{"id":290826,"date":"2024-10-19T19:44:25","date_gmt":"2024-10-19T19:44:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-165922012\/"},"modified":"2024-10-25T16:45:09","modified_gmt":"2024-10-25T16:45:09","slug":"bs-iso-165922012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-165922012\/","title":{"rendered":"BS ISO 16592:2012"},"content":{"rendered":"
This International Standard gives guidance on a method for the determination of the carbon content in steels containing other alloying elements (less than 1 % to 2 % by mass) using the calibration curve method. It specifies the sample preparation, X-ray detection, establishment of the calibration curve and the procedure for the determination of the uncertainty of the measured carbon content. It is applicable to steels containing a mass fraction of carbon of less than 1,0 %. The method is not applicable to steels with higher carbon contents, which could significantly affect the accuracy of the analysis results.<\/p>\n
This International Standard applies to analyses performed using normal beam incidence and wavelength-dispersive X-ray spectrometry; it is not designed to be used for energy-dispersive X-ray spectrometry.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | CVP_Secretariat_Loca <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1\tScope 2\tProcedure 2.1\tGeneral 2.2\tReference materials 2.3\tSpecimen preparation <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 2.4\tMeasurement of carbon K\u03b1 X\u2011ray intensity <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 2.5\tBackground subtraction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 2.6\tEstablishment of the calibration curve <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3\tEvaluation of uncertainty 4\tTest report <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Annex\u00a0A \n(informative)<\/p>\n Method of estimating the uncertainty of the calculated value using a calibration curve <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Annex\u00a0B \n(informative)<\/p>\n A practical example of the determination of the mass fraction of carbon and the evaluation of uncertainty in a steel <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Microbeam analysis. Electron probe microanalysis. Guidelines for determining the carbon content of steels using a calibration curve method<\/b><\/p>\n |