Shopping Cart

No products in the cart.

BSI PD CEN/TR 17167:2018

$215.11

Communication system for meters. Accompanying TR to EN 13757-2,-3 and -7, Examples and supplementary information

Published By Publication Date Number of Pages
BSI 2018 90
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This Technical Report contains additional information to the requirements determined in EN 13757-2, EN 13757-3 and EN 13757-7, in particular examples for the implementation, Datagram examples secured by security mechanism of part 7 and additional non-normative requirements beyond meter communication itself.

PDF Catalog

PDF Pages PDF Title
2 undefined
10 1 Scope
2 Normative references
3 Terms and definitions
11 4 Symbols and abbreviations
12 5 Overview
14 Annex A (informative)Examples
A.1 General
A.2 Example for a RSP-UD
A.3 Example baud rate switch
15 A.4 Example application select with subcode
A.5 Writing data to a slave
16 A.6 Configuring M-Bus data output
A.6.1 General
17 A.6.2 Selection of data records with special data field
18 A.6.3 Selection of data records with object action code
A.6.4 Deselection of data records
19 A.7 FCB and selection
A.7.1 FCB-implementation slave
A.7.2 FCB-implementation master
20 A.8 Use of the fabrication number
22 Annex B (informative)Secondary search – Instructions for implementation of wildcard search
24 Annex C (informative)Consumer feedback for smart metering applications
C.1 General
C.2 Resolution of required values and accuracy of time information
C.2.1 General
25 C.2.2 Resolution in case of transmission of extra data points for power/flow rate
C.2.3 Resolution in case of non-transmission of extra data points for power/flow rate
C.2.3.1 General
26 C.2.3.2 Assumptions on time information for wireless connections
C.2.4 Transmission on request
27 Annex D (informative)Installation and registration
D.1 General
28 D.2 Registration with meter support
D.2.1 Introduction
D.2.2 RF-Link feedback
D.2.3 Registration feedback
D.3 Registration without meter support
30 Annex E (informative)M-Bus data container
E.1 Explanation
E.2 Definition
31 E.3 Example
32 Annex F (informative)Datagram examples for the M-Bus and the wM-Bus
F.1 Colour coding of the datagram examples
F.2 Security mode 5 example
36 F.3 Security mode 7 example
44 F.4 Security mode 8 example
48 F.5 Security Mode 9 example
F.5.1 General
F.5.2 Example input vectors
49 F.5.3 Example Mode 9 on SND-NR datagram
51 F.5.4 Example applying Mode 9 on RSP-UD datagram
54 F.6 Security mode 10 example
59 F.7 Special messages
F.7.1 Installation procedure with a special installation message
64 F.7.2 Send a command with an acknowledge
68 F.7.3 Request of the selected data
71 F.7.4 Reset of the link by a SND-NKE
73 F.7.5 Key transfer according SITP
78 F.7.6 Transfer secured application data according SITP
83 Annex G (informative)Descriptors
G.1 General
G.2 Storage descriptors
G.2.1 Storage interval descriptor
84 G.2.2 Storage range descriptor
G.3 Subunit descriptor
85 G.4 Tariff descriptor
86 G.5 Examples
G.5.1 Example: Storage descriptor
88 G.5.2 Example: Subunit descriptor
G.5.3 Example: Tariff descriptor
BSI PD CEN/TR 17167:2018
$215.11