{"id":446256,"date":"2024-10-20T08:45:55","date_gmt":"2024-10-20T08:45:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-23-30454436-dc-2023\/"},"modified":"2024-10-26T16:19:53","modified_gmt":"2024-10-26T16:19:53","slug":"bsi-23-30454436-dc-2023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-23-30454436-dc-2023\/","title":{"rendered":"BSI 23\/30454436 DC 2023"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
8<\/td>\nFOREWORD <\/td>\n<\/tr>\n
10<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
11<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
14<\/td>\n4 Requirements
4.1 General
4.1.1 Design
4.1.2 Battery dimensions
4.1.3 Terminals
4.1.3.1 General <\/td>\n<\/tr>\n
15<\/td>\n4.1.3.2 Contact pressure resistance
4.1.3.3 Cap and base
4.1.3.4 Cap and case
4.1.3.5 Screw terminals
4.1.3.6 Flat contacts
4.1.3.7 Flat or spiral springs
4.1.3.8 Plug-in-sockets
4.1.3.9 Snap fasteners
4.1.3.9.1 General
4.1.3.9.2 Snap fastener <\/td>\n<\/tr>\n
16<\/td>\n4.1.3.10 Wire
4.1.3.11 Other spring contacts or clips
4.1.4 Classification (electrochemical system) <\/td>\n<\/tr>\n
17<\/td>\n4.1.5 Designation
4.1.6 Marking
4.1.6.1 General
4.1.6.2 Marking of smaller batteries <\/td>\n<\/tr>\n
18<\/td>\n4.1.6.3 Marking of batteries regarding method of disposal
4.1.7 Interchangeability: battery voltage <\/td>\n<\/tr>\n
19<\/td>\n4.2 Performance
4.2.1 Discharge performance
4.2.2 Dimensional stability
4.2.3 Leakage
4.2.4 Open-circuit voltage limits
4.2.5 Service output
4.2.6 Safety <\/td>\n<\/tr>\n
20<\/td>\n4.2.7 Validity of testing
5 Performance \u2013 Testing
5.1 Capacity testing versus application and service output testing
5.2 Discharge testing
5.2.1 General <\/td>\n<\/tr>\n
21<\/td>\n5.2.2 Application tests
5.2.2.1 General
5.2.2.2 Application tests with multiple loads
5.2.3 Service output tests <\/td>\n<\/tr>\n
22<\/td>\n5.3 Conformance check to a specified minimum average duration
5.4 Guidance for considering proposed value of minimum average duration
5.5 OCV testing
5.6 Insulation resistance
5.7 Battery dimensions
5.8 Leakage and deformation <\/td>\n<\/tr>\n
23<\/td>\n6 Performance \u2013 Test conditions
6.1 Storage and discharge conditions
6.2 Commencement of discharge tests after storage
6.3 Discharge test conditions
6.3.1 General
6.3.2 Compliance <\/td>\n<\/tr>\n
24<\/td>\n6.4 Load resistance
6.5 Time periods
6.6 Test condition tolerances <\/td>\n<\/tr>\n
25<\/td>\n6.7 Activation of \u2018P\u2019-system batteries
6.8 Measuring equipment
6.8.1 Voltage measurement
6.8.2 Mechanical measurement
7 Sampling and quality assurance
8 Battery packaging <\/td>\n<\/tr>\n
26<\/td>\nAnnex A (normative) Criteria for the standardization of batteries <\/td>\n<\/tr>\n
27<\/td>\nAnnex B (informative) Recommendations for equipment design
B.1 Technical liaison
B.2 Battery compartment
B.2.1 General <\/td>\n<\/tr>\n
28<\/td>\nB.2.2 Limiting access by children
B.3 Voltage cut-off <\/td>\n<\/tr>\n
29<\/td>\nAnnex C (normative) Designation system (nomenclature)
C.1 General
C.2 Designation system in use up to October 1990
C.2.1 General
C.2.2 Cells <\/td>\n<\/tr>\n
31<\/td>\nC.2.3 Electrochemical system
C.2.4 Batteries <\/td>\n<\/tr>\n
32<\/td>\nC.2.5 Modifiers
C.2.6 Examples
C.3 Designation system in use since October 1990
C.3.1 General
C.3.2 Round batteries
C.3.2.1 Round batteries with diameter and height less than 100 mm
C.3.2.1.1 General <\/td>\n<\/tr>\n
