Shopping Cart

No products in the cart.

BSI PD CEN/TR 17167:2023 – TC:2024 Edition

$280.87

Tracked Changes. Communication system for meters. Accompanying TR to EN 13757-2,-3 and -7, Examples and supplementary information

Published By Publication Date Number of Pages
BSI 2024 184
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Technical Report contains additional information to the requirements determined in EN 13757-2, EN 13757-3 and EN 13757-7, in particular examples for the implementation, Datagram examples secured by security mechanism of part 7 and additional non-normative requirements beyond meter communication itself.

PDF Catalog

PDF Pages PDF Title
92 undefined
98 1 Scope
2 Normative references
3 Terms and definitions
99 4 Symbols and abbreviations
4.1 Abbreviations
100 4.2 Symbols
5 Overview
102 Annex A (informative)Examples
A.1 General
A.2 Example for an RSP-UD
A.3 Example baud rate switch
103 A.4 Example application select with subcode
A.5 Writing data to a slave
104 A.6 Configuring M-Bus data output
A.6.1 General
105 A.6.2 Selection of data records with special data field
106 A.6.3 Selection of data records with object action code
A.6.4 Deselection of data records
107 A.7 FCB and selection
A.7.1 FCB-implementation slave
108 A.7.2 FCB-implementation master
109 A.8 Use of the fabrication number
110 Annex B (informative)Secondary search – Instructions for implementation of wildcard search
112 Annex C (informative)Consumer feedback for smart metering applications
C.1 General
C.2 Resolution of required values and accuracy of time information
C.2.1 General
C.2.2 Resolution in case of transmission of extra data points for power/flow rate
113 C.2.3 Resolution in case of non-transmission of extra data points for power/flow rate
C.2.3.1 General
114 C.2.3.2 Assumptions on time information for wireless connections
C.2.4 Transmission on request
115 Annex D (informative)Installation and registration
D.1 General
116 D.2 Registration with meter support
D.2.1 Introduction
D.2.2 RF-Link feedback
D.2.3 Registration feedback
D.3 Registration without meter support
118 Annex E (informative)M-Bus data container
E.1 Explanation
E.2 Definition
119 E.3 Example
120 Annex F (informative)Datagram examples for the M-Bus and the wM-Bus
F.1 Colour coding of the datagram examples
F.2 Security mode 5 example
124 F.3 Security mode 7 example
132 F.4 Security mode 8 example
136 F.5 Security Mode 9 example
F.5.1 General
137 F.5.2 Example input vectors
138 F.5.3 Example Mode 9 on SND-NR datagram
140 F.5.4 Example applying Mode 9 on RSP-UD datagram
143 F.6 Security mode 10 example
149 F.7 Special messages
F.7.1 Installation procedure with a special installation message
155 F.7.2 Send a command with an acknowledge
160 F.7.3 Request of the selected data
164 F.7.4 Reset of the link by a SND-NKE
166 F.7.5 Key transfer according SITP
171 F.7.6 Transfer secured application data according SITP
176 Annex G (informative)Descriptors
G.1 General
G.2 Storage descriptors
G.2.1 Storage interval descriptor
177 G.2.2 Storage range descriptor
G.3 Subunit descriptor
178 G.4 Tariff descriptor
179 G.5 Examples
G.5.1 Example: Storage descriptor
181 G.5.2 Example: Subunit descriptor
G.5.3 Example: Tariff descriptor
BSI PD CEN/TR 17167:2023 - TC
$280.87