{"id":403478,"date":"2024-10-20T05:06:16","date_gmt":"2024-10-20T05:06:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-60974-142018-2\/"},"modified":"2024-10-26T09:06:26","modified_gmt":"2024-10-26T09:06:26","slug":"bs-en-iec-60974-142018-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-60974-142018-2\/","title":{"rendered":"BS EN IEC 60974-14:2018"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Blank Page <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | CONTENTS <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 4 Safety precautions 5 Testing personnel 6 Verification accuracies \u2013 permitted deviations <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Table 1 \u2013 Calibration accuracies of displayed values Table 2 \u2013 Validation accuracies of set values <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 7 Arc welding power sources 7.1 Selection related to calibration, validation or consistency testing of process-relevant parameters 7.1.1 Verification method <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 7.1.2 Special features for AC determination of welding power source output mode for verification Figures Figure 1 \u2013 Determination of verification method <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Figure 2 \u2013 Determination of verification based on power source type <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 7.2 Testing equipment and test setup 7.2.1 Test setup 7.2.2 Reference instruments Figure 3 \u2013 Test setup example <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7.2.3 Test load 7.2.4 Conventional load test values Figure 4 \u2013 Example 10 kHz filter with reference voltmeter <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7.3 Calibration, validation and consistency testing procedure 7.3.1 General 7.3.2 Calibration of displayed value reading <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7.3.3 Validation of set values 7.3.4 Consistency test of set values 8 Wire feeder 8.1 General <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.2 Requirements for verification 8.3 Method 9 Frequency of verification <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 10 Marking and verification report 10.1 Marking 10.2 Verification report <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Annex A (informative)Diagrams of verification accuracies A.1 Calibration accuracies of displayed values A.2 Validation accuracies of set values Figure A.1 \u2013 Diagrams of calibration accuracies <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure A.2 \u2013 Diagrams of validation accuracies <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex B (informative)Measured value formation B.1 General B.2 Averaging of measurement values <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex C (informative)Slope, pulse and synergic controls C.1 Verification accuracy C.2 Requirements for verification <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | C.3 Method C.4 Pulsed MIG and synergic controls <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex D (informative)Precautions to be taken with TIG welding equipment <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Annex E (informative)Samples of verification reports E.1 Sample of calibration report <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | E.2 Sample of validation report <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | E.3 Sample of consistency test report <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Arc welding equipment – Calibration, validation and consistency testing<\/b><\/p>\n |