{"id":441008,"date":"2024-10-20T08:18:53","date_gmt":"2024-10-20T08:18:53","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-ufc-volume1-1997\/"},"modified":"2024-10-26T15:31:10","modified_gmt":"2024-10-26T15:31:10","slug":"icc-ufc-volume1-1997","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-ufc-volume1-1997\/","title":{"rendered":"ICC UFC Volume1 1997"},"content":{"rendered":"

The Uniform Fire Code (UFC) is the United States premier model fire code. Since its initiation in 1971, the code has become internationally recognized for its role in setting the pace of fire prevention, fire protection and public safety. Fire codes represent one of today’s most rapidly changing regulatory arenas. New challenges presented by hazardous materials, flammable and combustible liquids, explosives, high-piled combustible storage, aerosol product storage and building operations are among the many issues shaping the future of fire prevention, fire protection and public safety. In addition, fire codes have evolved far beyond their traditional roles as maintenance codes, now addressing many issues related to new construction and special hazards in buildings. As a model code developed through a consensus code development process, the Uniform Fire Code provides jurisdictions with an opportunity to adopt a fire code which is comprehensive, up-to-date and consistent with codes of other jurisdictions. Adoption of the Uniform Fire Code also relieves jurisdictions from the burdensome process of independently developing regulations.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n1997 UNIFORM FIRE CODE VOLUME 1 COVER <\/td>\n<\/tr>\n
3<\/td>\nCOPYRIGHT NOTICE <\/td>\n<\/tr>\n
4<\/td>\nPREFACE <\/td>\n<\/tr>\n
5<\/td>\nABOUT THE INTERNATIONAL FIRE CODE INSTITUTE <\/td>\n<\/tr>\n
6<\/td>\nCODES AND RELATED PUBLICATIONS <\/td>\n<\/tr>\n
7<\/td>\nTECHNICAL REFERENCES AND EDUCATIONAL MATERIALS <\/td>\n<\/tr>\n
8<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
14<\/td>\nADOPTION ORDINANCE <\/td>\n<\/tr>\n
16<\/td>\nARTICLE 1 ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 RETROACTIVE SECTION 102 RETROACTIVE APPLICATION TO EXISTING CONDITIONS
SECTION 103 INSPECTION AND ENFORCEMENT <\/td>\n<\/tr>\n
18<\/td>\nSECTION 104 CONTROL AND INVESTIGATION OF EMERGENCY SCENES <\/td>\n<\/tr>\n
19<\/td>\nSECTION 105 PERMITS <\/td>\n<\/tr>\n
21<\/td>\nTABLE 105 A <\/td>\n<\/tr>\n
22<\/td>\nTABLE 105 B
TABLE 105 C <\/td>\n<\/tr>\n
23<\/td>\nARTICLE 2 DEFINITONS AND ABBREVIATONS
SECTION 201 GENERAL
SECTION 202 – A <\/td>\n<\/tr>\n
24<\/td>\nSECTION 203 – B <\/td>\n<\/tr>\n
25<\/td>\nSECTION 204 – C <\/td>\n<\/tr>\n
27<\/td>\nSECTION 205 – D
SECTION 206 – E <\/td>\n<\/tr>\n
28<\/td>\nSECTION 207 – F <\/td>\n<\/tr>\n
29<\/td>\nSECTION 208 – G <\/td>\n<\/tr>\n
30<\/td>\nSECTION 209 – H <\/td>\n<\/tr>\n
31<\/td>\nSECTION 210 – I
SECTION 211 – J
SECTION 212 – K
SECTION 213 – L <\/td>\n<\/tr>\n
32<\/td>\nSECTION 214 – M
SECTION 215 – N
SECTION 216 – O <\/td>\n<\/tr>\n
36<\/td>\nSECTION 217 – P <\/td>\n<\/tr>\n
37<\/td>\nSECTION 218 – Q
SECTION 219 – R
SECTION 220 – S <\/td>\n<\/tr>\n
39<\/td>\nSECTION 221 – T
SECTION 222 – U <\/td>\n<\/tr>\n
40<\/td>\nSECTION 223 – V
SECTION 224 – W
SECTION 225 – X
SECTION 226 – Y
Section 227 – Z <\/td>\n<\/tr>\n
41<\/td>\nARTICLE 9 FIRE DEPARTMENT ACCESS AND WATER SUPPLY
SECTION 901 GENERAL
SECTION 902 FIRE DEPARTMENT ACCESS <\/td>\n<\/tr>\n
42<\/td>\nSECTION 903 WATER SUPPLIES AND FIRE HYDRANTS <\/td>\n<\/tr>\n
44<\/td>\nARTICLE 10 FIRE-PROTECTION SYSTEMS AND EQUIPMENT
SECTION 1001 GENERAL <\/td>\n<\/tr>\n
45<\/td>\nSECTION 1002 PORTABLE FIRE EXTINGUISHERS
SECTION 1003 FIRE-EXTINGUISHING SYSTEMS <\/td>\n<\/tr>\n
47<\/td>\nTABLE 1003.2.6.3
SECTION 1004 STANDPIPES <\/td>\n<\/tr>\n
48<\/td>\nSECTION 1005 BASEMENT PIPE INLETS
SECTION 1006 PROTECTION OF COMMERCIAL COOKING OPERATIONS <\/td>\n<\/tr>\n
49<\/td>\nSECTION 1007 FIRE ALARM SYSTEMS <\/td>\n<\/tr>\n
53<\/td>\nTABLE 1004-A <\/td>\n<\/tr>\n
54<\/td>\nARTICLE 11 GENERAL SAFETY PRECAUTIONS
SECTION 1101 GENERAL
SECTION 1102 INCINERATORS, OPEN BURNING AND COMMERCIAL BARBECUE PITS <\/td>\n<\/tr>\n
55<\/td>\nSECTION 1103 COMBUSTIBLE MATERIALS <\/td>\n<\/tr>\n
56<\/td>\nSECTION 1104 PARADE FLOATS
SECTION 1105 ASPHALT KETTLES
SECTION 1106 GAS METERS AND PIPING
SECTION 1107 HEAT-PRODUCING APPLIANCES <\/td>\n<\/tr>\n
57<\/td>\nSECTION 1108 POWERED INDUSTRIAL TRUCKS
SECTION 1109 CONTROL OF SOURCES OF IGNITION <\/td>\n<\/tr>\n
58<\/td>\nSECTION 1110 VACANT BUILDINGS
SECTION 1111 MAINTENANCE OF FIRE-RESISTIVE CONSTRUCTION
SECTION 1112 MAINTENANCE OF INTERIOR WALL AND CEILING FINISHES
SECTION 1113 FLOOR OPENINGS <\/td>\n<\/tr>\n
59<\/td>\nARTICLE 12 MAINTENANCE OF MEANS OF EGRESS AND EMERGENCY ESCAPES
SECTION 1201 GENERAL
SECTION 1202 ADEQUACY OF MEANS OF EGRESS IN EXISTING OCCUPANCIES
SECTION 1203 MEANS OF EGRESS OBSTRUCTIONS
SECTION 1204 AISLES
SECTION 1205 FIRE ESCAPE
SECTION 1206 EMERGENCY ESCAPES
SECTION 1207 DOORS <\/td>\n<\/tr>\n
60<\/td>\nSECTION 1208 GATES AND BARRIERS
