{"id":255639,"date":"2024-10-19T16:54:01","date_gmt":"2024-10-19T16:54:01","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-cen-tr-171672018\/"},"modified":"2024-10-25T12:22:01","modified_gmt":"2024-10-25T12:22:01","slug":"bsi-pd-cen-tr-171672018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-cen-tr-171672018\/","title":{"rendered":"BSI PD CEN\/TR 17167:2018"},"content":{"rendered":"
This Technical Report contains additional information to the requirements determined in EN 13757-2, EN 13757-3 and EN 13757-7, in particular examples for the implementation, Datagram examples secured by security mechanism of part 7 and additional non-normative requirements beyond meter communication itself.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 Symbols and abbreviations <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5 Overview <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Annex A (informative)Examples A.1 General A.2 Example for a RSP-UD A.3 Example baud rate switch <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | A.4 Example application select with subcode A.5 Writing data to a slave <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | A.6 Configuring M-Bus data output A.6.1 General <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | A.6.2 Selection of data records with special data field <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | A.6.3 Selection of data records with object action code A.6.4 Deselection of data records <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | A.7 FCB and selection A.7.1 FCB-implementation slave A.7.2 FCB-implementation master <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | A.8 Use of the fabrication number <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Annex B (informative)Secondary search – Instructions for implementation of wildcard search <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex C (informative)Consumer feedback for smart metering applications C.1 General C.2 Resolution of required values and accuracy of time information C.2.1 General <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | C.2.2 Resolution in case of transmission of extra data points for power\/flow rate C.2.3 Resolution in case of non-transmission of extra data points for power\/flow rate C.2.3.1 General <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | C.2.3.2 Assumptions on time information for wireless connections C.2.4 Transmission on request <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex D (informative)Installation and registration D.1 General <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | D.2 Registration with meter support D.2.1 Introduction D.2.2 RF-Link feedback D.2.3 Registration feedback D.3 Registration without meter support <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex E (informative)M-Bus data container E.1 Explanation E.2 Definition <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | E.3 Example <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Annex F (informative)Datagram examples for the M-Bus and the wM-Bus F.1 Colour coding of the datagram examples F.2 Security mode 5 example <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | F.3 Security mode 7 example <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | F.4 Security mode 8 example <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | F.5 Security Mode 9 example F.5.1 General F.5.2 Example input vectors <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | F.5.3 Example Mode 9 on SND-NR datagram <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | F.5.4 Example applying Mode 9 on RSP-UD datagram <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | F.6 Security mode 10 example <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | F.7 Special messages F.7.1 Installation procedure with a special installation message <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | F.7.2 Send a command with an acknowledge <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | F.7.3 Request of the selected data <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | F.7.4 Reset of the link by a SND-NKE <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | F.7.5 Key transfer according SITP <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | F.7.6 Transfer secured application data according SITP <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | Annex G (informative)Descriptors G.1 General G.2 Storage descriptors G.2.1 Storage interval descriptor <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | G.2.2 Storage range descriptor G.3 Subunit descriptor <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | G.4 Tariff descriptor <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | G.5 Examples G.5.1 Example: Storage descriptor <\/td>\n<\/tr>\n | ||||||
88<\/td>\n | G.5.2 Example: Subunit descriptor G.5.3 Example: Tariff descriptor <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Communication system for meters. Accompanying TR to EN 13757-2,-3 and -7, Examples and supplementary information<\/b><\/p>\n |