{"id":250157,"date":"2024-10-19T16:29:55","date_gmt":"2024-10-19T16:29:55","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-pas-80005-32014\/"},"modified":"2024-10-25T11:43:08","modified_gmt":"2024-10-25T11:43:08","slug":"bsi-pd-iec-pas-80005-32014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-pas-80005-32014\/","title":{"rendered":"BSI PD IEC\/PAS 80005-3:2014"},"content":{"rendered":"
This PAS describes low voltage shore connection (LVSC) systems, on board the ship and on shore, to supply the ship with electrical power from shore.<\/p>\n
This PAS is applicable to the design, installation and testing of LVSC systems and addresses:<\/p>\n
LV shore distribution systems;<\/p>\n<\/li>\n
shore-to-ship connection and interface equipment;<\/p>\n<\/li>\n
transformers\/reactors;<\/p>\n<\/li>\n
semiconductor\/rotating convertors;<\/p>\n<\/li>\n
ship distribution systems; and<\/p>\n<\/li>\n
control, monitoring, interlocking and power management systems.<\/p>\n<\/li>\n<\/ul>\n
It does not apply to the electrical power supply during docking periods, e.g. dry docking and other out-of-service maintenance and repair.<\/p>\n<\/div>\n
Additional and\/or alternative requirements may be imposed by national administrations or the authorities within whose jurisdiction the ship is intended to operate and\/or by the owners or authorities responsible for a shore supply or distribution system.<\/p>\n
It is expected that LVSC systems will have practicable applications for ships requiring up to 1 MVA. Low-voltage shore connection systems not exceeding 250 A, with a maximum of 125 A per cable and not exceeding 300 V to earth are not covered by this PAS. High-voltage shore connection systems are covered by IEC\/ISO\/IEEE 80005\u20111<\/span> <\/span>.<\/p>\n Utility connections in port – Low Voltage Shore Connection (LVSC) Systems. General requirements<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 8<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 10<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 11<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 12<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 14<\/td>\n 4 General requirements
4.1 System description <\/td>\n<\/tr>\n\n 15<\/td>\n 4.2 Distribution system
4.2.1 General
4.2.2 Equipotential bonding
Figures
\n
Figure 1 \u2013 Block diagram of a typical LVSC system <\/td>\n<\/tr>\n\n 16<\/td>\n 4.3 Compatibility assessment before connection
4.4 LVSC system design and operation
4.4.1 System design
4.4.2 System operation <\/td>\n<\/tr>\n\n 17<\/td>\n 4.5 Personnel safety
4.6 Design requirements
4.6.1 General
4.6.2 Protection against moisture and condensation
4.6.3 Location and construction
4.6.4 Electrical equipment in hazardous areas <\/td>\n<\/tr>\n\n 18<\/td>\n 4.7 Electrical requirements
4.8 System study and calculations <\/td>\n<\/tr>\n\n 19<\/td>\n 4.9 Emergency shutdown including emergency-stop facilities <\/td>\n<\/tr>\n \n 20<\/td>\n 5 LV shore supply system requirements
5.1 Voltages and frequencies
Figure 2 \u2013 Phase sequence rotation \u2013 Positive direction <\/td>\n<\/tr>\n\n 21<\/td>\n 5.2 Quality of LV shore supply
Figure 3 \u2013 Balanced three-phase variables in time domain <\/td>\n<\/tr>\n\n 22<\/td>\n 6 Shore-side installation
6.1 General
6.2 System component requirements
6.2.1 Circuit-breaker and disconnector
6.2.2 Transformer
6.2.3 Neutral earthing resistor <\/td>\n<\/tr>\n\n 23<\/td>\n 6.2.4 Equipment earthing conductor bonding
6.3 Shore-to-ship electrical protection system <\/td>\n<\/tr>\n\n 24<\/td>\n 6.4 LV interlocking
6.4.1 General
6.4.2 Operating of the low-voltage (LV) circuit-breakers and disconnectors
6.5 Shore connection convertor equipment
6.5.1 General <\/td>\n<\/tr>\n\n 25<\/td>\n 6.5.2 Degree of protection
6.5.3 Cooling
6.5.4 Protection
7 Ship-to-shore connection and interface equipment
7.1 General <\/td>\n<\/tr>\n\n 26<\/td>\n 7.2 Cable management system
7.2.1 General
7.2.2 Monitoring of cable tension <\/td>\n<\/tr>\n\n 27<\/td>\n 7.2.3 Monitoring of the cable length
7.2.4 Connection conductor current unbalance protection
7.3 Plugs and socket-outlets