SECTION 1209 CORRIDORS
SECTION 1210 STAIRWAYS AND RAMPS
SECTION 1211 MEANS OF EGRESS ILLUMINATION
SECTION 1212 MEANS OF EGRESS IDENTIFICATION <\/td>\n<\/tr>\n
61<\/td>\nSECTION 1213 DISCHARGE, DISPERSAL AND REFUGE <\/td>\n<\/tr>\n
62<\/td>\nARTICLE 13 EMERGENCY PROCEDURES
SECTION 1301 GENERAL
SECTION 1302 REPORTING OF EMERGENCIES AND FALSE ALARMS
SECTION 1303 EMERGENCY PLANS AND PROCEDURES <\/td>\n<\/tr>\n
64<\/td>\nARTICLE 24 AIRPORTS, HELIPORTS AND HELISTOPS
SECTION 2401 GENERAL
SECTION 2402 FUELING AND DEFUELING <\/td>\n<\/tr>\n
66<\/td>\nSECTION 2403 HELIPORTS AND HELISTOPS <\/td>\n<\/tr>\n
67<\/td>\nARTICLE 25 PLACES OF ASSEMBLY
SECTION 2501 GENERAL <\/td>\n<\/tr>\n
69<\/td>\nTABLE 2501-A
TABLE 2501-B <\/td>\n<\/tr>\n
70<\/td>\nSECTION 2502 REVIEWING STANDS, GRANDSTANDS, BLEACHERS, AND FOLDING AND TELESCOPING SEATING <\/td>\n<\/tr>\n
71<\/td>\nSECTION 2503 SECURING OF CHAIRS
SECTION 2504 OUTDOOR CARNIVALS AND FAIRS
SECTION 2505 LIQUID- AND GAS-FUELED VEHICLES AND EQUIPMENT <\/td>\n<\/tr>\n
73<\/td>\nARTICLE 26 BOWLING ALLEYS
SECTION 2601 SCOPE
SECTION 2602 PERMITS
SECTION 2603 ALLEY RESURFACING AND REFINISHING
SECTION 2604 PIN-REFINISHING ROOMS <\/td>\n<\/tr>\n
74<\/td>\nARTICLE 27 CELLULOSE NITRATE PLASTICS (PROXYLIN), STORAGE AND HANDLING
SECTION 2701 SCOPE
SECTION 2702 DEFINITIONS
SECTION 2703 PERMITS
SECTION 2704 DISPLAY OF PLASTICS
SECTION 2705 STORAGE AND HANDLING
SECTION 2706 FIRE-PROTECTION EQUIPMENT
SECTION 2707 SOURCES OF IGNITION <\/td>\n<\/tr>\n
75<\/td>\nARTICLE 28 STORAGE AND HANDLING OF COMBUSTIBLE FIBERS
SECTION 2801 SCOPE
SECTION 2802 DEFINITIONS
SECTION 2803 PERMITS
SECTION 2804 LOOSE STORAGE
TABLE 2804-A
SECTION 2805 BALED STORAGE
SECTION 2806 STORAGE OF AGRICULTURAL PRODUCTS
SECTION 2807 DUST-COLLECTING SYSTEM <\/td>\n<\/tr>\n
76<\/td>\nARTICLE 29 REPAIR GARAGES
SECTION 2901 GENERAL
SECTION 2902 REPAIR GARAGES FOR LIQUID-FUELED AND LPG-FUELED VEHICLES
SECTION 2903 REPAIR GARAGES FOR NATURAL GAS- AND HYDROGEN-FUELED VEHICLES <\/td>\n<\/tr>\n
78<\/td>\nARTICLE 30 WOOD PRODUCTS
SECTION 3001 SCOPE
SECTION 3002 DEFINITIONS
SECTION 3003 PERMITS
SECTION 3004 GENERAL REQUIREMENTS
SECTION 3005 LOG STORAGE AREAS
SECTION 3006 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL IN ASSOCIATION WITH TIMBER AND LUMBER PRODUCTION FACILITIES
SECTION 3007 PLYWOOD AND VENEER MILLS <\/td>\n<\/tr>\n
79<\/td>\nSECTION 3008 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT IN ASSOCIATION WITH YARD WASTE AND RECYCLING FACILITIES
SECTION 3009 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS <\/td>\n<\/tr>\n
80<\/td>\nARTICLE 31 NOT USED <\/td>\n<\/tr>\n
81<\/td>\nARTICLE 32 TEMPORARY MEMBRANE STRUCTURES, TENTS AND CANOPIES
SECTION 3201 SCOPE
SECTION 3202 DEFINITIONS
SECTION 3203 PERMITS
SECTION 3204 USE PERIOD
SECTION 3205 ACCESS, LOCATION AND PARKING
SECTION 3206 STRUCTURAL STABILITY
SECTION 3207 FLAME RESISTANCE
SECTION 3208 PORTABLE FIRE EXTINGUISHERS
SECTION 3209 MAXIMUM OCCUPANT LOAD
SECTION 3210 SEATING ARRANGEMENTS
SECTION 3211 MEANS OF EGRESS <\/td>\n<\/tr>\n
82<\/td>\nSECTION 3212 MAINTENANCE OF MEANS OF EGRESS
SECTION 3213 MEANS OF EGRESS ILLUMINATION
SECTION 3214 EXIT SIGNS
SECTION 3215 SOURCES OF IGNITION
SECTION 3216 COOKING AND HEATING
SECTION 3217 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 3218 DISPLAY OF MOTOR VEHICLES
SECTION 3219 GENERATORS
SECTION 3220 STANDBY PERSONNEL <\/td>\n<\/tr>\n
83<\/td>\nSECTION 3221 HOUSEKEEPING
TABLE 3211-A <\/td>\n<\/tr>\n
84<\/td>\nARTICLE 33 CELLULOSE NITRATE MOTION PICTURE FILM
SECTION 3301 SCOPE
SECTION 3302 PERMITS
SECTION 3303 BUILDINGS
SECTION 3304 STORAGE AND HANDLING <\/td>\n<\/tr>\n
85<\/td>\nARTICLE 34 AUTOMOBILE WRECKING YARDS
SECTION 3401 SCOPE
SECTION 3402 DEFINITIONS
SECTION 3403 PERMITS
SECTION 3404 FIRE APPARATUS ACCESS ROADS
SECTION 3405 WELDING AND CUTTING
SECTION 3406 HOUSEKEEPING
SECTION 3407 FIRE PROTECTION
SECTION 3408 TIRES
SECTION 3409 BURNING OPERATIONS
SECTION 3410 MOTOR VEHICLE FLUIDS AND HAZARDOUS MATERIALS <\/td>\n<\/tr>\n
86<\/td>\nARTICLE 35 COVERED MALL BUILDINGS
SECTION 3501 SCOPE
SECTION 3502 DEFINITIONS
SECTION 3503 PERMITS
SECTION 3504 GENERAL REQUIREMENTS
SECTION 3505 TEMPORARY STRUCTURES
SECTION 3506 TEMPORARY PLACES OF ASSEMBLY <\/td>\n<\/tr>\n
87<\/td>\nARTICLE 36 DRY CLEANING
SECTION 3601 GENERAL
SECTION 3602 DRY CLEANING WITH NONCOMBUSTIBLE LIQUIDS EXCEPT FOR LIMITED-ACCESS SPOTTING OPERATIONS <\/td>\n<\/tr>\n
88<\/td>\nSECTION 3603 DRY CLEANING WITH FLAMMABLE AND COMBUSTIBLE LIQUIDS <\/td>\n<\/tr>\n
91<\/td>\nARTICLE 45 APPLICATION OF FLAMMABLE FINISHES
SECTION 4501 GENERAL
SECTION 4502 SPRAY FINISHING <\/td>\n<\/tr>\n
93<\/td>\nTABLE 4502.A MINIMUM THICKNESS OF EXHAUST DUCTS <\/td>\n<\/tr>\n
94<\/td>\nSECTION 4503 DIPPING OPERATIONS <\/td>\n<\/tr>\n
96<\/td>\nSECTION 4504 ELECTROSTATIC APPARATUS
SECTION 4505 POWDER COATING <\/td>\n<\/tr>\n
97<\/td>\nSECTION 4506 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS <\/td>\n<\/tr>\n
98<\/td>\nARTICLE 46 FRUIT-RIPENING PROCESSES
SECTION 4601 SCOPE