33<\/td>\nC.3.2.1.2 Method for assigning the diameter code <\/td>\n<\/tr>\n
34<\/td>\nC.3.2.1.3 Method for assigning the height code <\/td>\n<\/tr>\n
35<\/td>\nC.3.2.2 Round batteries with diameter and\/or height over or equal to 100 mm
C.3.2.2.1 General <\/td>\n<\/tr>\n
36<\/td>\nC.3.2.2.2 Method for assigning the diameter code
C.3.2.2.3 Method for assigning the height code
C.3.3 Non-round batteries
C.3.3.1 General <\/td>\n<\/tr>\n
37<\/td>\nC.3.3.2 Non-round batteries with dimensions < 100 mm
C.3.3.3 Non-round batteries with dimensions \u2265 100 mm <\/td>\n<\/tr>\n
39<\/td>\nC.3.4 Ambiguity <\/td>\n<\/tr>\n
41<\/td>\nAnnex D (informative) Standard discharge voltage Us \u2013 Definition and method of determination
D.1 Definition
D.2 Determination
D.2.1 General considerations: the C\/R-plot <\/td>\n<\/tr>\n
42<\/td>\nD.2.2 Determination of the standard discharge resistor Rs <\/td>\n<\/tr>\n
43<\/td>\nD.2.3 Determination of the standard discharge capacity Cs and standard discharge time ts <\/td>\n<\/tr>\n
44<\/td>\nD.3 Experimental conditions to be observed and test results <\/td>\n<\/tr>\n
45<\/td>\nAnnex E (informative) Preparation of standard methods of measuring performance (SMMP) of consumer goods
E.1 General
E.2 Performance characteristics
E.3 Criteria for the development of test methods <\/td>\n<\/tr>\n
46<\/td>\nAnnex F (informative) Guidance for proposing value of minimum average duration
F.1 General
F.2 Sampling
F.3 Calculation method <\/td>\n<\/tr>\n
47<\/td>\nAnnex G (normative) Code of practice for packaging, shipment, storage, use and disposal of primary batteries
G.1 General
G.2 Packaging
G.3 Transport and handling
G.4 Storage and stock rotation <\/td>\n<\/tr>\n
48<\/td>\nG.5 Displays at sales points
G.6 Selection, use and disposal
G.6.1 Purchase
G.6.2 Installation
G.6.3 Use <\/td>\n<\/tr>\n
49<\/td>\nG.6.4 Replacement
G.6.5 Disposal <\/td>\n<\/tr>\n
50<\/td>\nAnnex H (informative) Common designation <\/td>\n<\/tr>\n
51<\/td>\nAnnex I (informative ) Measurement methods for the determination of the performance and durability of batteries of general use
I.1 Scope
I.2 Normative references
I.3 Terms and definitions
I.3.1 non-rechargeable battery
I.3.2 portable battery of general use <\/td>\n<\/tr>\n
52<\/td>\nI.4 Interoperability
I.5 Portable batteries of general use
I.6 Performance and durability tests
I.6.1 Minimum average duration
I.6.1.1 Primary cells and batteries of general use <\/td>\n<\/tr>\n
54<\/td>\nI.6.1.2 Other primary cells and batteries
I.6.2 Delayed discharge performance
I.6.3 Resistance to leakage <\/td>\n<\/tr>\n
55<\/td>\nAnnex J (informative) Compliance checklist <\/td>\n<\/tr>\n
56<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

BS EN 60086-1. Primary batteries – Part 1. General<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2023<\/td>\n56<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":446267,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[538,2641],"product_tag":[],"class_list":{"0":"post-446256","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-220-10","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/446256","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/446267"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=446256"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=446256"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=446256"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}