{"id":5970,"date":"2024-10-16T18:13:16","date_gmt":"2024-10-16T18:13:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d6143\/"},"modified":"2024-10-24T10:38:04","modified_gmt":"2024-10-24T10:38:04","slug":"astm-d6143","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d6143\/","title":{"rendered":"ASTM-D6143"},"content":{"rendered":"
Scope<\/strong><\/p>\n 1.1 This test method covers the procedure to determine the iron content of bisphenol A (4,4\u00b4-isopropylidenediphenol).<\/p>\n 1.2 This test method has a lower detection limit of 0.1 mg\/kg, and an upper limit of 10 mg\/kg of iron in bisphenol A. If the iron content is higher, it may be necessary to dilute the sample. A longer path length cell can also be used for better accuracy at lower Fe levels, as well as calibration within the range expected (for example, 0 to 1 mg\/kg versus 0 to 10 mg\/kg for samples expected to be in the 0 to 1 mg\/kg range.<\/p>\n 1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E 29.<\/p>\n 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.<\/p>\n 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limits prior to use.<\/i> For a specific hazard statement, see Section 8.<\/p>\n Keywords<\/strong><\/p>\n bisphenol A; iron<\/p>\n ICS Code<\/strong><\/p>\n ICS Number Code 71.040.40 (Chemical analysis)<\/p>\n DOI:<\/strong> 10.1520\/D6143-05<\/p>\n<\/div>\n D6143-05 Standard Test Method for Iron Content of Bisphenol A (4,4´ – Isopropylidenediphenol)<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Summary of Test Method
Significance and Use
Interferences
Apparatus
Reagents and Materials <\/td>\n<\/tr>\n\n 2<\/td>\n Hazards
Sampling and Handling
Calibration
Procedure
Calculation and Report
Precision and Bias
TABLE 1 <\/td>\n<\/tr>\n\n 3<\/td>\n Quality Guidelines
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2005<\/td>\n 3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":5971,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1000,2637],"product_tag":[],"class_list":{"0":"post-5970","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-71-040-40","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/5970","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/5971"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=5970"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=5970"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=5970"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}