SECTION 4602 PERMITS
SECTION 4603 USE OF ETHYLENE
SECTION 4604 ELECTRICAL EQUIPMENT AND ILLUMINATION
SECTION 4605 HEATING
SECTION 4606 SOURCES OF IGNITION
SECTION 4607 HOUSEKEEPING <\/td>\n<\/tr>\n
99<\/td>\nARTICLE 47 FUMIGATION AND THERMAL INSECTICIDAL FOGGING
SECTION 4701 SCOPE
SECTION 4702 PERMITS
SECTION 4703 SOURCES OF IGNITION
SECTION 4704 NOTIFICATION OF FUMIGATION
SECTION 4705 BREATHING APPARATUS
SECTION 4706 WATCH DURING FUMIGATION
SECTION 4707 SEALING OF BUILDINGS
SECTION 4708 WARNING SIGNS
SECTION 4709 VENTING AND CLEANUP
SECTION 4710 THERMAL INSECTICIDAL FOGGING LIQUIDS
SECTION 4711 CARBON DISULFIDE AND HYDROGEN CYANIDE <\/td>\n<\/tr>\n
100<\/td>\nTABLE 4703-A CHARACTERISTICS OF SELECTED FUMIGANTS <\/td>\n<\/tr>\n
101<\/td>\nARTICLE 48 MAGNESIUM
SECTION 4801 SCOPE
SECTION 4802 PERMITS
SECTION 4803 STORAGE OF PIGS, INGOTS AND BILLETS
SECTION 4804 MELTING POTS
SECTION 4805 STORAGE OF MAGNESIUM ARTICLE IN FOUNDRIES AND PROCESSING PLANTS
SECTION 4806 HEAT-TREATING OVENS
SECTION 4807 MAGNESIUM PROCESSING OPERATIONS
SECTION 4808 FIRE-EXTINGUISHING MATERIALS
SECTION 4809 STORAGE OF MAGNESIUM ARTICLES
SECTION 4810 FINE MAGNESIUM SCRAP <\/td>\n<\/tr>\n
103<\/td>\nARTICLE 49 HOT WORK
SECTION 4901 – GENERAL <\/td>\n<\/tr>\n
104<\/td>\nSECTION 4902 – FIXED HOT-WORK AREAS <\/td>\n<\/tr>\n
105<\/td>\nARTICLE 50 MANUFACTURE OF ORGANIC COATINGS
SECTION 5001 – SCOPE
SECTION 5002 – DEFINITIONS
SECTION 5003 – PERMITS
SECTION 5004 – PROCESS BUILDINGS
SECTION 5005 – STORAGE OF RAW MATERIALS AND FINISHED PRODUCTS
SECTION 5006 – SPILL CONTROL AND SECONDARY CONTAINMENT
SECTION 5007 – PROCESS MILLS, MIXERS AND KETTLES <\/td>\n<\/tr>\n
106<\/td>\nSECTION 5008 – PROCESS PIPING
SECTION 5009 – TRANSFER OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN PROCESS AREAS
SECTION 5010 – RAW MATERIALS IN PROCESS AREAS
SECTION 5011 – ELECTRICAL EQUIPMENT
SECTION 5012 – PROTECTION FROM STATIC ELECTRICITY AND LIGHTNING <\/td>\n<\/tr>\n
107<\/td>\nSECTION 5013 – FIRE PROTECTION
SECTION 5014 – MAINTENANCE <\/td>\n<\/tr>\n
108<\/td>\nARTICLE 51 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 5101 – GENERAL <\/td>\n<\/tr>\n
111<\/td>\nSECTION 5102 – STORAGE
SECTION 5103 – USE AND HANDLING <\/td>\n<\/tr>\n
113<\/td>\nTABLE 5102-A – QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H, DIVISION 6 OCCUPANCY <\/td>\n<\/tr>\n
114<\/td>\nTABLE 5102-B – MAXIMUM QUANTITIES OF HPM AT A WORKSTATION
TABLE 5102-C – MINIMUM SEPARATION OF HPM1,2 <\/td>\n<\/tr>\n
115<\/td>\nARTICLE 52 MOTOR VEHICLE FUEL-DISPENSING STATIONS
SECTION 5201 – GENERAL <\/td>\n<\/tr>\n
116<\/td>\nSECTION 5202 – FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR VEHICLE FUEL-DISPENSING STATIONS <\/td>\n<\/tr>\n
122<\/td>\nTABLE 5202.6-A – CLASS I LOCATIONS1 <\/td>\n<\/tr>\n
123<\/td>\nFIGURE 5202.6-A – CLASSIFIED LOCATIONS ADJACENT TO DISPENSERS AS DETAILED IN TABLE 5202.6-A <\/td>\n<\/tr>\n
124<\/td>\nSECTION 5203 – LIQUEFIED PETROLEUM GAS
SECTION 5204 – COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING STATIONS <\/td>\n<\/tr>\n
125<\/td>\nTABLE 5204.10-A – SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG <\/td>\n<\/tr>\n
126<\/td>\nSPECIAL EQUIPMENT ARTICLE 61 OIL-BURNING EQUIPMENT
SECTION 6101 – SCOPE
SECTION 6102 – GENERAL
SECTION 6103 – PERMITS
SECTION 6104 – ELECTRICAL WIRING AND EQUIPMENT
SECTION 6105 – FUEL OIL
SECTION 6106 – PORTABLE UNVENTED OIL-BURNING APPLIANCES <\/td>\n<\/tr>\n
127<\/td>\nARTICLE 62 INDUSTRIAL BAKING AND DRYING OVENS
SECTION 6201 – SCOPE
SECTION 6202 – PERMITS AND PLANS
SECTION 6203 – LOCATION AND CONSTRUCTION
SECTION 6204 – VENTILATION
SECTION 6205 – SAFETY CONTROLS <\/td>\n<\/tr>\n
128<\/td>\nARTICLE 63 REFRIGERATION
SECTION 6301 – SCOPE
SECTION 6302 – CLASSIFICATION
SECTION 6303 – DEFINITIONS
SECTION 6304 – PERMITS AND PLANS
SECTION 6305 – INSTALLATION AND MAINTENACE
SECTION 6306 – ACCESS
SECTION 6307 – EMERGENCY CONTROL BOX
SECTION 6308 – TREATMENT AND FLARING SYSTEMS FOR DISCHARGE
SECTION 6309 – AMMONIA DISCHARGE <\/td>\n<\/tr>\n
129<\/td>\nSECTION 6310 – REFRIGERATION MACHINERY ROOMS
SECTION 6311 – REFRIGERATION MACHINERY ROOM VENTILATION <\/td>\n<\/tr>\n
130<\/td>\nSECTION 6312 – REFRIGERATED PROCESS AND STORAGE AREAS
SECTION 6313 – DETECTION AND ALARM SYSTEMS
SECTION 6314 – REFRIGERATION MACHINERY ROOM EQUIPMENT AND CONTROLS
SECTION 6315 – REFRIGERANT CONTROL VALVES <\/td>\n<\/tr>\n
131<\/td>\nSECTION 6316 – PROTECTION FROM MECHANICAL DAMAGE
SECTION 6317 – ELECTRICAL
SECTION 6318 – INSTRUCTIONS
SECTION 6319 – EMERGENCY SIGNS AND LABELS
SECTION 6320 – TESTING OF EQUIPMENT
SECTION 6321 – NOTIFICATION OF DISCHARGES
SECTION 6322 – STORAGE, HANDLING AND USE
SECTION 6323 – CHANGING OF REFRIGERANT TYPE
SECTION 6324 – RECORDS <\/td>\n<\/tr>\n
132<\/td>\nARTICLE 64 STATIONARY LEAD-ACID BATTERY SYSTEMS
SECTION 6401 – SCOPE
SECTION 6402 – DEFINITIONS
SECTION 6403 – PERMITS
SECTION 6404 – INSTALLATION AND MAINTNENANCE <\/td>\n<\/tr>\n
133<\/td>\nSPECIAL SUBJECTS ARTICLE 74 – COMPRESSED GASES
SECTION 7401 – GENERAL <\/td>\n<\/tr>\n
