{"id":273230,"date":"2024-10-19T18:21:04","date_gmt":"2024-10-19T18:21:04","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-14037-12016\/"},"modified":"2024-10-25T14:41:57","modified_gmt":"2024-10-25T14:41:57","slug":"bs-en-14037-12016","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-14037-12016\/","title":{"rendered":"BS EN 14037-1:2016"},"content":{"rendered":"
This European Standard defines technical specifications and requirements of free hanging<\/p>\n
The panels should be installed with an upper insulation.<\/p>\n
The European Standard does not apply to independent heating devices.<\/p>\n
The European Standard also defines the additional common data that the manufacturer has to provide to the trade in order to ensure the correct application of the products.<\/p>\n
This European standard does not cover the performance of hanging accessories.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
8<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4 Symbols and units <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5 Requirements 5.1 General manufacturing requirements 5.2 Surface protection <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3 Materials 5.4 Surface emissivity 5.5 Mechanical resistance 5.5.1 Horizontal curvature of radiant ceiling panels <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.5.2 Vertical deflection of radiant ceiling panels 5.6 Resistance to fixings 5.7 Pressure tightness 5.8 Resistance to pressure 5.9 Dimensional tolerances <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.10 Upper Insulation 5.11 Water flow resistance 5.12 Release of dangerous substances 5.13 Reaction to fire 5.13.1 General 5.13.2 Pre-fabricated ceiling mounted radiant panels classified as Class A1 without the need for testing <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5.13.3 Pre-fabricated ceiling mounted radiant panels classified according to the test results 5.14 Rated thermal output and characteristic equation 5.15 Surface temperature 6 Assessment and verification of constancy of performance – AVCP 6.1 General 6.2 Type testing 6.2.1 General <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.2.2 Test samples, testing and compliance criteria <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.2.3 Test reports 6.2.4 Shared other party results <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.3 Factory production control (FPC) 6.3.1 General 6.3.2 Requirements 6.3.2.1 General <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.3.2.2 Equipment 6.3.2.3 Raw materials and components <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.3.2.4 Controls during manufacturing process 6.3.2.5 Product testing and evaluation <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.3.2.6 Non-complying products <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.3.2.7 Corrective action 6.3.2.8 Handling, storage and packaging 6.3.3 Product specific requirements 6.3.4 Initial inspection of factory and of FPC <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 6.3.5 Continuous surveillance of FPC 6.3.6 Procedure for modifications <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7 Technical documentation 7.1 General 7.2 Designation of the pre-fabricated ceiling mounted radiant panels 7.3 Maximum operating pressure 7.4 Maximum operating temperature 7.5 Thermal output respectively cooling capacity 7.6 Dimensions and technical data <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 7.7 Reference data 7.8 Installation manual <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex\u00a0ZA (informative)Relationship of this European Standard with Regulation (EU) No. 305\/2011 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Free hanging heating and cooling surfaces for water with a temperature below 120\u00b0C – Pre-fabricated ceiling mounted radiant panels for space heating. Technical specifications and requirements<\/b><\/p>\n |