{"id":248873,"date":"2024-10-19T16:24:01","date_gmt":"2024-10-19T16:24:01","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-b30-3-2019\/"},"modified":"2024-10-25T11:35:18","modified_gmt":"2024-10-25T11:35:18","slug":"asme-b30-3-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-b30-3-2019\/","title":{"rendered":"ASME B30.3 2019"},"content":{"rendered":"

B30.3 applies to “construction tower cranes” and “permanently mounted tower cranes” that are powered by electric motors or internal combustion engines and that adjust their operating radius by means of a luffing boom mechanism, a trolley traversing a horizontal jib, or a combination of the two. The cranes may be mounted on “fixed bases” or “traveling bases” and may have tower and supporting structure arrangements that permit the crane to climb in a structure being built or that permits’ increasing the crane’s tower height as the structure rises. Variations of the above physical characteristics that provide the same fundamental operating characteristics are included in the scope of this Volume however, the requirements of this Volume are only applicable to the cranes within this scope when they are used in lifting operations. Mobile cranes configured with tower attachments (refer to ASME B30.5) and self-erecting tower cranes (refer to ASME B30.29) are not within the scope of this Volume.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nCONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
8<\/td>\nASME B30 COMMITTEE ROSTER <\/td>\n<\/tr>\n
10<\/td>\nB30 STANDARD INTRODUCTION <\/td>\n<\/tr>\n
13<\/td>\nASME B30.3-2019 SUMMARY OF CHANGES <\/td>\n<\/tr>\n
14<\/td>\nChapter 3-0 Scope, Definitions, References, and Personnel Competence
SECTION 3-0.1: SCOPE OF B30.3
SECTION 3-0.2: DEFINITIONS
3-0.2.1 Types of Cranes
3-0.2.2 General <\/td>\n<\/tr>\n
15<\/td>\nFigures
Figure 3-0.2.1.2-1 Hammerhead Tower Crane \u2014 Fixed-Base, Freestanding Crane <\/td>\n<\/tr>\n
16<\/td>\nFigure 3-0.2.1.2-2 Guyed Tower Crane <\/td>\n<\/tr>\n
17<\/td>\nFigure 3-0.2.1.2-3 Luffing Boom Tower Crane \u2014 Fixed-Base, Freestanding Crane <\/td>\n<\/tr>\n
18<\/td>\nFigure 3-0.2.1.3-1 Braced Crane <\/td>\n<\/tr>\n
19<\/td>\nFigure 3-0.2.1.3-2 Internal Climbing Crane <\/td>\n<\/tr>\n
20<\/td>\nFigure 3-0.2.1.4-1 Travel Base for Freestanding Crane <\/td>\n<\/tr>\n
21<\/td>\nFigure 3-0.2.2-1 Types of Fixed Bases <\/td>\n<\/tr>\n
22<\/td>\nSECTION 3-0.3: REFERENCES <\/td>\n<\/tr>\n
23<\/td>\nSECTION 3-0.4: PERSONNEL COMPETENCE <\/td>\n<\/tr>\n
24<\/td>\nChapter 3-1 Erection, Climbing and Dismantling, Characteristics, and Construction
SECTION 3-1.1: DESIGN REQUIREMENTS FOR THE LOAD BEARING STRUCTURE
3-1.1.1 Verification of Strength and Stability
3-1.1.2 Where Stability Governs Lifting Performance
3-1.1.3 Where Structural Competence Governs Lifting Performance <\/td>\n<\/tr>\n
25<\/td>\n3-1.1.4 Out-of-Service Stability Requirements for Rail-Mounted Cranes
3-1.1.5 Design Wind Velocity
SECTION 3-1.2: SITE PLANNING
SECTION 3-1.3: CRANE BASE SUPPORTS <\/td>\n<\/tr>\n
26<\/td>\nSECTION 3-1.4: GENERAL ERECTION AND DISMANTLING REQUIREMENTS <\/td>\n<\/tr>\n
27<\/td>\nSECTION 3-1.5: FREESTANDING CRANES <\/td>\n<\/tr>\n
28<\/td>\nSECTION 3-1.6: CLIMBING CRANES
3-1.6.1 Top Climbing Cranes <\/td>\n<\/tr>\n
29<\/td>\n3-1.6.2 Internal Climbing Cranes
SECTION 3-1.7: PREOPERATION TESTS <\/td>\n<\/tr>\n
30<\/td>\nSECTION 3-1.8: ALTERED OR MODIFIED CRANES
SECTION 3-1.9: DOCUMENTATION <\/td>\n<\/tr>\n
31<\/td>\n3-1.9.1 Informational Literature
3-1.9.2 Load Rating Chart <\/td>\n<\/tr>\n
32<\/td>\nSECTION 3-1.10: LOAD HOIST AND LUFFING BOOM HOIST MECHANISMS
3-1.10.1 General Requirements
3-1.10.2 Hoist Drums
3-1.10.3 Brakes <\/td>\n<\/tr>\n
33<\/td>\n3-1.10.4 Sheaves
3-1.10.5 Running Ropes
SECTION 3-1.11: HOOKS
SECTION 3-1.12: SLEWING (SWING) MECHANISM
3-1.12.1 General Requirements
3-1.12.2 Slewing Brakes
SECTION 3-1.13: TRAVEL EQUIPMENT
3-1.13.1 General Requirements
3-1.13.2 Travel Bogies
3-1.13.3 Travel Brakes <\/td>\n<\/tr>\n
34<\/td>\nSECTION 3-1.14: CLIMBING EQUIPMENT
SECTION 3-1.15: TROLLEYS (LOAD)
