{"id":250348,"date":"2024-10-19T16:30:52","date_gmt":"2024-10-19T16:30:52","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iec-61892-62019\/"},"modified":"2024-10-25T11:44:14","modified_gmt":"2024-10-25T11:44:14","slug":"bs-iec-61892-62019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iec-61892-62019\/","title":{"rendered":"BS IEC 61892-6:2019"},"content":{"rendered":"
This part of IEC 61892 provides specific requirements for the installation of electrical equipment in mobile and fixed offshore units, including pipeline, pumping or “pigging” stations, compressor stations and single buoy moorings, used in the offshore petroleum industry for drilling, production, accommodation, processing, storage and offloading purposes.<\/p>\n
It applies to all installations, whether permanent, temporary, transportable or hand-held, to AC installations and DC installations without any voltage level limitation. Referenced equipment standards may give voltage level limitations.<\/p>\n
This document specifies requirements such as those concerning<\/p>\n
protection during equipment storage and in the installation period,<\/p>\n<\/li>\n
installation of generators and motors,<\/p>\n<\/li>\n
installation of transformers,<\/p>\n<\/li>\n
installation of switchgear and controlgear assemblies,<\/p>\n<\/li>\n
installation of semiconductor converters and UPS,<\/p>\n<\/li>\n
installation of secondary cells and batteries,<\/p>\n<\/li>\n
installation of luminaires,<\/p>\n<\/li>\n
installation of heating and cooking appliances,<\/p>\n<\/li>\n
installation of trace and surface heating,<\/p>\n<\/li>\n
installation of cables and wiring, both low-voltage and high-voltage cables,<\/p>\n<\/li>\n
requirements in relation to earthing and bonding,<\/p>\n<\/li>\n
lightning protection;,<\/p>\n<\/li>\n
testing of completed installation, and<\/p>\n<\/li>\n
documentation.<\/p>\n<\/li>\n<\/ul>\n
This document does not apply to<\/p>\n
fixed equipment for medical purposes,<\/p>\n<\/li>\n
electrical installations of tankers, and<\/p>\n<\/li>\n
control of ignition sources other than those created by electrical equipment.<\/p>\n<\/li>\n<\/ul>\n
\nNOTE 1 For medical rooms, IEC 60364-7-710 provides specific requirements. Requirements for tankers are given in IEC 60092-502.<\/p>\n
NOTE 2 Guidance on protection of non-electrical equipment can be found in ISO 80079-36, ISO 80079-37 and IMO 2009 MODU Code, 6.7.<\/p>\n<\/blockquote>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 4<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 7<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 9<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 10<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 11<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 15<\/td>\n 4 General requirements
4.1 Labelling
4.2 Protection during equipment storage
4.3 Protection during installation period
5 Generators and motors \u2013 Installation
6 Transformers \u2013 Installation and location <\/td>\n<\/tr>\n\n 16<\/td>\n 7 Switchgear and controlgear assemblies
7.1 Location <\/td>\n<\/tr>\n\n 17<\/td>\n 7.2 Insulating flooring or insulating mats
7.3 Passageways in front of switchgear and controlgear assemblies
7.4 Space at the rear and passageways <\/td>\n<\/tr>\n\n 18<\/td>\n 8 Semiconductor converters
9 Secondary cells and batteries
9.1 General
9.2 Location <\/td>\n<\/tr>\n\n 19<\/td>\n 9.3 Electrical installation in battery compartments
Tables
Table 1 \u2013 Location of batteries versus charging power <\/td>\n<\/tr>\n\n 20<\/td>\n 9.4 Protection against corrosion
9.5 Fixing and supports
9.6 Protection against electric shock <\/td>\n<\/tr>\n\n 21<\/td>\n 9.7 Identification labels or marking
10 Uninterruptible power systems
11 Luminaires
11.1 Degree of protection and safety requirements <\/td>\n<\/tr>\n\n 22<\/td>\n 11.2 Emergency and escape lighting
11.3 Navigation aid and obstruction light system
12 Heating and cooking appliances
12.1 Guarding of combustible materials
12.2 Position of controlgear and switchgear
12.3 Mounting of space-heating appliances
13 Trace and surface heating
13.1 General
13.2 Trace heating cables <\/td>\n<\/tr>\n\n 23<\/td>\n 13.3 Marking
13.4 Protection