134<\/td>\nSECTION 7402 – STORAGE <\/td>\n<\/tr>\n
135<\/td>\nSECTION 7403 – USE AND HANDLING
SECTION 7404 – MEDICAL GAS SYSTEMS <\/td>\n<\/tr>\n
137<\/td>\nARTICLE 75 CRYOGENIC FLUIDS
SECTION 7501 – GENERAL <\/td>\n<\/tr>\n
138<\/td>\nTABLE 7501.9.2-A – MINIMUM SEPARATION DISTANCE BETWEEN STATIONARY CONTAINERS AND EXPOSURES <\/td>\n<\/tr>\n
139<\/td>\nTABLE 7501.9.3-A – MINIMUM SEPARATION DISTANCE BETWEEN PORTABLE CONTAINERS AND EXPOSURES
SECTION 7502 – STORAGE <\/td>\n<\/tr>\n
140<\/td>\nSECTION 7503 – USE AND HANDLING <\/td>\n<\/tr>\n
141<\/td>\nARTICLE 76 PREVENTION OF DUST EXPLOSIONS
SECTION 7601 – GENERAL
SECTION 7602 – ENCLOSURES
SECTION 7603 – SEPARATORS
SECTION 7604 – DUST COLLECTION
SECTION 7605 – HOUSEKEEPING
SECTION 7606 – ELECTRICAL GROUNDING
SECTION 7607 – SMOKING AND OPEN FLAMES
SECTION 7608 – EXPLOSION CONTROL <\/td>\n<\/tr>\n
142<\/td>\nARTICLE 77 EXPLOSIVE MATERIALS
SECTION 7701 – GENERAL <\/td>\n<\/tr>\n
143<\/td>\nSECTION 7702 – STORAGE <\/td>\n<\/tr>\n
144<\/td>\nTABLE 7702.3-A – TYPES OF MAGAZINES REQUIRED FOR STORAGE OF EXPLOSIVE MATERIAL <\/td>\n<\/tr>\n
147<\/td>\nSECTION 7703 – USE, HANDLING AND TRANSPORTATION <\/td>\n<\/tr>\n
149<\/td>\nSECTION 7704 – MANUFACTURING, ASSEMBLING AND TESTING <\/td>\n<\/tr>\n
150<\/td>\nTABLE 7704.5-A – MINIMUM INTRAPLANT SEPARATION BETWEEN OPERATING BUILDINGS CONTAINING MASS-DETONATING EXPLOSIVES OR FIREWORKS MANUFACTURING <\/td>\n<\/tr>\n
152<\/td>\nARTICLE 78 FIREWORKS AND PYROTECHNIC SPECIAL EFFECTS MATERIAL
SECTION 7801 – GENERAL
SECTION 7802 – FIREWORKS
TABLE 7802.3-A – MINIMUM MORTAR SEPARATION DISTANCES <\/td>\n<\/tr>\n
154<\/td>\nSECTION 7803 – PYROTECHNIC SPECIAL EFFECTS MATERIAL <\/td>\n<\/tr>\n
156<\/td>\nARTICLE 79 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 7901 – GENERAL <\/td>\n<\/tr>\n
159<\/td>\nTABLE 7901.1-A – CLASSIFICATION OF FLAMMABLE AND COMBUSTIBLE LIQUIDS
TABLE 7901.4-A – CLASS I ELECTRICAL EQUIPMENT LOCATIONS1 <\/td>\n<\/tr>\n
161<\/td>\nSECTION 7902 – STORAGE <\/td>\n<\/tr>\n
174<\/td>\nTABLE 7902.1-A – MAXIMUM SIZE OF CONTAINERS AND PORTABLE TANKS
TABLE 7902.1-B – VENT LINE DIAMETERS
TABLE 7902.2-A – STABLE LIQUIDS WITH OPERATING PRESSURE OF 2.5 PSIG (17.2 kPa) OR LESS <\/td>\n<\/tr>\n
175<\/td>\nTABLE 7902.2-B – STABLE LIQUIDS WITH OPERATING PRESSURE GREATER THAN 2.5 PSIG (17.2 kPa)
TABLE 7902.2-C – BOILOVER LIQUIDS
TABLE 7902.2-D – UNSTABLE LIQUIDS
TABLE 7902.2-E – CLASS III-B LIQUIDS <\/td>\n<\/tr>\n
176<\/td>\nTABLE 7902.2-F – REFERENCE TABLE FOR USE IN TABLES 7902.2-A, 7902.2-B AND 7902.2-D
TABLE 7902.2-G – MINIMUM SEPARATION (SHELL-TO-SHELL) OF TANKS CONTAINING STABLE LIQUIDS1,2
TABLE 7902.2-H – WETTED AREA VERSUS VENT CAPACITY1
TABLE 7902.2-I – WETTED AREA OVER 2,800 SQ. FT. (260.1 m2) AND PRESSURES OVER 1 PSIG (6.89 kPa) <\/td>\n<\/tr>\n
177<\/td>\nTABLE 7902.3-A – OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
TABLE 7902.5-A – EXEMPT AMOUNTS OF FLAMMABLE AND COMBUSTIBLE LIQUIDS – MAXIMUM QUANTITIES STORED PER CONTROL AREA
TABLE 7902.5-B – EXEMPT AMOUNTS OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAI MAXIMUM QUANTITIES STORED PER CONTROL AREAL SALES USES\u0141 <\/td>\n<\/tr>\n
178<\/td>\nTABLE 7902.5-C – MAXIMUM STORAGE HEIGHT IN CONTROL AREA
TABLE 7902.5-D – STORAGE ARRANGEMENTS FOR PALLETIZED SOLILD-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 7902.5-E – STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES <\/td>\n<\/tr>\n
179<\/td>\nTABLE 7902.5-F – AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN CONTAINERS AND PORTABLE TANKS
TABLE 7902.5-G – AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID PILE AND PALLETIZED STOOF LIQUIDS IN METAL CONTAINERS OF 5-GALLON (18.9 L) CAPACITY OR LESSRAGE <\/td>\n<\/tr>\n
180<\/td>\nTABLE 7902.5-H – AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAG5-GALLON (18.9 L) CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSE OF LIQUIDS IN CONTAINERS OF <\/td>\n<\/tr>\n
181<\/td>\nTABLE 7902.5-I – AUTOMATIC SPRINKLER PROTECTION FOR RACK STORAGE OF LIQUIDS IN CONTAINERS GREATER THAN 5-GALLON (18.9 L) CAPACITY
TABLE 7902.5-J – AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN CONTAINERS <\/td>\n<\/tr>\n
182<\/td>\nTABLE 7902.5-K – AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID OF 1 GALLON (3.79 L) CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6 1\/2 FEET (1981 MM) AND PALLETIZED STORAGE ABOVE IN A BOUBLE ROW RACK ARRAY STORAGE IN METAL CONTAINERS <\/td>\n<\/tr>\n
186<\/td>\nSECTION 7903 – DISPENSING, USE, MIXING AND HANDLING
TABLE 7903.2-A – SEPARATION OF PROCESSING VESSELS FROM PROPERTY LINES
TABLE 7903.2-B – EXEMPT AMOUNTS FOR USE, DISPENSING AND MIXING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS – MAXIMUM QUANTITIES PER CONTROL AREA
TABLE 7903.3-A – EXEMPT AMOUNTS FOR DISPENSING OF FLAMMABLE COMBUSTIBLE LIQUIDS -MAXIMUM QUANTITIES ALLOWED IN OUTDOOR AREA PER SINGLE PROPERTY UNDER SAME OWNERSHIP OR CONTROL <\/td>\n<\/tr>\n
187<\/td>\nSECTION 7904 – SPECIAL OPERATIONS <\/td>\n<\/tr>\n
