619 CONVERSION BURNERS
SECTION 620 UNIT HEATERS
SECTION 621 UNVENTED ROOM HEATERS
SECTION 622 VENTED ROOM HEATERS
SECTION 623 COOKING APPLIANCES <\/td>\n<\/tr>\n
117<\/td>\nSECTION 624 WATER HEATERS
SECTION 625 REFRIGERATORS
SECTION 626 GAS-FIRED TOILETS
SECTION 627 AIR-CONDITIONING EQUIPMENT <\/td>\n<\/tr>\n
118<\/td>\nSECTION 628 ILLUMINATING APPLIANCES
SECTION 629 SMALL CERAMIC KILNS
SECTION 630 INFRARED RADIANT HEATERS
SECTION 631 BOILERS <\/td>\n<\/tr>\n
119<\/td>\nSECTION 632 EQUIPMENT INSTALLED IN EXISTINGUNLISTED BOILERS
SECTION 633 FUEL CELL POWER PLANTS
TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA <\/td>\n<\/tr>\n
121<\/td>\nCHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 GENERAL
SECTION 702 GENERAL DEFINITIONS
SECTION 703 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n
122<\/td>\nSECTION 704 PIPING, USE AND HANDLING <\/td>\n<\/tr>\n
123<\/td>\nSECTION 705 TESTING OF HYDROGEN PIPING SYSTEMS <\/td>\n<\/tr>\n
124<\/td>\nSECTION 706 LOCATION OF GASEOUS HYDROGEN SYSTEMS <\/td>\n<\/tr>\n
125<\/td>\nSECTION 707 OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS <\/td>\n<\/tr>\n
127<\/td>\nCHAPTER 8 REFERENCED STANDARDS
ANSI <\/td>\n<\/tr>\n
128<\/td>\nASME
ASTM
AWWA
CGA <\/td>\n<\/tr>\n
129<\/td>\nCSA
DOTn
MSS
NFPA <\/td>\n<\/tr>\n
130<\/td>\nUL <\/td>\n<\/tr>\n
131<\/td>\nAPPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1)THROUGH 402.4(21) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60 <\/td>\n<\/tr>\n
132<\/td>\nTABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES <\/td>\n<\/tr>\n
133<\/td>\nTABLE A.2.2 \u2014 continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES <\/td>\n<\/tr>\n
135<\/td>\nHIGH PRESSURE SIZING EQUATION <\/td>\n<\/tr>\n
136<\/td>\nLOW PRESSURE SIZING EQUATION
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES <\/td>\n<\/tr>\n
137<\/td>\nFIGURE A.6 (a) CAPACITY OF NATURAL GAS PIPING, LOW PRESSURE (0.60 WC) <\/td>\n<\/tr>\n
138<\/td>\nFIGURE A.6 (b) CAPACITY OF NATURAL GAS PIPING, HIGH PRESSURE (1.5 psi and above) <\/td>\n<\/tr>\n
139<\/td>\nFIGURE A.7.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.7.2 PIPING PLAN SHOWING A CSST SYSTEM <\/td>\n<\/tr>\n
140<\/td>\nFIGURE A.7.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.7.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM <\/td>\n<\/tr>\n
141<\/td>\nAPPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR <\/td>\n<\/tr>\n
142<\/td>\nFIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR <\/td>\n<\/tr>\n
143<\/td>\nFIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES <\/td>\n<\/tr>\n
144<\/td>\nFIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS <\/td>\n<\/tr>\n
145<\/td>\nFIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE <\/td>\n<\/tr>\n
146<\/td>\nFIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFTHOOD-EQUIPPED APPLIANCES <\/td>\n<\/tr>\n
147<\/td>\nFIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT <\/td>\n<\/tr>\n
148<\/td>\nTABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa <\/td>\n<\/tr>\n
149<\/td>\nFIGURE B-19 <\/td>\n<\/tr>\n
151<\/td>\nAPPENDIX C (IFGS) Reserved <\/td>\n<\/tr>\n
153<\/td>\nAPPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION <\/td>\n<\/tr>\n
155<\/td>\nAPPENDIX E (IFGS) STRUCTURAL SAFETY
BORING OF BEARING STUDS <\/td>\n<\/tr>\n
156<\/td>\nBORED HOLES IN JOISTS
NOTCHES AT ENDS OF JOISTS <\/td>\n<\/tr>\n
157<\/td>\nINDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Fuel Gas Code of New York State<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
NY<\/b><\/a><\/td>\n2007<\/td>\n160<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":48001,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2744],"product_tag":[],"class_list":{"0":"post-48000","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ny","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/48000","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/48001"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=48000"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=48000"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=48000"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}