{"id":248715,"date":"2024-10-19T16:23:16","date_gmt":"2024-10-19T16:23:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60695-11-22017-tc\/"},"modified":"2024-10-25T11:34:17","modified_gmt":"2024-10-25T11:34:17","slug":"bs-en-60695-11-22017-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60695-11-22017-tc\/","title":{"rendered":"BS EN 60695-11-2:2017 – TC"},"content":{"rendered":"
IEC 60695-11-2:2017 is also available as \/2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60695-11-2:2017 gives the requirements for the production and confirmation of a nominal 1 kW propane\/air pre-mixed flame for use in fire hazard testing. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO\/IEC Guide 51. It is not intended for use by manufacturers or certification bodies. It has the status of a basic safety publication in accordance with IEC Guide 104 and ISO\/IEC Guide 51. This third edition of IEC 60695-11-2 cancels and replaces the second edition published in 2013. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: addition of an alternative production of the test flame; deletion of Annex B. In this standard, the following print types are used: terms defined within Clause 3: in bold type. Key words: Fire Hazard, Pre-Mixed Flame, Standardized 1 kW Test Flame<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
29<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 4 Burner\/supply arrangement 4.1 Requirements 4.2 Apparatus and fuel 4.2.1 Burner 4.2.2 Flow control <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 4.2.3 Copper block 4.2.4 Thermocouple 4.2.5 Temperature\/time indicating\/recording devices 4.2.6 Laboratory fumehood\/chamber 5 Production of the test flame 5.1 Selection of the method <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 5.2 Method A 5.3 Method B (alternative) 6 Confirmation of the test flame 6.1 Principle 6.2 Frequency of confirmatory tests <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 6.3 Procedure 7 Recommended arrangements for use of the test flame <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | Figures Figure 1 \u2013 Flame dimensions <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | Annex A (normative) Burner details, arrangements and confirmatory test A.1 Burner construction <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | Figure A.1 \u2013 General assembly Figure A.2 \u2013 Burner details (1) <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Figure A.3 \u2013 Burner details (2) <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | Figure A.4 \u2013 Burner details (3) <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | Figure A.5 \u2013 Burner details (4) <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | A.2 Gas supply arrangement Figure A.6 \u2013 Example of supply arrangement for burner <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | A.3 The copper block A.4 Confirmatory test Figure A.7 \u2013 Copper block <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Figure A.8 \u2013 Confirmatory test arrangement <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Fire hazard testing – Test flames. 1 kW pre-mixed flame. Apparatus, confirmatory test arrangement and guidance<\/b><\/p>\n |