193<\/td>\nTABLE 7904.2-A – MINIMUM VENT SIZES FOR TANKS <\/td>\n<\/tr>\n
194<\/td>\nARTICLE 80 HAZARDOUS MATERIALS
SECTION 8001 – GENERAL <\/td>\n<\/tr>\n
199<\/td>\nTABLE 8001.14-A – MULTIPLIER FOR EXEMPT AMOUNTS IN RETAIL OR WHOLESALE SALES IN OCCUPANCIES <\/td>\n<\/tr>\n
202<\/td>\nSECTION 8002 – CLASSIFICATION BY HAZARD <\/td>\n<\/tr>\n
203<\/td>\nTABLE 8001.15-A – EXEMPT AMOUNTS OF HAZARDOUS MATERIALS PRESENTING A PHYSICAL HAZARD MAXIMUM QUANTITIES PER CONTROL AREA <\/td>\n<\/tr>\n
204<\/td>\nTABLE 8001.15-B – EXEMPT AMOUNTS OF HAZARDOUS MATERIALS PRESENTING A HEALTH HAZARD MAXIMUM QUANTITIES PER CONTROL AREA <\/td>\n<\/tr>\n
205<\/td>\nTABLE 8001.15-C – EXEMPT AMOUNTS OF HAZARDOUS MATERIALS PRESENTING A PHYSICAL HAZARD – MAXIMUM QUANTITIES ALLOWED IN AN OUTDOOR CONTROL AREA
TABLE 8001.15-D – MATERIALS PRESENTING A HEALTH HAZARD\u0141 MAXIMUM QUANTITIES ALLOWED IN AN OUTDOOR CONTROL AREA <\/td>\n<\/tr>\n
206<\/td>\nSECTION 8003 – STORAGE <\/td>\n<\/tr>\n
208<\/td>\nTABLE 8003.1-A – REQUIRED SECONDARY CONTAINMENT\u0141HAZARDOUS MATERIALS SOLIDS AND LIQUIDS STORAGE <\/td>\n<\/tr>\n
209<\/td>\nTABLE 8003.1-B – REQUIRED DETACHED STORAGE (See Section 8003.1.15) <\/td>\n<\/tr>\n
210<\/td>\nTABLE 8003.3-A – RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS <\/td>\n<\/tr>\n
211<\/td>\nTABLE 8003.5-A – FLAMMABLE COMPRESSED GASES – DISTANCE FROM STORAGE TO EXPOSURES <\/td>\n<\/tr>\n
212<\/td>\nTABLE 8003.6-A – CLASS 1, 2 AND 3 OXIDIZER LIQUIDS AND SOLIDS – SEPARATION OF DEATACHED AND OUTDOOR STORAGE FROM OTHER BUILDINGS, PROPERTY LINES, STREETS, ALLEYS, PUBLIC WAYS OR MEANS OF EGRESS TO A PUBLIC WAY
TABLE 8003.6-B – CLASS 4 OXIDIZER LIQUIDS AND SOLIDS – SEPARATION OF DETACHED AND OUTDOOR STORAGE FROM OTHER BUILDINGS, PROPERTY LINES, STREETS, ALLEYS, PUBLIC WAYS OR MEANS OF EGRESS TO A PUBLIC WAY <\/td>\n<\/tr>\n
213<\/td>\nTABLE 8003.6-C – STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERS
TABLE 8003.6-D – STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS1,2,3
TABLE 8003.6-E – STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDS1, 2
TABLE 8003.6-F – STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
TABLE 8003.6-G – OXIDIZING GASES-DISTANCE FROM USE TO EXPOSURES1 <\/td>\n<\/tr>\n
214<\/td>\nTABLE 8003.7-A – SEPARATION OF DETACHED AND OUTDOOR STORAGE FROM OTHER BUILDINGS, PROPERTY LINES, STREETS, ALLEYS, PUBLIC WAYS OR MEANS OF EGRESS TO A PUBLIC WAY <\/td>\n<\/tr>\n
215<\/td>\nTABLE 8003.7-B – SEPARATION BETWEEN INDIVIDUAL DETACHED STORAGE BUILDINGS OR AREAS
TABLE 8003.7-C – STORAGE OF CLASS I ORGANIC PEROXIDES
TABLE 8003.7-D – STORAGE OF CLASS II AND III ORGANIC PEROXIDES
TABLE 8003.7-E – STORAGE OF CLASS IV ORGANIC PEROXIDES
TABLE 8003.8-A – PYROPHORIC GASES\u0141DISTANCE FROM STORAGE TO EXPOSURES <\/td>\n<\/tr>\n
219<\/td>\nSECTION 8004 – USE, DISPENSING AND HANDLING <\/td>\n<\/tr>\n
222<\/td>\nTABLE 8004.2-A – REQUIRED SECONDARY CONTAINMENT\u0141HAZARDOUS MATERIALS SOLIDS AND LIQUIDS USE <\/td>\n<\/tr>\n
223<\/td>\nARTICLE 81 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 8101 – GENERAL <\/td>\n<\/tr>\n
226<\/td>\nFIGURE 8101.4-A – MIXED COMMODITIES1,2
SECTION 8102 – GENERAL FIRE-PROTECTION AND <\/td>\n<\/tr>\n
227<\/td>\nSECTION 8103 – SOLID-PILED AND SHELF STORAGE <\/td>\n<\/tr>\n
228<\/td>\nSECTION 8104 – RACK STORAGE
SECTION 8105 – AUTOMATED STORAGE
SECTION 8106 – SPECIALTY STORAGE <\/td>\n<\/tr>\n
229<\/td>\nTABLE 81-A – GENERAL FIRE-PROTECTION AND LIFE-SAFETY REQUIREMENTS
TABLE 81-B – REQUIREMENTS FOR CURTAIN BOARDS AND SMOKE VENTING1 <\/td>\n<\/tr>\n
230<\/td>\nTABLE 8104.3-A – REQUIRED FLUE SPACES FOR RACK STORAGE1 <\/td>\n<\/tr>\n
231<\/td>\nARTICLE 82 LIQUEFIED PETROLEUM GASES
SECTION 8201 – SCOPE
SECTION 8202 – PERMITS, PLANS AND RECORDS
SECTION 8203 – INSTALLATION OF EQUIPMENT
SECTION 8204 – LOCATION OF CONTAINERS <\/td>\n<\/tr>\n
232<\/td>\nSECTION 8205 – PROHIBITED USE OF LP-GAS
SECTION 8206 – DISPENSING AND OVERFILLING
SECTION 8207 – SAFETY DEVICES
SECTION 8208 – SMOKING AND OTHER SOURCES OF IGNITION
SECTION 8209 – CLEARANCE TO COMBUSTIBLES
SECTION 8210 – PROTECTING CONTAINERS FROM VEHICLES
SECTION 8211 – FIRE PROTECTION
SECTION 8212 – STORAGE OF PORTABLE CONTAINERS AWAITING USE OR RESALE <\/td>\n<\/tr>\n
233<\/td>\nSECTION 8213 – CONTAINERS NOT IN SERVICE
SECTION 8214 – PARKING AND GARAGING <\/td>\n<\/tr>\n
234<\/td>\nTABLE 8204-A – LOCATION OF CONTAINERS
TABLE 8212-A – LOCATION OF CONTAINERS AWAITING USE OR RESALE STORED OUTSIDE OF BUILDINGS <\/td>\n<\/tr>\n
235<\/td>\nARTICLE 83 (NOT USED) <\/td>\n<\/tr>\n
236<\/td>\nARTICLE 84 MOTION PICTURE PROJECTION
SECTION 8401 SCOPE
SECTION 8402 PROJECTION ROOOMS
SECTION 8403 SMOKING
SECTION 8404 PROJECTION EQUIPMENT
SECTION 8405 FILM STORAGE AND USE <\/td>\n<\/tr>\n
237<\/td>\nARTICLE 85 ELECTRICAL EQUIPMENT AND WIRING
SECTION 8501 SCOPE
SECTION 8502 DEFINITIONS
SECTION 8503 USE OF TEMPORARY WIRING
SECTION 8504 ABATEMENT OF ELECTRICAL HAZARDS
SECTION 8505 ELECTRICAL MOTORS
SECTION 8506 EXTENSION CORDS AND FLEXIBLE CORDS
