{"id":363242,"date":"2024-10-20T01:44:30","date_gmt":"2024-10-20T01:44:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-bpvc-iii-1-nb-2013\/"},"modified":"2024-10-26T02:44:12","modified_gmt":"2024-10-26T02:44:12","slug":"asme-bpvc-iii-1-nb-2013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-bpvc-iii-1-nb-2013\/","title":{"rendered":"ASME BPVC III 1 NB 2013"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
43<\/td>\n | NB-1132.2-1 Attachments in the Component Support Load Path That Do Not Perform a Pressure\u2011Retaining Function <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | NB-1132.2-2 Attachments That Do Not Perform a Pressure\u2011Retaining Function and Are Not in the Component Support Load Path (Nonstructural Attachments) <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | NB-1132.2-3 Attachments That Perform a Pressure\u2011Retaining Function <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | NB-1132.2-4 Attachments Within the Reactor Pressure Vessel (Core Support Structures) That Do Not Perform a Pressure\u2011Retaining Function <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | NB-2332(a)-1 Required Cv Values for Piping, Pumps, and Valves NB-2333-1 Required Cv Values for Bolting Material <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | NB-2432.1-1 Sampling of Welding Materials for Chemical Analysis <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | NB-2432.2(a)-1 Chemical Analysis for Reactor Vessel Welding Material NB-2432.2(a)-2 Chemical Analysis for Welding Material for Other Than Reactor Vessel Welds <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | NB-2433.1-1 Weld Metal Delta Ferrite Content <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | NB-2552-1 Axial Propagation of Sound in Tube Wall <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | NB-2571-1 Required Examinations <\/td>\n<\/tr>\n | ||||||
72<\/td>\n | NB-2575.2-1 Typical Pressure\u2011Retaining Parts of Pumps and Valves <\/td>\n<\/tr>\n | ||||||
85<\/td>\n | NB-3213-1 Examples of Reversing and Nonreversing Dynamic Loads <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | NB-3217-1 Classification of Stress Intensity in Vessels for Some Typical Cases <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | NB-3217-2 Classification of Stress Intensity in Piping, Typical Cases <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | NB-3221-1 Stress Categories and Limits of Stress Intensity for Design Conditions <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | NB-3222-1 Stress Categories and Limits of Stress Intensity for Level A and Level B Service Limits <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | NB-3224-1 Stress Categories and Limits of Stress Intensity for Level C Service Limits <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | NB-3228.5(b)-1 Values of m, n, and Tmax for Various Classes of Permitted Materials <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | NB-3332.2-1 Chart for Determining Value of F <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | NB-3338.2(a)-1 Direction of Stress Components <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | NB-3338.2(a)-2 Nozzle Dimensions <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | NB-3338.2(c)-1 Stress Indices for Nozzles <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | NB-3339.1(b)-1 Examples of Acceptable Transition Details NB-3339.3-1 Required Minimum Reinforcing Area Ar <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | NB-3339.4-1 Limits of Reinforcing Zone <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | NB-3339.7(c)-1 Stress Indices for Internal Pressure Loading <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | NB-3351-1 Welded Joint Locations Typical of Categories A, B, C, and D <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | NB-3352-1 Typical Butt Joints <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | NB-3361-1 Category A and B Joints Between Sections of Unequal Thickness <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | NB-3423-1 Typical Single Volute Casing <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | NB-3423-2 Typical Double Volute Casing NB-3433.4-1 Minimum Tangential Inlet and Outlet Wall Thickness <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | NB-3441.1-1 Type A Pump NB-3441.1-2 Type A Pump NB-3441.2-1 Type B Pump <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | NB-3441.3-1 Type C Pump NB-3441.3-2 Type C Pump <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | NB-3441.4(a)-1 Type D Pump NB-3441.5-1 Type E Pump NB-3441.6(a)-1 Type F Pump <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | NB-3544.1(a)-1 Fillets and Corners NB-3544.1(c)-1 Ring Grooves <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | NB-3544.3-1 Lugs and Protuberances <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | NB-3544.7-1 Flat Wall Limitation <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | NB-3545.1(a)-1 Pressure Area Method <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | NB-3545.2(a)-1 Critical Sections of Valve Bodies <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | NB-3545.2(c)-1 Model for Determining Secondary Stress in Valve Crotch Region <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | NB-3545.2(c)-3 Thermal Stress Index Versus Thickness Continuity Run or Branch <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | NB-3545.2(c)-4 Secondary Stress Index Versus Thickness Discontinuity Run or Branch <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | NB-3545.2(c)-5 C4 Versus Te1\/te NB-3545.2(c)-6 Stress Index for Thermal Fatigue <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | NB-3591.1-1 Typical Pressure Relief Devices <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | NB-3591.1-2 Typical Pressure Relief and Safety Relief Devices <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | NB-3594.3-1 Valve Nozzle <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | NB-3622-1 Examples of Reversing and Nonreversing Dynamic Loads <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | NB-3641.1(a)-1 Values of A <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | NB-3642.1(b)-1 Bend Radius Versus Thickness <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | NB-3643.3(a)-1 Branch Connection Nomenclature <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | NB-3643.3(a)-2 Typical Reinforcement of Openings <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | NB-3643.3(a)-3 Typical Reinforced Extruded Outlet <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | NB-3644(b)-1 Miter Joint Geometry <\/td>\n<\/tr>\n | ||||||
154<\/td>\n | NB-3647.2-1 Types of Permanent Blanks <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | NB-3653.2(b)-1 Decomposition of Temperature Distribution Range <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | NB-3681(a)-1 Stress Indices for Use With Equations in NB-3650 <\/td>\n<\/tr>\n | ||||||
165<\/td>\n | NB-3683.1(c)-1 <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | NB-3683.1(d)-1 <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | NB-3683.6-1 <\/td>\n<\/tr>\n | ||||||
171<\/td>\n | NB-3684-1 Direction of Stress Components <\/td>\n<\/tr>\n | ||||||
172<\/td>\n | NB-3685.1-1 Curved Pipe or Welding End Elbows, Internal Pressure <\/td>\n<\/tr>\n | ||||||
173<\/td>\n | NB-3685.1-2 Curved Pipe or Welding End Elbows, Moment Loading (\u03bb\u22650.2) <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | NB-3685.2-1 Elbow Nomenclature NB-3686.1-1 <\/td>\n<\/tr>\n | ||||||
175<\/td>\n | NB-3686.2-1 NB-3686.5-1 Branch Connections in Straight Pipe <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | NB-3686.6-1 Reducers <\/td>\n<\/tr>\n | ||||||
179<\/td>\n | NB-4221.1-1 Maximum Difference in Cross\u2011Sectional Diameters <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | NB-4221.2(a)-1 Maximum Permissible Deviatione From a True Circular Form <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | NB-4221.2(a)-2 Maximum Arc Length for Determining Plus or Minus Deviation <\/td>\n<\/tr>\n | ||||||
182<\/td>\n | NB-4232-1 Maximum Allowable Offset in Final Welded Joints <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | NB-4233(a)-1 Butt Weld Alignment and Mismatch Tolerances for Unequal I.D. and O.D. When Components Are Welded From One Side and Fairing Is Not Performed <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | NB-4243-1 Acceptable Full Penetration Weld Details for Category C Joints (NB-3352.3) <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | NB-4244(a)-1 Nozzles Joined by Full Penetration Butt Welds <\/td>\n<\/tr>\n | ||||||
187<\/td>\n | NB-4244(b)-1 Nozzles Joined by Full Penetration Corner Welds <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | NB-4244(c)-1 Deposited Weld Metal Used as Reinforcement of Openings for Nozzles <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | NB-4244(d)-1 Partial Penetration Nozzles <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | NB-4244(d)-2 Partial Penetration Nozzle for Coaxial Cylinders <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | NB-4244(e)-1 Oblique Connections <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | NB-4246(a)-1 Typical Piping Branch Connections Joined by Full Penetration Welds <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | NB-4246(b)-1 Typical Piping Branch Connections Joined by a Fillet Weld or a Partial Penetration Weld <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | NB-4250-1 Welding end Transitions \u2014 Maximum Envelope <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | NB-4250-2 Component to Pipe Weld NB-4250-3 Pipe to Pipe Weld <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | NB-4427-1 Fillet and Socket Weld Details and Dimensions <\/td>\n<\/tr>\n | ||||||
204<\/td>\n | NB-4433-1 Types of Attachment Welds <\/td>\n<\/tr>\n | ||||||
205<\/td>\n | NB-4440-1 Appurtenance Weld Joint Details Size NPS 2 (DN 50) and Smaller <\/td>\n<\/tr>\n | ||||||
207<\/td>\n | NB-4511-1 Brazed Connections for Appurtenances and Piping, NPS 1 (DN 25) and Less <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | NB-4524-1 Maximum Design Temperatures for Brazing Filler Metal <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | NB-4622.1-1 Mandatory Requirements for Postweld Heat Treatment of Welds <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | NB-4622.4(c)-1 Alternative Holding Temperatures and Times <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | NB-4622.7(b)-1 Exemptions to Mandatory PWHT <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | NB-4622.9(d)(1)-1 Dissimilar Metal Repair Cavity Measurement <\/td>\n<\/tr>\n | ||||||
218<\/td>\n | NB-5111-1 Thickness, IQI Designations, Essential Holes, and Wire Diameters <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME BPVC – III – 1 – NB -2013 BPVC Section III, Rules for Construction of Nuclear Facility Components, Division 1, Subsection NB, Class 1 Components<\/b><\/p>\n |