13.5 Requirements for installation in hazardous areas
13.6 Mechanical protection
13.7 Junction boxes
14 Cables and wiring
14.1 General
14.2 Installation <\/td>\n<\/tr>\n\n 24<\/td>\n Figures
Figure 1 \u2013 Recommended arrangement for installation of single-core cables \u2013 Flat configuration
Figure 2 \u2013 Recommended arrangement for installation of single-core cables \u2013 Trefoil configuration <\/td>\n<\/tr>\n\n 25<\/td>\n 14.3 Cable runs
14.4 Bending radius <\/td>\n<\/tr>\n\n 26<\/td>\n 14.5 Cable cleating and strapping
Table 2 \u2013 Bending radii for cables rated up to 1,8\/3 kV
Table 3 \u2013 Bending radii for cables rated at 3,6\/6,0(7,2) kVand up to and including 18\/30 kV <\/td>\n<\/tr>\n\n 27<\/td>\n 14.6 Splices and branch circuits
14.7 Cable glands \u2013 Blanking and drain plugs
14.8 Cable termination
14.8.1 General
Table 4 \u2013 Enclosure-gland type <\/td>\n<\/tr>\n\n 29<\/td>\n 14.8.2 Earthing of braid armour and electrostatic screen of instrument and intrinsically safe cables
14.9 Cable transit systems <\/td>\n<\/tr>\n\n 30<\/td>\n 14.10 Cable ladders and trays <\/td>\n<\/tr>\n \n 31<\/td>\n 15 Equipment earthing and bonding
15.1 General
15.2 Earthing of exposed-conductive-parts <\/td>\n<\/tr>\n\n 32<\/td>\n Table 5 \u2013 Sizes of earth continuity conductors and equipment earthing connections <\/td>\n<\/tr>\n \n 33<\/td>\n 15.3 Equipotential bonding
15.4 Bonding connections
15.5 Connections to the unit structure <\/td>\n<\/tr>\n\n 34<\/td>\n 15.6 Protection against galvanic corrosion
15.7 Metal coverings of cables
15.8 Cable racks and cable trays <\/td>\n<\/tr>\n\n 35<\/td>\n 16 Lightning protection
16.1 Primary lightning protection system
16.2 Air terminals <\/td>\n<\/tr>\n\n 36<\/td>\n 16.3 Secondary lightning protection system
17 Communication <\/td>\n<\/tr>\n\n 37<\/td>\n 18 Test of completed installation
18.1 Inspections and tests
18.2 Insulation testing instruments <\/td>\n<\/tr>\n\n 38<\/td>\n 18.3 Insulation resistance
18.3.1 Wiring
18.3.2 Generators and motors
18.3.3 Switchboards, section boards and distribution boards
Table 6 \u2013 Test voltages <\/td>\n<\/tr>\n\n 39<\/td>\n 18.4 Generators
18.5 Switchgear
18.6 Lighting, heating and galley equipment
18.7 Communication systems
18.8 Emergency and safety systems <\/td>\n<\/tr>\n\n 40<\/td>\n 18.9 Earthing
18.10 Voltage drop
18.11 Requirements of international conventions and regulations
19 Documentation
19.1 General
19.2 Equipment
19.3 Testing <\/td>\n<\/tr>\n\n 41<\/td>\n 19.4 Maintenance <\/td>\n<\/tr>\n \n 42<\/td>\n Annex A (informative) Performance test
A.1 General
A.2 Motor
A.3 Statutory requirements
A.4 Interference
A.5 Batteries
A.6 Ventilation of battery installations <\/td>\n<\/tr>\n\n 43<\/td>\n Annex B (informative) Examples of cable termination
Figure B.1 \u2013 Equipment with through gland <\/td>\n<\/tr>\n\n 44<\/td>\n Figure B.2 \u2013 Equipment where earthing is required \u2013 with Ex d braid armour clamping gland <\/td>\n<\/tr>\n \n 45<\/td>\n Figure B.3 \u2013 Equipment where no earthing is required \u2013 with Ex d braid armourclamping gland \u2013 Termination of instrument cable <\/td>\n<\/tr>\n \n 46<\/td>\n Figure B.4 \u2013 Equipment where earthing is required \u2013 Ex d braidarmour clamping gland \u2013 Termination of power cable
Figure B.5 \u2013 Detail of heat shrink isolation between outer braid armourand electrostatic screen <\/td>\n<\/tr>\n\n 47<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Mobile and fixed offshore units. Electrical installations – Installation<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2019<\/td>\n 50<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":250353,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[552,2641],"product_tag":[],"class_list":{"0":"post-250348","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-260-99","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/250348","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/250353"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=250348"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=250348"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=250348"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}