SECTION 8507 MULTIPLUG ADAPTERS
SECTION 8508 POWER TAPS
SECTION 8509 ACCESS TO SWITCHBOARDS AND PANELBOARDS <\/td>\n<\/tr>\n
238<\/td>\nARTICLE 86 (NOT USED) <\/td>\n<\/tr>\n
239<\/td>\nARTICLE 87 FIRE SAFETY DURING CONSTRUCTION, ALTERATION OR DEMOLITION OF A BUILDING
SECTION 8701 SCOPE
SECTION 8702 PERMITS
SECTION 8703 APPROVALS
SECTION 8704 FIRESAFETY DURING CONSTRUCTION <\/td>\n<\/tr>\n
240<\/td>\nSECTION 8705 ALTERATIONS OF BUILDINGS
SECTION 8706 FIRESAFETY DURING DEMOLITION
SECTION 8707 ASBESTOS REMOVAL <\/td>\n<\/tr>\n
241<\/td>\nARTICLE 88 AEROSOL PRODUCTS
SECTION 8801 GENERAL
SECTION 8802 STORAGE AND RETAIL DISPLAYS <\/td>\n<\/tr>\n
243<\/td>\nTABLE 8802.2-A RETAIL DISPLAY OF LEVELS 2 AND 3 AEROSOL PRODUCTS IN RETAIL SALES OCCUPANCIES, MAXIMUM QUANTITIES
TABLE 8802.2-B STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL SALES OCCUPANCIES, MAXIMUM QUANTITIES
TABLE 8802.3-B SEGREGATED LEVELS 2 AND 3 AEROSOL PRODUCT STORAGE-GENERAL PURPOSE WAREHOUSES AND STORAGE ROOMS MAXIMUM STORAGE AREA, SPRINKLER SYSTEM AND STORAGE ARRANGEMENT <\/td>\n<\/tr>\n
244<\/td>\nTABLE 8802.3-C SEGREGATED LEVELS 2 AND 3 AEROSOL PRODCUT STORAGE-GENERAL PURPOSE WAREHOUSES AND STORAGE ROOMS AISLE WIDTHS AND DISTANCE TO AISLES
TABLE 8802.3-D SEGREGATED LEVELS 2 AND 3 AEROSOL PRODUCT STORAGE-GENERAL PURPOSE WAREHOUSES AND STORAGE ROOMS SEPARATION FROM FLAMMABLE AND COMBUSTIBLE LIQUIDS
TABLE 8802.5-A EXTERIOR STORAGE OF LEVELS 2 AND 3 AEROSOL PRODUCTS-DISTANCE TO EXPOSURES <\/td>\n<\/tr>\n
245<\/td>\nSECTION 8803 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS AND STORAGE ARRANGEMENTS
TABLE 8803.1-A LEVEL 2 AEROSOL PRODUCTS ARRANGEMENT AND PROTECTION OF PALLETIZED, SOLID-PILE AND SHELF STORAGE <\/td>\n<\/tr>\n
246<\/td>\nTABLE 8803.1-B LEVEL 3 AEROSOL PRODUCTS-ARRANGEMENT AND PROTECTION OF PALLETIZED AND SOLID PILE STORAGE
TABLE 8803.1-C LEVEL 2 AEROSOL PRODUCTS -ARRANGEMENT AND PROTECTION OF RACK STORAGE WITH ESFR SPRINKLERS
TABLE 8803.1-D LEVEL 3 AEROSOL PRODUCTS-ARRANGEMENT AND PROTECTION OF RACK STORAGE WITH ESFR SPRINKLERS <\/td>\n<\/tr>\n
247<\/td>\nTABLE 8803.1-E LEVEL 2 AEROSOL PRODUCTS-ARRANGEMENT AND PROTECTION OF RACK STORAGE WITH SPRAY SPRINKLERS
TABLE 8803.1-F LEVEL 2 AEROSOL PRODUCTS IN RACKS WITH SOLID SHELVES AND LEVEL 3 AEROSOL PRODUCTS ARRANGEMENT AND PROTECTION OF RACK STORAGE WITH SPRAY SPRINKLERS <\/td>\n<\/tr>\n
248<\/td>\nARTICLE 90 STANDARDS
SECTION 9001 GENERAL
SECTION 9002 UFC STANDARDS
SECTION 9003 RECOGNIZED STANDARDS <\/td>\n<\/tr>\n
251<\/td>\nAPPENDIX I-A LIFE-SAFETY REQUIREMENTS FOR EXISTING BUILDINGS OTHER THAN HIGH RISE
SECTION 1 GENERAL
SECTION 2 MEANS OF EGRESS <\/td>\n<\/tr>\n
252<\/td>\nSECTION 3 ENCLOSURE OF VERTICAL SHAFTS
SECTION 4 BASEMENT ACCESS OR SPRINKLER PROTECTION
SECTION 5 STANDPIPES
SECTION 6 SMOKE DETECTORS
SECTION 7 SEPARATION OF OCCUPANCIES <\/td>\n<\/tr>\n
253<\/td>\nAPPENDIX I-B LIFE-SAFETY REQUIREMENTS FOR EXISTING HIGH-RISE BUILDINGS
SECTION 1 SCOPE
SECTION 2 GENERAL
SECTION 3 COMPLIANCE DATA
SECTION 4 AUTHORITY OF THE CHIEF
SECTION 5 APPEALS BOARD
SECTION 6 SPECIFIC PROVISIONS AND ALTERNATES <\/td>\n<\/tr>\n
256<\/td>\nTABLE A-I-B-1 OCCUPANCY CLASSIFICATION AND USE <\/td>\n<\/tr>\n
257<\/td>\nAPPEXDIX I-C STAIRWAY IDENTIFICATION
SECTION 1 SCOPE
SECTION 2 GENERAL
SECTION 3 SIGN DETAILS
SECTION 4 EXAMPLES <\/td>\n<\/tr>\n
258<\/td>\nAPPENDIX II-A SUPPRESSION AND CONTROL OF HAZARDOUS FIRE AREAS
SECTION 1 SCOPE
SECTION 2 DEFINITIONS
SECTION 3 PERMITS
SECTION 4 RESTRICTED ENTRY
SECTION 5 TRESPASSING ON POSTED PROPERTY
SECTION 6 SMOKING
SECTION 7 SPARK ARRESTERS
SECTION 8 TRACER BULLETS, TRACER CHARGES, ROCKETS AND MODEL AIRCRAFT
SECTION 9 EXPLOSIVES AND BLASTING
SECTION 10 FIREWORKS
SECTION 11 APIARIES
SECTION 12 OPEN-FLAME DEVICES <\/td>\n<\/tr>\n
259<\/td>\nSECTION 13 OUTDOOR FIRES
SECTION 14 INCINERATORS AND FIREPLACES
SECTION 15 CLEARANCE OF BRUSH AND VEGETATIVE GROWTH FROM ELECTRICAL TRANSMISSION LINES
SECTION 16 CLEARANCE OF BRUSH OR VEGETATIVE GROWTH FROM STRUCTURES <\/td>\n<\/tr>\n
260<\/td>\nSECTION 17 CLEARANCE OF BRUSH OR VEGETATIVE GROWTH FROM ROADWAYS
SECTION 18 UNUSUAL CIRCUMSTANCES
SECTION 19 DUMPING
SECTION 20 DISPOSAL OF ASHES
SECTION 21 USE OF FIRE ROADS AND FIREBREAKS
SECTION 22 USE OF MOTOCYCLES, MOTOR SCOOTERS AND MOTOR VEHICLES
SECTION 23 TAMPERING WITH FIRE DEPARTMENT LOCKS, BARRICADES AND SIGNS
SECTION 24 LIABILITY FOR DAMAGE <\/td>\n<\/tr>\n
261<\/td>\nAPPENDIX II-B PROTECTION OF FLAMMABLE AND COMBUSTIBLE LIQUID TANKS IN LOCATIONS SUBJECT TO FLOODING
SECTION 1 PIPE CONNECTIONS
SECTION 2 ABOVEGROUND TANKS
SECTION 3 UNDERGROUND TANKS
SECTION 4 INDEPENDENT WATER SUPPLY FACILITIES
SECTION 5 STRUCTURAL GUIDES <\/td>\n<\/tr>\n
262<\/td>\nSECTION 6 SAFE PRACTICES
SECTION 7 INSPECTIONS <\/td>\n<\/tr>\n
263<\/td>\nAPPENDIX II-C MARINAS
SECTION 1 SCOPE
SECTION 2 PLANS AND APPROVALS
SECTION 3 PERMITS
SECTION 4 DEFINITIONS
SECTION 5 FIRE PREVENTION
SECTION 6 FIRE-PROTECTION EQUIPMENT
SECTION 7 TRANSMISSION OF ALARMS
SECTION 8 MARINE MOTOR VEHICLE FUEL-DISPENSING STATIONS <\/td>\n<\/tr>\n
