Communication system for meters. Accompanying TR to EN 13757-2,-3 and -7, Examples and supplementary information
Published By | Publication Date | Number of Pages |
BSI | 2018 | 90 |
This Technical Report contains additional information to the requirements determined in EN 13757-2, EN 13757-3 and EN 13757-7, in particular examples for the implementation, Datagram examples secured by security mechanism of part 7 and additional non-normative requirements beyond meter communication itself.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
10 | 1 Scope 2 Normative references 3 Terms and definitions |
11 | 4 Symbols and abbreviations |
12 | 5 Overview |
14 | Annex A (informative)Examples A.1 General A.2 Example for a RSP-UD A.3 Example baud rate switch |
15 | A.4 Example application select with subcode A.5 Writing data to a slave |
16 | A.6 Configuring M-Bus data output A.6.1 General |
17 | A.6.2 Selection of data records with special data field |
18 | A.6.3 Selection of data records with object action code A.6.4 Deselection of data records |
19 | A.7 FCB and selection A.7.1 FCB-implementation slave A.7.2 FCB-implementation master |
20 | A.8 Use of the fabrication number |
22 | Annex B (informative)Secondary search – Instructions for implementation of wildcard search |
24 | Annex C (informative)Consumer feedback for smart metering applications C.1 General C.2 Resolution of required values and accuracy of time information C.2.1 General |
25 | C.2.2 Resolution in case of transmission of extra data points for power/flow rate C.2.3 Resolution in case of non-transmission of extra data points for power/flow rate C.2.3.1 General |
26 | C.2.3.2 Assumptions on time information for wireless connections C.2.4 Transmission on request |
27 | Annex D (informative)Installation and registration D.1 General |
28 | D.2 Registration with meter support D.2.1 Introduction D.2.2 RF-Link feedback D.2.3 Registration feedback D.3 Registration without meter support |
30 | Annex E (informative)M-Bus data container E.1 Explanation E.2 Definition |
31 | E.3 Example |
32 | Annex F (informative)Datagram examples for the M-Bus and the wM-Bus F.1 Colour coding of the datagram examples F.2 Security mode 5 example |
36 | F.3 Security mode 7 example |
44 | F.4 Security mode 8 example |
48 | F.5 Security Mode 9 example F.5.1 General F.5.2 Example input vectors |
49 | F.5.3 Example Mode 9 on SND-NR datagram |
51 | F.5.4 Example applying Mode 9 on RSP-UD datagram |
54 | F.6 Security mode 10 example |
59 | F.7 Special messages F.7.1 Installation procedure with a special installation message |
64 | F.7.2 Send a command with an acknowledge |
68 | F.7.3 Request of the selected data |
71 | F.7.4 Reset of the link by a SND-NKE |
73 | F.7.5 Key transfer according SITP |
78 | F.7.6 Transfer secured application data according SITP |
83 | Annex G (informative)Descriptors G.1 General G.2 Storage descriptors G.2.1 Storage interval descriptor |
84 | G.2.2 Storage range descriptor G.3 Subunit descriptor |
85 | G.4 Tariff descriptor |
86 | G.5 Examples G.5.1 Example: Storage descriptor |
88 | G.5.2 Example: Subunit descriptor G.5.3 Example: Tariff descriptor |