{"id":338031,"date":"2024-10-19T23:38:45","date_gmt":"2024-10-19T23:38:45","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-iso-96222013\/"},"modified":"2024-10-25T22:44:37","modified_gmt":"2024-10-25T22:44:37","slug":"bs-iso-96222013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-iso-96222013\/","title":{"rendered":"BS ISO 9622:2013"},"content":{"rendered":"
This International Standard gives guidelines for the quantitative compositional analysis of milk and liquid milk products, such as raw milk, processed milk, cream and whey, by measurement of the absorption of mid-infrared radiation.<\/p>\n
Additional built-in instrument features, such as a conductivity sensor, can improve the performance in the determination of compositional parameters and allow for the estimation of other parameters.<\/p>\n
The guidelines specified are applicable to the analysis of cow\u2019s milk. The guidelines are also applicable to the analysis of milk of other species (goat, ewe, buffalo, etc.) and derived liquid milk products, provided adequate calibrations are generated for each application and adequate control procedures are in place.<\/p>\n
The application is limited to lower viscosity products that can be pumped through the flow system of the analyser and to analytes that do not result in optical saturation at the specific wavelengths being utilized.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Section sec_1 Section sec_2 Section sec_3 Section sec_3.1 Section sec_3.2 1\tScope 2\tNormative references 3\tTerms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Section sec_4 Section sec_5 Section sec_6 Section sec_6.1 Section sec_6.1.1 Section sec_6.1.2 Section sec_6.1.3 4\tPrinciple 5\tPrincipal characteristics of infrared instruments 6\tFactors affecting the measurements 6.1\tInstrument factors <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | Section sec_6.1.4 <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Table tab_1 Section sec_6.1.5 <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Section sec_6.1.6 Section sec_6.2 Section sec_6.2.1 6.2\tPhysico-chemical and biological factors <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Section sec_6.2.2 <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Section sec_6.2.3 Section sec_6.2.4 Section sec_6.2.5 Section sec_6.2.6 Section sec_6.2.7 Section sec_6.2.8 <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Section sec_6.2.9 Section sec_7 Section sec_7.1 Section sec_7.2 7\tCalibration of the instrument 7.1\tObjective 7.2\tSpectrum calibration models <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Section sec_7.3 Section sec_7.4 Section sec_7.4.1 Section sec_7.4.2 7.3\tCore settings 7.4\tChecking the slope and intercept <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Section sec_7.4.3 Section sec_7.4.4 Section sec_8 Section sec_9 Section sec_10 Section sec_10.1 Section sec_10.2 8\tSampling 9\tDetermination 10\tChecking daily short-term stability of the instrument 10.1\tGeneral 10.2\tPreparation and storage of control samples <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Section sec_10.3 Section sec_10.4 Section sec_10.5 Section sec_10.5.1 Section sec_10.5.2 10.3\tAnalysis of control samples 10.4\tMonitoring the analytical procedure 10.5\tRe-adjustment of instrument settings <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Section sec_11 Section sec_11.1 Section sec_11.2 Section sec_11.3 11\tPrecision 11.1\tRepeatability 11.2\tIntra-laboratory reproducibility 11.3\tReproducibility <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Section sec_12 12\tTest report <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Reference ref_1 Reference ref_2 Reference ref_3 Reference ref_4 Reference ref_5 Reference ref_6 Reference ref_7 Reference ref_8 Reference ref_9 Reference ref_10 Reference ref_11 Reference ref_12 Reference ref_13 Reference ref_14 Reference ref_15 Reference ref_16 Reference ref_17 Reference ref_18 Reference ref_19 Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Milk and liquid milk products. Guidelines for the application of mid-infrared spectrometry<\/b><\/p>\n |