SECTION 3-1.16: BRAKES
SECTION 3-1.17: OPERATOR AIDS <\/td>\n<\/tr>\n
35<\/td>\nSECTION 3-1.18: PENDANTS, STAY ROPES, AND GUYS
SECTION 3-1.19: REEVING ACCESSORIES
SECTION 3-1.20: COUNTERWEIGHT AND BALLAST BLOCKS
SECTION 3-1.21: CONTROLS
3-1.21.1 Crane Function Controls
3-1.21.2 Main Power Supply System Controls <\/td>\n<\/tr>\n
36<\/td>\n3-1.21.3 Control Forces and Movements
SECTION 3-1.22: ELECTRICAL EQUIPMENT
3-1.22.1 General Requirements
3-1.22.2 Resistors
SECTION 3-1.23: OPERATOR\u2019S CABS
3-1.23.1 Construction
3-1.23.2 Access
3-1.23.3 Tool Box
3-1.23.4 Fire Extinguisher <\/td>\n<\/tr>\n
37<\/td>\n3-1.23.5 Signal Device
SECTION 3-1.24: GENERAL REQUIREMENTS
3-1.24.1 Footwalks and Ladders
3-1.24.2 Guards for Moving Parts
3-1.24.3 Lubrication Points
3-1.24.4 Exhaust Gases
3-1.24.5 Welded Construction
3-1.24.6 Clutch Protection and Adjustment
3-1.24.7 Wind Velocity Device
3-1.24.8 Fuel Filler Pipes
3-1.24.9 Hydraulic and Pneumatic Pressures <\/td>\n<\/tr>\n
38<\/td>\nChapter 3-2 Inspection, Testing, and Maintenance
SECTION 3-2.1: INSPECTION
3-2.1.1 General
3-2.1.2 Inspection Classification
3-2.1.3 Frequent Inspection
3-2.1.4 Periodic Inspection <\/td>\n<\/tr>\n
39<\/td>\n3-2.1.5 Major Inspection
SECTION 3-2.2: TESTING
3-2.2.1 Operational Tests
3-2.2.2 Operational Test Procedures for Crane Limit Devices <\/td>\n<\/tr>\n
40<\/td>\nSECTION 3-2.3: MAINTENANCE
3-2.3.1 Preventive Maintenance
3-2.3.2 Maintenance, Adjustments, and Repair Procedures
SECTION 3-2.4: ROPE INSPECTION, REPLACEMENT, AND MAINTENANCE
3-2.4.1 General
3-2.4.2 Inspection <\/td>\n<\/tr>\n
41<\/td>\n3-2.4.3 Rope Replacement
Figure 3-2.4.2-1 Core Failure in Rotation-Resistant Rope <\/td>\n<\/tr>\n
42<\/td>\n3-2.4.4 Rope Maintenance <\/td>\n<\/tr>\n
43<\/td>\nChapter 3-3 Operation
SECTION 3-3.1: QUALIFICATIONS FOR AND CONDUCT OF OPERATORS AND OPERATING PRACTICES
3-3.1.1 Operators
3-3.1.2 Qualifications for Operators <\/td>\n<\/tr>\n
44<\/td>\n3-3.1.3 Conduct of Operators
3-3.1.4 Responsibilities <\/td>\n<\/tr>\n
48<\/td>\nSECTION 3-3.2: OPERATING PRACTICES
3-3.2.1 Handling the Load <\/td>\n<\/tr>\n
49<\/td>\n3-3.2.2 Personnel Lifting
SECTION 3-3.3: SIGNALS
3-3.3.1 General
3-3.3.2 Standard Signals
3-3.3.3 Signalperson Qualifications
3-3.3.4 Standard Hand Signals
3-3.3.5 Standard Voice Signals
3-3.3.6 Special Signals <\/td>\n<\/tr>\n
50<\/td>\nFigure 3-3.3.4-1 Standard Hand Signals for Controlling Tower Cranes <\/td>\n<\/tr>\n
51<\/td>\n3-3.3.7 Audible Emergency Signal
SECTION 3-3.4: MISCELLANEOUS
3-3.4.1 Rail Clamps
3-3.4.2 Ballast or Counterweight <\/td>\n<\/tr>\n
52<\/td>\n3-3.4.3 Crane Operation in the Vicinity of Electric Power Lines <\/td>\n<\/tr>\n
53<\/td>\nFigure 3-3.4.3.1-1 Flow Chart to Assist in Determination of Applicable Section of Crane Operation Near Electric Power Lines <\/td>\n<\/tr>\n
54<\/td>\nFigure 3-3.4.3.1-2 Proximity to Power Lines \u2014 Elevation View <\/td>\n<\/tr>\n
55<\/td>\nFigure 3-3.4.3.1-3 Proximity to Power Lines \u2014 Plan View
Table
Table 3-3.4.3.1-1 Specified Clearance in the Vicinity of Energized Electric Power <\/td>\n<\/tr>\n
56<\/td>\nFigure 3-3.4.3.1-4 Typical Voltage <\/td>\n<\/tr>\n
57<\/td>\n3-3.4.4 Cabs
3-3.4.5 Refueling
3-3.4.6 Fire Extinguishers <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASME B30.3-2019: Tower Cranes: Safety Standard for Cableways, Cranes, Derricks, Hoists, Hooks, Jacks, and Slings<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASME<\/b><\/a><\/td>\n2019<\/td>\n58<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":248878,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2643],"product_tag":[],"class_list":{"0":"post-248873","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asme","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/248873","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/248878"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=248873"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=248873"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=248873"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}