{"id":61439,"date":"2024-10-17T11:40:54","date_gmt":"2024-10-17T11:40:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d3916-3\/"},"modified":"2024-10-24T17:55:44","modified_gmt":"2024-10-24T17:55:44","slug":"astm-d3916-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d3916-3\/","title":{"rendered":"ASTM-D3916"},"content":{"rendered":"<\/p>\n
1.1 This test method describes a procedure for determining the tensile properties of pultruded, glass-fiber-reinforced thermosetting plastic rod of diameters ranging from 3.2 mm (1\/ 8 in.) to 25.4 mm (1 in.). Little test specimen preparation is required; however, reusable aluminum tab grip adapters (Fig. 1) of appropriate size are required to prevent premature failure of the specimens at the grips.<\/p>\n
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.<\/p>\n
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i> Specific hazards statements are given in Note 3 and Note 4.<\/p>\n
Note 1There is no known ISO equivalent to this test method.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Significance and Use Apparatus <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Test Specimens Conditioning Number of Test Specimens Procedure FIG. 1 <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Calculation TABLE 1 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Report Precision and Bias Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" D3916-02 Standard Test Method for Tensile Properties of Pultruded Glass-Fiber-Reinforced Plastic Rod<\/b><\/p>\n |