{"id":277618,"date":"2024-10-19T18:41:44","date_gmt":"2024-10-19T18:41:44","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-141172012\/"},"modified":"2024-10-25T15:12:31","modified_gmt":"2024-10-25T15:12:31","slug":"bs-iso-141172012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-141172012\/","title":{"rendered":"BS ISO 14117:2012"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
3<\/td>\nCVP_Secretariat_Loca <\/td>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nIntroduction <\/td>\n<\/tr>\n
10<\/td>\n1\tScope
2\tNormative references
3\tTerms and definitions, symbols and abbreviations <\/td>\n<\/tr>\n
12<\/td>\n4\tTest requirements for the frequency band 0 Hz\u00a0\u2264\u00a0\u0192\u00a0\u2264\u00a03\u00a0000\u00a0MHz
4.1\tGeneral <\/td>\n<\/tr>\n
13<\/td>\n4.2\tInduced lead current <\/td>\n<\/tr>\n
14<\/td>\nSameLvl <\/td>\n<\/tr>\n
20<\/td>\n4.3\tProtection from persisting malfunction attributable to ambient electromagnetic fields <\/td>\n<\/tr>\n
30<\/td>\n4.4\tTemporary response to continuous wave sources <\/td>\n<\/tr>\n
33<\/td>\n4.5\tProtection from sensing EMI as cardiac signals <\/td>\n<\/tr>\n
35<\/td>\nn <\/td>\n<\/tr>\n
43<\/td>\n4.6\tProtection from static magnetic fields of flux density up to 1 mT <\/td>\n<\/tr>\n
44<\/td>\n4.7\tProtection from static magnetic fields of flux density up to 50 mT <\/td>\n<\/tr>\n
45<\/td>\n4.8\tProtection from AC magnetic field exposure in the range of 1 kHz to 140 kHz <\/td>\n<\/tr>\n
46<\/td>\n4.9\tTest requirements for the frequency range of 450 MHz\u00a0\u2264\u00a0\u0192\u00a0\u2264\u00a03\u00a0000\u00a0MHz <\/td>\n<\/tr>\n
49<\/td>\nPrevLvl <\/td>\n<\/tr>\n
50<\/td>\n5\tTesting above frequency of 3\u00a0000 MHz
6\tProtection of devices from EM fields encountered in a therapeutic environment
6.1\tProtection of the device from damage caused by high-frequency surgical exposure <\/td>\n<\/tr>\n
51<\/td>\n6.2\tProtection of the device from damage caused by external defibrillators <\/td>\n<\/tr>\n
55<\/td>\n7\tAdditional accompanying documentation
7.1\tDisclosure of permanently programmable sensitivity settings
7.2\tDescriptions of reversion modes
7.3\tKnown potential hazardous behaviour <\/td>\n<\/tr>\n
56<\/td>\nAnnex\u00a0A
\n(informative)<\/p>\n

Rationale <\/td>\n<\/tr>\n

67<\/td>\nAnnex\u00a0B
\n(informative)<\/p>\n

Rationale for test frequency ranges <\/td>\n<\/tr>\n

72<\/td>\nAnnex\u00a0C
\n(informative)<\/p>\n

Code for describing modes of implantable generators <\/td>\n<\/tr>\n

74<\/td>\nAnnex\u00a0D
\n(normative)<\/p>\n

Interface circuits <\/td>\n<\/tr>\n

79<\/td>\nAnnex\u00a0E
\n(informative)<\/p>\n

Selection of capacitor Cx <\/td>\n<\/tr>\n

80<\/td>\nAnnex\u00a0F
\n(normative)<\/p>\n

Calibration of the injection network (Figure\u00a0D.5) <\/td>\n<\/tr>\n

82<\/td>\nAnnex\u00a0G
\n(normative)<\/p>\n

Torso simulator <\/td>\n<\/tr>\n

85<\/td>\nAnnex\u00a0H
\n(normative)<\/p>\n

Dipole antennas
Annex\u00a0H
\n(normative)<\/p>\n

Dipole antennas <\/td>\n<\/tr>\n

87<\/td>\nAnnex\u00a0I
\n(normative)<\/p>\n

Pacemaker\/ICD programming settings
Annex\u00a0I
\n(normative)<\/p>\n

Pacemaker\/ICD programming settings <\/td>\n<\/tr>\n

89<\/td>\nAnnex\u00a0J
\n(normative)<\/p>\n

Simulated cardiac signal
Annex\u00a0J
\n(normative)<\/p>\n

Simulated cardiac signal <\/td>\n<\/tr>\n

90<\/td>\nAnnex\u00a0K
\n(normative)<\/p>\n

Calculation of net power into dipole antenna
Annex\u00a0K
\n(normative)<\/p>\n

Calculation of net power into dipole antenna <\/td>\n<\/tr>\n

94<\/td>\nAnnex\u00a0L
\n(informative)<\/p>\n

Loop area calculations
Annex\u00a0L
\n(informative)<\/p>\n

Loop area calculations <\/td>\n<\/tr>\n

99<\/td>\nAnnex\u00a0M
\n(informative)<\/p>\n

Correlation between levels of test voltages used in this International Standard and strengths of radiated fields
Annex\u00a0M
\n(informative)<\/p>\n

Correlation between levels of test voltages used in this International Standard and strengths of radiated fields <\/td>\n<\/tr>\n

105<\/td>\nBibliography
Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Active implantable medical devices. Electromagnetic compatibility. EMC test protocols for implantable cardiac pacemakers, implantable cardioverter defibrillators and cardiac resynchronization devices<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2013<\/td>\n108<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":277622,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[141,2641],"product_tag":[],"class_list":{"0":"post-277618","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-11-040-40","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/277618","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/277622"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=277618"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=277618"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=277618"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}