{"id":197480,"date":"2024-10-19T12:34:11","date_gmt":"2024-10-19T12:34:11","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asa-s12-54-2011\/"},"modified":"2024-10-25T05:07:45","modified_gmt":"2024-10-25T05:07:45","slug":"asa-s12-54-2011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asa\/asa-s12-54-2011\/","title":{"rendered":"ASA S12.54 2011"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
15<\/td>\n | 1 Scope 1.1 General 1.2 Types of noise and noise sources 1.3 Test environment <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 1.4 Measurement uncertainty 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 4 Test environment 4.1 General 4.2 Criteria for background noise <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 4.3 Criterion for acoustic adequacy of test environment <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 5 Instrumentation 5.1 General 5.2 Calibration 6 Definition, location, installation, and operation of noise source under test 6.1 General 6.2 Auxiliary equipment <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.3 Noise source location 6.4 Mounting of the noise source <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 6.5 Installation and mounting conditions for moving noise sources 6.6 Operation of source during test <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 7 Reference box and measurement surface 7.1 Reference box <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 7.2 Measurement surface <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 8 Determination of sound power levels and sound energy levels 8.1 Microphone positions on the measurement surface <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 8.2 Determination of sound power levels <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 8.3 Determination of sound energy levels <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 8.4 Calculation of apparent directivity indices <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | 8.5 Calculation of apparent surface sound pressure level non-uniformity index 8.6 A-weighted sound power level and sound energy level 9 Measurement uncertainty 9.1 Methodology <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 9.2 Determination of . omc 9.3 Determination of . R0 <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 9.4 Typical upper bound values of . R0 <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 9.5 Total standard deviation . tot and expanded measurement uncertainty U 10 Information to be recorded 10.1 General 10.2 Noise source under test <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 10.3 Test environment ii \u00a9 2011 Acoustical Society of America\u2014All rights reserved. \n 10.4 Instrumentation 10.5 Acoustical data <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 11 Test report <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | Annex A (normative) Qualification procedures for the acoustic environment A.1 General A.2 Absolute comparison test <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | A.3 Determination of the environmental correction based on room absorption <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Annex B (normative) Microphone arrays on a hemispherical measurement surface B.1 Microphone positions and additional microphone positions <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | B.2 Microphone positions for sources adjacent to two reflecting planes B.3 Microphone positions for sources adjacent to three reflecting planes <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | B.4 Measurement paths <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | Annex C (normative) Microphone arrays on a parallelepiped measurement surface C.1 Microphone positions for sources mounted on one reflecting plane <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | C.2 Microphone positions for sources adjacent to two or three reflecting planes <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | Annex D (informative) Microphone arrays on a cylindrical measurement surface <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Annex E (normative) Calculation of A-weighted sound power levels and A-weighted sound energy levels \n from frequency band levels E.1 A-weighted sound power levels E.2 A-weighted sound energy levels E.3 Values of k and Ck for use in calculations <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex F (normative) Alternative microphone array on a hemispherical measurement surface for direct \n measurements of A-weighted sound pressure levels F.1 General F.2 Microphone positions on the measurement surface <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | Annex G (normative) Sound power level and sound energy level under reference meteorological \n conditions <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | Annex H (informative) Guidelines on the development of information on measurement uncertainty H.1 General H.2 Considerations on the total standard deviation . tot H.3 Considerations on . omc <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | H.4 Considerations on . R0 <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | H.5 Combined standard uncertainty H.6 Measurement uncertainty based on reproducibility data <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ANSI\/ASA S12.54-2011 \/ ISO 3744:2010 (R2016) American National Standard Acoustics – Determination of sound power levels and sound energy levels of noise sources using sound pressure – Engineering methods for an essentially free field over a reflecting plane (a nationally adopted international standard). This standard replaces ANSI S12.34-1988<\/b><\/p>\n |