{"id":425612,"date":"2024-10-20T06:57:46","date_gmt":"2024-10-20T06:57:46","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-23-30433745-dc-2023\/"},"modified":"2024-10-26T13:08:03","modified_gmt":"2024-10-26T13:08:03","slug":"bsi-23-30433745-dc-2023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-23-30433745-dc-2023\/","title":{"rendered":"BSI 23\/30433745 DC 2023"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | 30433745-NC.pdf <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | ISO_DIS 13100 ed.1 – id.78452 Enquiry PDF (en).pdf <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 3.1 General terms <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3.2 Electrokinetic and electroacoustic phenomena <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 3.3 Terms describing porous materials <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 4 List of symbols <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5 Streaming current and streaming potential 5.1 General overview <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.2 Streaming potential in DC mode 5.2.1 General 5.2.2 Measurement of the streaming potential coupling coefficient <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2.3 Calculation of the zeta potential <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3 Streaming current in AC mode <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6 Measurement of DC streaming potential for porous materials 6.1 Operational procedures <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.2 Instrument location 6.3 Sample holder 6.4 Sample preparation <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.5 Test solution <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.6 Verification 6.7 Repeatability and reproducibility <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.8 Sources of measurement error 6.8.1 Contamination of the current sample by the previous sample 6.8.2 Inappropriate sample preparation procedure 6.8.3 Inappropriate test solution <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.8.4 Air bubbles 6.8.5 Faulty electrodes <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.8.6 Limitation of the Smoluchowski approximation 7 Measurement of AC streaming current for porous materials 7.1 Instrument setup for particle deposits <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 7.2 Instrument setup for consolidated porous materials <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 7.3 Sample requirements 7.4 Calibration and verification 7.4.1 Reference materials <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7.4.2 Calibration 7.4.3 Verification 7.5 Repeatability and intermediate precision 7.6 Sources of measurement error <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 8 Reporting of zeta potential results 8.1 General information 8.2 Specific information <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex\u20acA (informative) Electric double layer models in porous materials <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Annex\u20acB (informative) Debye length <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex\u20acC (informative) Porosity determination <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS ISO 13100. Methods for zeta potential determination. Streaming potential and streaming current methods for porous materials<\/b><\/p>\n |