{"id":67247,"date":"2024-10-17T13:21:20","date_gmt":"2024-10-17T13:21:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d6195-2\/"},"modified":"2024-10-24T18:34:48","modified_gmt":"2024-10-24T18:34:48","slug":"astm-d6195-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d6195-2\/","title":{"rendered":"ASTM-D6195"},"content":{"rendered":"<\/p>\n

1.1 These test methods cover the determination of properties of a pressure-sensitive adhesive. These test methods are applicable to those adhesives that form a bond of measurable strength rapidly upon contact with another surface. Tack force may be measured as the force required to separate the adhesive from the adherend at the interface shortly after they have been brought into contact under a load equal only to the weight of the pressure-sensitive article (for example, tape, label, sticker, etc.) on a 1 in. 2<\/sup> contact area.<\/p>\n

1.2 The following test methods are included:<\/p>\n

1.2.1 Test Method A<\/span><\/span> (using Tensile Tester), and<\/p>\n

1.2.2 Test Method B<\/span><\/span> (using Loop Tack Tester).<\/p>\n

1.3 The values stated in inch-pound units are to be regarded as the standard because the industry standard width for pressure-sensitive tape is 1 inch. The values given in parentheses are for information purposes only.<\/p>\n

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Summary of Test Method
Significance and Use <\/td>\n<\/tr>\n
2<\/td>\nApparatus
Sample Preparation
Conditioning
Procedure
FIG. 1
FIG. 2 <\/td>\n<\/tr>\n
3<\/td>\nApparatus
Sample Preparation
Conditioning
FIG. 3
FIG. 4 <\/td>\n<\/tr>\n
4<\/td>\nProcedure
Calculation
Report
FIG. 5
FIG. 6 <\/td>\n<\/tr>\n
5<\/td>\nPrecision and Bias
Keywords
TABLE 1
TABLE 2 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

D6195-03e1 Standard Test Methods for Loop Tack<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2003<\/td>\n5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":67248,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2637],"product_tag":[],"class_list":{"0":"post-67247","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-astm","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/67247","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/67248"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=67247"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=67247"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=67247"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}