{"id":443599,"date":"2024-10-20T08:33:45","date_gmt":"2024-10-20T08:33:45","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ashrae-standard-205-2023\/"},"modified":"2024-10-26T16:00:07","modified_gmt":"2024-10-26T16:00:07","slug":"ashrae-standard-205-2023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ashrae\/ashrae-standard-205-2023\/","title":{"rendered":"ASHRAE Standard 205 2023"},"content":{"rendered":"

Standard 205 defines common data models and serialization formats for facility equipment performance data, allowing automated exchange among data sources (manufacturers), simulation models, and other engineering applications. The main body of the standard provides rules and definitions used for generating representation specifications, including data groups that are common to all representation specifications, requirements for the structure of a representation specification, common definitions such as abbreviations, and informative material. This portion of the main body can be viewed as a meta-standard in that it specifies how to produce a representation specification. The Standard 205 JSON schema (with online access) provides a machine-processable equivalent statement of the data model, allowing automated reading, writing, and validation of data files. The formats and procedures specified by Standard 205 are developed under ASHRAE and ANSI consensus processes with participation of equipment manufacturers, application software developers, and engineering practitioners. The intent is that all data publishers write common-format data files and all application software include procedures to read files using that format. Standard procedures will improve the accuracy and consistency of model results relative to the mix of correlation and application-specific approaches traditionally used. Standard 205 does not define or restrict distribution schemes for representation files. Data publishers may establish distribution policies that fit their business needs.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nANSI\/ASHRAE Standard 205-2023 <\/td>\n<\/tr>\n
3<\/td>\nContents <\/td>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\n1. Purpose
2. Scope <\/td>\n<\/tr>\n
8<\/td>\n3. Definitions <\/td>\n<\/tr>\n
9<\/td>\n4. Representation Content
5. Data Model Content
5.1 Data Group Composition
5.2 Data Element Attributes
5.3 Data Type Definitions <\/td>\n<\/tr>\n
11<\/td>\n5.4 Units <\/td>\n<\/tr>\n
12<\/td>\n5.5 Constraints <\/td>\n<\/tr>\n
13<\/td>\n5.6 Required Data Elements <\/td>\n<\/tr>\n
14<\/td>\n5.7 Common Enumerations <\/td>\n<\/tr>\n
15<\/td>\n5.8 Common Data Groups <\/td>\n<\/tr>\n
17<\/td>\n6. Representation Specification Structure
6.1 Identification and History
6.2 Scope and Description <\/td>\n<\/tr>\n
18<\/td>\n6.3 Data Model <\/td>\n<\/tr>\n
20<\/td>\n6.4 Verification Rules <\/td>\n<\/tr>\n
22<\/td>\n6.5 Publishing Rules
6.6 Application Rules
6.7 References
6.8 Example(s)
7. Data Model Naming Conventions
7.1 Allowed Characters <\/td>\n<\/tr>\n
23<\/td>\n7.2 Data Group Names
7.3 Data Element Names
7.4 Enumeration Names
7.5 Enumerator Names
7.6 Abbreviations <\/td>\n<\/tr>\n
24<\/td>\n7.7 Pre-Existing Names (Informative)
7.8 Naming Guidelines (Informative) <\/td>\n<\/tr>\n
25<\/td>\n8. Physical Properties
8.1 Psychrometric Properties of Moist Air
8.2 Liquid Properties
8.3 Refrigerant Properties
9. Data Quality, Integrity, Access, and Accuracy
9.1 Data Quality
9.2 Data Integrity
9.3 Data Access
9.4 Data Accuracy (Informative)
10. References <\/td>\n<\/tr>\n
27<\/td>\nInformative Appendix A: Example Performance Map Representation <\/td>\n<\/tr>\n
29<\/td>\nRS0001 Liquid-Cooled Chiller
Identification and History
Scope and Description
Data Model <\/td>\n<\/tr>\n
45<\/td>\nVerification Rules <\/td>\n<\/tr>\n
47<\/td>\nPublishing Rules
Application Rules
References
Example (Informative) <\/td>\n<\/tr>\n
49<\/td>\nRS0002 Unitary Cooling Air-Conditioning Equipment
Identification and History
Scope and Description
Data Model <\/td>\n<\/tr>\n
57<\/td>\nVerification Rules
Publishing Rules
Application Rules
References <\/td>\n<\/tr>\n
58<\/td>\nExample (Informative) <\/td>\n<\/tr>\n
59<\/td>\nRS0003 Fan Assembly
Identification and History
Scope and Description <\/td>\n<\/tr>\n
60<\/td>\nData Model <\/td>\n<\/tr>\n
68<\/td>\nVerification Rules <\/td>\n<\/tr>\n
69<\/td>\nPublishing Rules
Application Rules
References
Example (Informative) <\/td>\n<\/tr>\n
71<\/td>\nRS0004 Air-to-Air Direct Expansion System
Identification and History
Scope and Description
Data Model <\/td>\n<\/tr>\n
77<\/td>\nVerification Rules <\/td>\n<\/tr>\n
78<\/td>\nPublishing Rules
Application Rules
References
Example (Informative) <\/td>\n<\/tr>\n
79<\/td>\nRS0005 Motor
Identification and History
Scope and Description <\/td>\n<\/tr>\n
80<\/td>\nData Model <\/td>\n<\/tr>\n
83<\/td>\nVerification Rules <\/td>\n<\/tr>\n
84<\/td>\nPublishing Rules
Application Rules
References
Example (Informative) <\/td>\n<\/tr>\n
85<\/td>\nRS0006 Electronic Motor Drive
Identification and History
Scope and Description
Data Model <\/td>\n<\/tr>\n
89<\/td>\nVerification Rules
Publishing Rules
Application Rules
References
Example (Informative) <\/td>\n<\/tr>\n
91<\/td>\nRS0007 Mechanical Drive
Identification and History
Scope and Description
Data Model <\/td>\n<\/tr>\n
95<\/td>\nVerification Rules
Publishing Rules
Application Rules
References
Example (Informative) <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASHRAE Standard 205-2023 — Representation of Performance Data for HVAC&R and Other Facility Equipment (ANSI Approved)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASHRAE<\/b><\/a><\/td>\n2023<\/td>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":443603,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2719],"product_tag":[],"class_list":{"0":"post-443599","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ashrae","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/443599","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/443603"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=443599"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=443599"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=443599"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}