{"id":444113,"date":"2024-10-20T08:36:08","date_gmt":"2024-10-20T08:36:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-c57-13-5-2019-3\/"},"modified":"2024-10-26T16:02:48","modified_gmt":"2024-10-26T16:02:48","slug":"ieee-c57-13-5-2019-3","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-c57-13-5-2019-3\/","title":{"rendered":"IEEE C57.13.5-2019"},"content":{"rendered":"
Revision Standard – Active. Single-phase instrument transformers of a nominal system voltage of 115 kV and above with capacitive insulation system for line-to-ground connection and for both indoor and outdoor application are discussed in this standard. This standard is intended for use as a supplement to IEEE Std C57.13-2016 and as a basis for performance and safety of equipment. Test sequences, criteria, methods, and documentation for the test are also described.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std C57.13.5\u2122-2019 Front cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 1.\u2002Overview 1.1\u2002Scope 1.2\u2002Purpose 1.3\u2002Word usage <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 2.\u2002Normative references 3.\u2002Definitions <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.\u2002General 4.1\u2002Insulation requirements <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 4.2\u2002Mineral oil requirements 4.3\u2002Requirements for accuracy and accuracy calibration systems 4.4\u2002Mechanical performance requirements <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 4.5\u2002Thermal performance requirements 4.6\u2002Ground shield requirements 4.7\u2002Dissolved gas and water content requirements for new oil-immersed transformers <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 4.8\u2002Endurance capability for fast high voltage transient 4.9\u2002Performance of internal arc protection 4.10\u2002Identification of test sample in the type test report 4.11\u2002Secondary short-circuit capability for voltage transformers <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 4.12\u2002Relaying current transformers having an anti-remanence gap 4.13\u2002Gas filling pressure and gas monitoring for gas-filled instrument transformers 5.\u2002Test conditions <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.\u2002Classification of tests 6.1\u2002Routine tests and test sequences <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.2\u2002Type tests and test sequences <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 6.3\u2002Special tests 7.\u2002Routine test procedures (applicable to instrument transformers) 7.1\u2002Verification of terminal markings and polarity 7.2\u2002Capacitance and dissipation factor test 7.3\u2002Applied voltage test on secondary windings <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 7.4\u2002Insulation resistance test on windings 7.5\u2002Lightning impulse voltage test on the primary winding <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | 7.6\u2002Power frequency voltage withstand test 7.7\u2002Partial discharge test <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 7.8\u2002Dissolved gas and water content analysis for oil-immersed transformers (of a nominal system voltage of 345 kV and above) 7.9\u2002Sealing test 7.10\u2002Ground shield check <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 7.11\u2002Tests on the mineral oil 7.12\u2002Inspection and routine pressure test for enclosure of gas-filled instrument transformers 8.\u2002Routine test procedures (applicable to current transformers) 8.1\u2002Inter-turn over-voltage test <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 8.2\u2002Accuracy test for the metering rated current transformers 8.3\u2002Resistance measurement of relaying rated secondary windings <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 8.4\u2002Performance characteristics of relaying current transformers <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 9.\u2002Routine test procedures (applicable to voltage transformers) 9.1\u2002Applied voltage test on the neutral terminal 9.2\u2002Accuracy test 9.3\u2002Excitation characteristics with respect to rated voltage factor <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 9.4\u2002Resistance measurement of windings 10.\u2002Type test procedures (applicable to instrument transformers) 10.1\u2002Dissolved gas and water content analysis 10.2\u2002Mechanical test <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 10.3\u2002Lightning impulse voltage test on the primary winding <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 10.4\u2002Switching impulse voltage test on the primary winding \u2013 wet <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 10.5\u2002External radio influence voltage (RIV) test 10.6\u2002Power frequency voltage withstand test \u2013 wet 10.7\u2002Power frequency voltage withstand\/partial discharge test – dry <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 10.8\u2002Temperature rise test <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 10.9\u2002Short-time mechanical and thermal rating test <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | 10.10\u2002Accuracy performance test 10.11\u2002Creepage distance measurement <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | 10.12\u2002Leakage test at low temperature for gas-filled instrument transformers 10.13\u2002Burst test on enclosure for gas-filled instrument transformers 11.\u2002Type test procedure (applicable to current transformers) 11.1\u2002Secondary open-circuit voltage withstand test <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 12.\u2002Special test procedures 12.1\u2002Endurance chopped wave test <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 12.2\u2002Internal arc test <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 12.3\u2002Seismic qualification 13.\u2002Identification of test sample in the type test report <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | 13.1\u2002Document package related to transformer type <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex\u00a0A (normative) Test code A.1\u2002Temperature rise test <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | A.2\u2002Leakage test at low temperature for gas-filled instrument transformers <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | A.3\u2002Endurance chopped wave test <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Annex\u00a0B (normative) Validity of type test reports and guidance for reviewing the design comparison report for the modified design B.1\u2002Validity of type test reports B.2\u2002Guidance of reviewing the comparison report <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Annex\u00a0C (normative) Current transformers used for the detection of unbalance current of capacitor banks C.1\u2002General C.2\u2002Definition C.3\u2002General requirements <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | C.4\u2002Specific requirements <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | Annex\u00a0D (normative) Gas tightness D.1\u2002Specification D.2\u2002Testing D.3\u2002Cumulative test method and calibration procedure <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | D.4\u2002Time between replenishments <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Annex\u00a0E (informative) Dielectric tests performed at an altitude of 1000 m or less for instrument transformers designed for installation at altitudes greater than 1000 m <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | Annex\u00a0F (informative) Dielectric tests, oil sampling, and other related measurements in the field <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Annex\u00a0G (informative) Internal arc protection for instrument transformers <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Annex\u00a0H (informative) Rated voltage factor <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | Annex\u00a0I (informative) Current transformers having transient performance requirements <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | Annex\u00a0J (informative) Electrical endurance test, explanatory note <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex\u00a0K (informative) Bibliography <\/td>\n<\/tr>\n | ||||||