264<\/td>\nAPPENDIX II-D RIFLE RANGES
SECTION 1 PERMIT
SECTION 2 SUPERVISION BY RANGE OFFICER
SECTION 3 QUALIFICATIONS OF RANGE OFFICER
SECTION 4 INSPECTION AND DISPOSAL OF AMMUNITION
SECTION 5 PORTABLE FIRE APPLIANCES
SECTION 6 REMOVAL OF VEGETATION
SECTION 7 WARNINGS <\/td>\n<\/tr>\n
265<\/td>\nAPPENDIX II-E HAZARDOUS MATERIALS MANAGEMENT PLANS AND HAZARDOUS MATERIALS INVENTORY STATEMENTS
SECTION 1 SCOPE
SECTION 2 HAZARDOUS MATERIALS INVENTORY STATEMENTS (HMIS)
SECTION 3 HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) <\/td>\n<\/tr>\n
266<\/td>\nSECTION 4 MAINTENANCE OF RECORDS <\/td>\n<\/tr>\n
267<\/td>\nFIGURE A-II-E-1 SAMPLE FORMAT HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) INSTRUCTIONS
SECTION I FACILITY DESCRIPTION
SECTION II HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) <\/td>\n<\/tr>\n
268<\/td>\nSECTION III SEPARATION AND MONITORING
SECTION IV WASTE DISPOSAL
SECTION V RECORD KEEPING
SECTION VI EMERGENCY-RESPONSE PLAN
SECTION VII EMERGENCY-RESPONSE TRAINING PLAN <\/td>\n<\/tr>\n
269<\/td>\nHAZARDOUS MATERIALS MANAGEMENT PLAN
SECTION I: FACILITY DESCRIPTION
PART A GENERAL INFORMATION
PART B GENERAL FACILITY DESCRIPTION\/SITE PLAN
PART C FACILITY MAP
SECTION II: HAZARDOUS MATERIAL INVENTORY STATEMENT
PART A DECLARATION
PART B HAZARDOUS MATERIALS INVENTORY STATEMENT <\/td>\n<\/tr>\n
270<\/td>\nSECTION III: SEPARATION, SECONDARY CONTAINMENT AND MONITORING
PART A ABOVEGROUND STORAGE AREAS
PART B UNDERGROUND <\/td>\n<\/tr>\n
271<\/td>\nSECTION IV: WASTE DISPOSAL
SECTION V: RECORD KEEPING
SECTION VI: EMERGENCY-RESPONSE PLAN <\/td>\n<\/tr>\n
272<\/td>\nSECTION VII: EMERGENCY -RESPONSE TRAINING PLAN <\/td>\n<\/tr>\n
273<\/td>\nAPPENDIX II-F PROTECTED ABOVEGROUND TANKS FOR MOTOR VEHICLE FUEL-DISPENSING STATIONS OUTSIDE BUILDINGS
SECTION 1 SCOPE
SECTION 2 DEFINITIONS
SECTION 3 PERMITS AND PLANS
SECTION 4 TANK DESIGN
SECTION 5 INSTALLATION OF TANKS <\/td>\n<\/tr>\n
274<\/td>\nSECTION 6 INSTALLATION OF DISPENSING AND PIPING SYSTEMS
SECTION 7 PARKING OF TANK VEHICLES
SECTION 8 MAINTENANCE
TABLE A-II-F-1- MINIMUM SEPARATION REQUIREMENTS FOR PROTECTED ABOVEGROUND TANKS <\/td>\n<\/tr>\n
275<\/td>\nAPPENDIX II-G SECONDARY CONTAINMENT FOR UNDERGROUND TANK SYSTEMS CONTAINING FLAMMABLE OR COMBUSTIBLE LIQUIDS
SECTION 1 SCOPE
SECTION 2 CIRCUMSTANCES WARRANTING SECONDARY CONTAINMENT
SECTION 3 APPROVED METHODS OF SECONDARY CONTAINMENT <\/td>\n<\/tr>\n
276<\/td>\nAPPENDIX II-H SITE ASSESSMENTS FOR DETERMINING POTENTIAL FIRE AND EXPLOSION RISKS FROM UNDERGROUND FLAMMABLE OR COMBUSTIBLE LIQUID TANK LEAKS
SECTION 1 SCOPE
SECTION 2 SITE ASSESSMENT CRITERIA
SECTION 3 SITE ASSESSMENT RECORDS <\/td>\n<\/tr>\n
277<\/td>\nAPPENDIX II-I OZONE GAS-GENERATING EQUIPMENT
SECTION 1 SCOPE
SECTION 2 DEFINITIONS
SECTION 3 STANDARDS
SECTION 4 LOCATION
SECTION 5 PIPING VALVES AND FITTINGS
SECTION 6 AUTOMATIC SHUTDOWN
SECTION 7 MANUAL SHUTDOWN <\/td>\n<\/tr>\n
278<\/td>\nAPPENDIX II-J STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN TANKS LOCATED WTHIN BELOW-GRADE VAULTS
SECTION 1 SCOPE
SECTION 2 DEFINITIONS
SECTION 3 GENERAL
SECTION 4 LOCATION
SECTION 5 VAULT CONSTRUCTION
SECTION 6 VENTILATION
SECTION 7 TANKS AND PIPING <\/td>\n<\/tr>\n
279<\/td>\nSECTION 8 MONITORING AND DETECTION
SECTION 9 DISPENSING SYSTEMS
SECTION 10 FIRE SUPPRESSION AND WATER-SUPPLY SYSTEM
SECTION 11 SIGNS <\/td>\n<\/tr>\n
280<\/td>\nAPPENDIX III-A FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION 1 SCOPE
SECTION 2 DEFINITIONS
SECTION 3 MODIFICATIONS
SECTION 4 FIRE AREA
SECTION 5 FIRE-FLOW REQUIREMENTS FOR BUILDINGS <\/td>\n<\/tr>\n
281<\/td>\nTABLE A-III-A-1 MINIMUM REQUIRED FIRE FLOW AND FLOW DURATION FOR BUILDINGS <\/td>\n<\/tr>\n
282<\/td>\nAPPENDIX III-B FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION 1 SCOPE
SECTION 2 LOCATION
SECTION 3 NUMBER OF FIRE HYDRANTS
SECTION 4 CONSIDERATION OF EXISTING FIRE HYDRANTS
SECTION 5 DISTRIBUTION OF FIRE HYDRANTS
TABLE A-III-B-1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS <\/td>\n<\/tr>\n
283<\/td>\nAPPENDIX III-C INSPECTION TESTING AND MAINTENANCE OF WATER-BASED FIRE-PROTECTION SYSTEMS
SECTION 1 GENERAL <\/td>\n<\/tr>\n
284<\/td>\nAPPENDIX III-D BASEMENT PIPE INLETS
SECTION 1 SCOPE
SECTION 2 LOCATION
SECTION 3 SPECIFICATIONS <\/td>\n<\/tr>\n
285<\/td>\nAPPENDIX IV-A INTERIOR FLOOR FINISH
SECTION 1 SCOPE
SECTION 2 GENERAL
SECTION 3 TESTING AND CLASSIFICATION OF MATERIALS
TABLE A-IV-A-1 INTERIOR FLOOR FINISH REQUIREMENTS <\/td>\n<\/tr>\n
286<\/td>\nAPPENDIX IV-B CHRISTMAS TREES
SECTION 1 SCOPE
SECTION 2 PERMITS
SECTION 3 FLAME RETARDANCE
SECTION 4 TAGS
SECTION 5 SUPPORT DEVICE
SECTION 6 BUTT CUT
SECTION 7 WATERING
SECTION 8 DRYNESS
SECTION 9 OPEN FLAMES
SECTION 10 ELECTRIC LIGHTS
SECTION 11 DAILY TESTS
TABLE A-IV-B-1 SUPPORT STAND WATER CAPACITY <\/td>\n<\/tr>\n
287<\/td>\nAPPENDIX V-A NATIONALLY RECOGNIZED STANDARDS OF GOOD PRACTICE
SECTION 1 SCOPE
SECTION 2 STANDARDS <\/td>\n<\/tr>\n
288<\/td>\nAPPENDIX VI-A HAZARDOUS MATERIALS CLASSIFICATIONS
