{"id":277618,"date":"2024-10-19T18:41:44","date_gmt":"2024-10-19T18:41:44","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-141172012\/"},"modified":"2024-10-25T15:12:31","modified_gmt":"2024-10-25T15:12:31","slug":"bs-iso-141172012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-141172012\/","title":{"rendered":"BS ISO 14117:2012"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | CVP_Secretariat_Loca <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1\tScope 2\tNormative references 3\tTerms and definitions, symbols and abbreviations <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4\tTest requirements for the frequency band 0 Hz\u00a0\u2264\u00a0\u0192\u00a0\u2264\u00a03\u00a0000\u00a0MHz 4.1\tGeneral <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.2\tInduced lead current <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | SameLvl <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.3\tProtection from persisting malfunction attributable to ambient electromagnetic fields <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 4.4\tTemporary response to continuous wave sources <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 4.5\tProtection from sensing EMI as cardiac signals <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | n <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 4.6\tProtection from static magnetic fields of flux density up to 1 mT <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 4.7\tProtection from static magnetic fields of flux density up to 50 mT <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 4.8\tProtection from AC magnetic field exposure in the range of 1 kHz to 140 kHz <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 4.9\tTest requirements for the frequency range of 450 MHz\u00a0\u2264\u00a0\u0192\u00a0\u2264\u00a03\u00a0000\u00a0MHz <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | PrevLvl <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 5\tTesting above frequency of 3\u00a0000 MHz 6\tProtection of devices from EM fields encountered in a therapeutic environment 6.1\tProtection of the device from damage caused by high-frequency surgical exposure <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 6.2\tProtection of the device from damage caused by external defibrillators <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 7\tAdditional accompanying documentation 7.1\tDisclosure of permanently programmable sensitivity settings 7.2\tDescriptions of reversion modes 7.3\tKnown potential hazardous behaviour <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Annex\u00a0A \n(informative)<\/p>\n Rationale <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | Annex\u00a0B \n(informative)<\/p>\n Rationale for test frequency ranges <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Annex\u00a0C \n(informative)<\/p>\n Code for describing modes of implantable generators <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Annex\u00a0D \n(normative)<\/p>\n Interface circuits <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex\u00a0E \n(informative)<\/p>\n Selection of capacitor Cx <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | Annex\u00a0F \n(normative)<\/p>\n Calibration of the injection network (Figure\u00a0D.5) <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Annex\u00a0G \n(normative)<\/p>\n Torso simulator <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | Annex\u00a0H \n(normative)<\/p>\n Dipole antennas Dipole antennas <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | Annex\u00a0I \n(normative)<\/p>\n Pacemaker\/ICD programming settings Pacemaker\/ICD programming settings <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | Annex\u00a0J \n(normative)<\/p>\n Simulated cardiac signal Simulated cardiac signal <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | Annex\u00a0K \n(normative)<\/p>\n Calculation of net power into dipole antenna Calculation of net power into dipole antenna <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | Annex\u00a0L \n(informative)<\/p>\n Loop area calculations Loop area calculations <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | Annex\u00a0M \n(informative)<\/p>\n Correlation between levels of test voltages used in this International Standard and strengths of radiated fields Correlation between levels of test voltages used in this International Standard and strengths of radiated fields <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | Bibliography Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Active implantable medical devices. Electromagnetic compatibility. EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices<\/b><\/p>\n |