7.3.1 General <\/td>\n<\/tr>\n\n 29<\/td>\n Figure 4 \u2013 Safety loop circuit for one feeder (a) or three feeders (b), for LVSC system. <\/td>\n<\/tr>\n \n 30<\/td>\n 7.3.2 Pilot contacts
7.3.3 Earth contact
7.4 Ship-to-shore connection cable
7.5 Independent control and monitoring cable
7.6 Storage <\/td>\n<\/tr>\n\n 31<\/td>\n 8 Ship requirements
8.1 General
8.2 Ship electrical distribution system protection
8.2.1 Short-circuit protection
8.2.2 Earth fault protection, monitoring and alarm
8.3 Shore connection switchboard
8.3.1 General
8.3.2 Circuit-breaker and disconnector <\/td>\n<\/tr>\n\n 32<\/td>\n 8.3.3 Instrumentation and protection
8.4 On-board transformer
8.5 On-board receiving switchboard connection point
8.5.1 General
8.5.2 Circuit-breaker <\/td>\n<\/tr>\n\n 33<\/td>\n 8.5.3 Instrumentation
8.5.4 Protection <\/td>\n<\/tr>\n\n 34<\/td>\n 8.5.5 Operation of the circuit-breaker <\/td>\n<\/tr>\n \n 35<\/td>\n 8.6 Ship power restoration
9 LVSC system control and monitoring
9.1 General requirements
9.2 Load transfer via blackout
9.3 Load transfer via automatic synchronization
9.3.1 General <\/td>\n<\/tr>\n\n 36<\/td>\n 9.3.2 Protection requirements
10 Verification and testing
10.1 General <\/td>\n<\/tr>\n\n 37<\/td>\n 10.2 Initial tests of shore-side installation
10.2.1 General
10.2.2 Tests
10.3 Initial tests of ship-side installation
10.3.1 General
10.3.2 Tests <\/td>\n<\/tr>\n\n 38<\/td>\n 10.4 Tests at the first call at a shore supply point
10.4.1 General
10.4.2 Tests
11 Periodic tests and maintenance
11.1 General
11.2 Tests at repeated calls of a shore supply point
11.2.1 General
11.2.2 Verification <\/td>\n<\/tr>\n\n 39<\/td>\n 12 Documentation
12.1 General
12.2 System description
Figure 5 \u2013 Diagram showing the use of accessories <\/td>\n<\/tr>\n\n 40<\/td>\n Annex A (normative) Ship-to-shore connection cable1F
A.1 Rated voltage
A.2 Rated section \/ type
A.3 General design
A.3.1 General
A.3.2 Conductors <\/td>\n<\/tr>\n\n 41<\/td>\n A.3.3 Earth conductors
A.3.4 Pilot conductors
A.3.5 Cabling <\/td>\n<\/tr>\n\n 42<\/td>\n Annex B (normative) Ship-to-shore connection plugs, socket-outlets, ship connectors and ship inlets2F
B.1 Rated voltage
B.2 Rated type
B.3 General design
B.3.1 General <\/td>\n<\/tr>\n\n 43<\/td>\n B.3.2 Configuration
Figure B.1 \u2013 Connection with mobile cable reel
Figure B.2 \u2013 Connection with fixed cable reel
Table B.1 \u2013 Number of feeders function of power demand and voltage <\/td>\n<\/tr>\n\n 44<\/td>\n Annex C (normative) Additional requirements for Offshore Supply, Service and Working Ships
C.1 Scope
Figure C.1 \u2013 Example for general system layout <\/td>\n<\/tr>\n\n 45<\/td>\n Figure C.2 \u2013 Power plug and socket-outlet contact assignment <\/td>\n<\/tr>\n \n 46<\/td>\n Annex D (normative) Additional requirements for Container Ships
D.1 Scope
Figure D.1 \u2013 Example for general system layout <\/td>\n<\/tr>\n\n 47<\/td>\n Figure D.2 \u2013 Power plug and socket-outlet contact assignment <\/td>\n<\/tr>\n \n 48<\/td>\n Annex E (normative) Additional requirements for Tankers
E.1 Scope
Figure E.1 \u2013 Example for general system layout <\/td>\n<\/tr>\n\n 49<\/td>\n Figure E.2 \u2013 Power plug and socket pin assignment <\/td>\n<\/tr>\n \n 50<\/td>\n Figure E.3 \u2013 IS Barrier and cable properties (to be developed)
Figure E.4 \u2013 Safety loop circuit for LVSC system in tankers (to be developed) <\/td>\n<\/tr>\n\n 51<\/td>\n Annex F (normative) General operating procedures
Figure F.1 \u2013 LVSC general operating procedures forconnection a) and disconnection b) <\/td>\n<\/tr>\n\n 52<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2014<\/td>\n 56<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":250161,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[791,2641],"product_tag":[],"class_list":{"0":"post-250157","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-47-020-60","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/250157","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/250161"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=250157"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=250157"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=250157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}