SECTION 1 SCOPE
SECTION 2 HAZARD CATEGORIES <\/td>\n<\/tr>\n
291<\/td>\nTABLE A-VI-2.2 RADIATION EMITTED FROM ISOTOPES
SECTION 3 EVALUATION OF HAZARDS <\/td>\n<\/tr>\n
292<\/td>\nTABLE A-VI-A-1 NORMALIZATION FACTOR <\/td>\n<\/tr>\n
293<\/td>\nSECTION 4 REFERENCE PUBLICATIONS <\/td>\n<\/tr>\n
295<\/td>\nAPPENDIX VI-B HAZARD RANKING
SECTION 1 SCOPE
SECTION 2 GENERAL
SECTION 3 DEGREE OF HAZARD <\/td>\n<\/tr>\n
296<\/td>\nAPPENDIX VI-C EMERGENCY RELIEF VENTING FOR FIRE EXPOSURE FOR ABOVEGROUND TANKS
TABLE A-VI-C-1 EQUATIONS USED TO COMPILE FIGURE A-VI-C-1 <\/td>\n<\/tr>\n
297<\/td>\nFIGURE A-VI-C-1 COMPOSITE CURVE BASED ON EQUATIONS FOUND IN TABLE A-VI-C-1
TABLE A-VI-C-2 CONSTANTS TO CALCULATE VAPOR GENERATED AND EQUIVALENT FREE AIR FOR LIQUIDS OTHER THAN HEXANE <\/td>\n<\/tr>\n
298<\/td>\nTABLE A-VI-C-3 APPROXIMATE WETTED AREAS FOR HORIZONTAL TANKS WITH FLAT HEADS <\/td>\n<\/tr>\n
299<\/td>\nCONTINUED -TABLE A-V1-C-3 APPROXIMATE WETTED AREAS FOR HORIZONTAL <\/td>\n<\/tr>\n
300<\/td>\nAPPENDIX VI-D MODEL CITATION PROGRAM
SECTION 1 GENERAL
SECTION 2 OPERATING PROCEDURE CITATION PROGRAM <\/td>\n<\/tr>\n
302<\/td>\nFIGURE A-VI-D-1 MODEL CITATION INITIATION CORRESPONDENCE
FIGURE A-VI-D-2 MODEL CITATION ORDINANCE <\/td>\n<\/tr>\n
303<\/td>\nFIGURE A-VI-D-3 PRE-CITATION LETTER <\/td>\n<\/tr>\n
304<\/td>\nFIGURE A-VI-D-4 FORMS APPROVED BY JUDICIAL COUNCIL <\/td>\n<\/tr>\n
307<\/td>\nFIGURE A-VI-D-5 INSERT LOCAL ORDINANCES WHERE APPLICABLE <\/td>\n<\/tr>\n
308<\/td>\nAPPENDIX VI-E REFERENCE TABLES FROM THE UNIFORM BUILDING CODE
TABLE 3-A DESCRIPTION OF OCCUPANCIES BY GROUP AND DIVISION <\/td>\n<\/tr>\n
309<\/td>\nTABLE 3-B REQUIRED SEPARATION IN BUILDINGS OF MIXED OCCUPANCY (HOURS)
TABLE 3-C REQUIRED SEPARATION OF SPECIFIC-USE AREAS IN GROUP I, DIVISIONS 1.1 HOSPITALS AND NURSING HOMES <\/td>\n<\/tr>\n
310<\/td>\nTABLE 3-F MINIMUM DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS <\/td>\n<\/tr>\n
311<\/td>\nTABLE 5-A EXTERIOR WALL AND OPENING PROTECTION BASED ON LOCATION ON PROPERTY FOR ALL CONSTRUCTION TYPES <\/td>\n<\/tr>\n
315<\/td>\nTABLE 5-B BASIC ALLOWABLE BUILDING HEIGHTS AND BASIC ALLOWABLE FLOOR AREA FOR BUILDING ONE STORY IN HEIGHT <\/td>\n<\/tr>\n
316<\/td>\nTABLE 6-A TYPES OF CONSTRUTION-FIRE-RESISTIVE REQUIREMENTS (IN HOURS) <\/td>\n<\/tr>\n
317<\/td>\nTABLE 8-A FLAME-SPREAD CLASSIFICATION
TABLE 8-B MAXIMUM FLAME-SPREAD CLASS <\/td>\n<\/tr>\n
318<\/td>\nTABLE 10-A MINIMUM EGRESS REQUIREMENTS <\/td>\n<\/tr>\n
319<\/td>\nAPPENDIX VI-F RECOMMENDED SEPARATION DISTANCES FOR EXPLOSIVE MATERIALS
SECTION 1 CLASSIFICATION OF EXPLOSIVE MATERIALS
SECTION 2 RECOMMENDED SEPARATION DISTANCES FOR EXPLOSIVE MATERIALS
TABLE A-VI-F-1 TRANSITION DATES FOR EXPLOSIVES CLASSIFICATIONS AND RELATED DOT REGULATIONS <\/td>\n<\/tr>\n
320<\/td>\nTABLE A-VI-F-2 DEFINITIONS FOR DIVISIONS OF CLASS 1 (EXPLOSIVE) MATERIALS
TABLE A-VI-F-3 COMPARISON OF OLD TO CURRENT EXPLOSIVES CLASSIFICATIONS
TABLE A-VI-F-4 EXPLOSIVES COMPATIBILITY GROUPS <\/td>\n<\/tr>\n
321<\/td>\nTABLE A-VI-F-5 AMERICAN TABLE OF DISTANCES FOR STORAGE OF EXPLOSIVE MATERIALS <\/td>\n<\/tr>\n
323<\/td>\nTABLE A-VI-F-6 TABLE OF RECOMMENDED SEPARATION DISTANCES OF AMMONIUM NITRATE AND BLASTING AGENTS FROM EXPLOSIVES OR BLASTING AGENTS <\/td>\n<\/tr>\n
324<\/td>\nTABLE A-VI-F-7 TABLE OF DISTANCES FOR STORAGE OF LOW EXPLOSIVES <\/td>\n<\/tr>\n
325<\/td>\nTABLE A-VI-F-8 DISTANCES FOR THE OPEN BURNING OF EXPLOSIVES <\/td>\n<\/tr>\n
326<\/td>\nTABLE A-VI-F-9 DISTANCES FOR THE OPEN DETONATION OF EXPLOSIVES <\/td>\n<\/tr>\n
327<\/td>\nAPPENDIX VI-G CRYOGENIC FLUIDS WEIGHT AND VOLUME EQUIVALENTS
TABLE A-VI-G-1 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS <\/td>\n<\/tr>\n
328<\/td>\nAPPENDIX VI-H REFRIGERANT GROUPS AND PROPERTIES
TABLE A-VI-H-1 REFRIGERANT HAZARD CATEGORIES AND HAZARD SIGNALS <\/td>\n<\/tr>\n
330<\/td>\nAPPENDIX VI-I UNIT CONVERSION TABLES
UNIT CONVERSION TABLES SI SYMBOLS AND PREFIXES <\/td>\n<\/tr>\n
331<\/td>\nCONVERSION FACTORS <\/td>\n<\/tr>\n
333<\/td>\nGAGE CONVERSION TABLE <\/td>\n<\/tr>\n
334<\/td>\nINDEX
A
B <\/td>\n<\/tr>\n
335<\/td>\nC <\/td>\n<\/tr>\n
336<\/td>\nD
E <\/td>\n<\/tr>\n
337<\/td>\nF <\/td>\n<\/tr>\n
341<\/td>\nG
H <\/td>\n<\/tr>\n
342<\/td>\nI
J
K <\/td>\n<\/tr>\n
343<\/td>\nL
M
N <\/td>\n<\/tr>\n
344<\/td>\nO
P <\/td>\n<\/tr>\n
345<\/td>\nR
S <\/td>\n<\/tr>\n
347<\/td>\nT
U <\/td>\n<\/tr>\n
348<\/td>\nV
W <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Uniform Fire Code Volume I<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n1997<\/td>\n348<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":441012,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-441008","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/441008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/441012"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=441008"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=441008"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=441008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}