{"id":311944,"date":"2024-10-19T21:26:48","date_gmt":"2024-10-19T21:26:48","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-13100-22019\/"},"modified":"2024-10-25T19:22:41","modified_gmt":"2024-10-25T19:22:41","slug":"bs-en-13100-22019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-13100-22019\/","title":{"rendered":"BS EN 13100-2:2019"},"content":{"rendered":"
This document specifies fundamental radiographic techniques with film, which enable repeatable results to be obtained economically. This document applies to the X-ray radiographic examination of heated tool, electrofusion, extrusion and hot gas joints in plastics materials. It applies to joints in solid wall pipes and plates with a range of thicknesses from 5 mm to 100 mm. It only applies to pipes containing air or other gases at the time of X-ray testing. This document does not specify acceptance levels of the indications.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 4 Symbols and abbreviations <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 5 General 5.1 Security measures 5.2 Surface preparation and stage of manufacture 5.3 Location of the weld in the radiograph 5.4 Identification of radiographs <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 5.5 Marking 5.6 Overlap of films 5.7 Types and position of image quality indicators (IQI) 5.8 Evaluation of image quality <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 5.9 Minimum image quality values 5.10 Personnel qualification 6 Recommended techniques for making radiographs 6.1 Test arrangements <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 6.2 Choice of tube voltage 6.3 Film systems and screens 6.4 Alignment of beam <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 6.5 Source-to-object distance 6.6 Maximum area for a single exposure 6.7 Density of radiograph 6.8 Processing <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.9 Film viewing conditions 7 Examination report <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex\u00a0A (normative)Minimum image quality values A.1 Single-wall technique; IQI on source side <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | A.2 Double-wall technique; double image; IQI on source side A.3 Double-wall thickness; single or double image; IQI on film side <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Annex\u00a0B (informative)Recommended number of exposures when using the perpendicular, double- wall, single-image and single-wall off-centre techniques for a circumferential butt weld <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Non-destructive testing of welded joints in thermoplastics semi- finished products – X-ray radiographic testing<\/b><\/p>\n |