NC EnergyConservationCode 09 2009
$18.42
North Carolina State Building Code: Energy Conservation Code
Published By | Publication Date | Number of Pages |
NC | 2009 | 74 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | NORTH CAROLINA STATE BUILDING CODE: ENERGY CONSERVATION CODE 2009 |
2 | COPYRIGHT |
3 | NORTH CAROLINA STATE BUILDING CODE COUNCIL SEPTEMBER 8, 2008 |
4 | NORTH CAROLINA DEPARTMENT OF INSURANCE |
5 | PREFACE |
7 | ORDINANCE |
9 | TABLE OF CONTENTS |
11 | CHAPTER 1 ADMINISTRATION SECTION 101 SCOPE AND GENERAL REQUIREMENTS SECTION 102 MATERIALS, SYSTEMS AND EQUIPMENT |
12 | TABLE 102.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR TABLE 102.1.3(2) DEFAULT DOOR U-FACTORS TABLE 102.1.3(3) DEFAULT GLAZED FENESTRATION SHGC SECTION 103 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGNOR INSULATING SYSTEMS SECTION 104 CONSTRUCTION DOCUMENTS |
13 | SECTION 105 INSPECTIONS SECTION 106 VALIDITY SECTION 107 REFERENCED STANDARDS |
15 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
19 | CHAPTER 3 CLIMATE ZONES SECTION 301 CLIMATE ZONES TABLE 301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS Deleted TABLE 301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS Deleted FIGURE 301 NORTH CAROLINAa SECTION 302 DESIGN CONDITIONS |
20 | FIGURE 301.1 CLIMATE ZONES |
21 | TABLE 301.1 CLIMATE ZONES BY COUNTY TABLE 301.2 WARM HUMID COUNTIES |
23 | CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY SECTION 401 GENERAL SECTION 402 BUILDING THERMAL ENVELOPE TABLE 402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa |
24 | TABLE 402.1.3 EQUIVALENT U-FACTORSa |
25 | TABLE 402.2.4 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) TABLE 402.2.8 WALL INSULATION ALLOWANCES FOR TERMITE TREATMENT AND INSPECTION GAPS |
26 | SECTION 403 SYSTEMS (Mandatory) |
27 | SECTION 404 SIMULATED PERFORMANCE ALTERNATIVE (Performance) |
28 | TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
29 | TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS—continued |
30 | TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS—continued |
31 | TABLE 404.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa |
33 | CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY SECTION 501 GENERAL SECTION 502 BUILDING ENVELOPE REQUIREMENTS |
34 | TABLE 502.2(1) BUILDING ENVELOPE REQUIREMENTS—OPAQUE ASSEMBLIES |
35 | TABLE 502.2(2) METAL BUILDING ASSEMBLY DESCRIPTIONS EQUATION 5-1 |
36 | TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION |
37 | SECTION 503 BUILDING MECHANICAL SYSTEMS |
38 | TABLE 503.2.3(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
39 | TABLE 503.2.3(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
40 | TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
41 | TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS TABLE 503.2.3(6) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS |
42 | TABLE 503.2.3(7) WATER CHILLING PACKAGES, MINIMUM EFFICIENCY REQUIREMENTS |
43 | TABLE 503.2.3(8) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS < 150 TONS |
44 | TABLE 503.2.3(9) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS ≥ 150 TONS, ≤ 300 TONS |
45 | TABLE 503.2.3(10) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS > 300 TONS |
46 | TABLE 503.2.3(11) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT |
47 | EQUATION 5-2 |
48 | TABLE 503.2.8 MINIMUM PIPE INSULATIONa (thickness in inches) TABLE 503.3.1(1) ECONOMIZER REQUIREMENTS |
49 | TABLE 503.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS |
51 | SECTION 504 SERVICE WATER HEATING(Mandatory) SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS (Mandatory) |
52 | TABLE 504.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
54 | TABLE 505.5.2 INTERIOR LIGHTING POWER ALLOWANCES |
55 | TABLE 505.6.2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS |
56 | SECTION 506 TOTAL BUILDING PERFORMANCE |
59 | CHAPTER 6 REFERENCED STANDARDS AAMA AMCA ANSI ARI |
60 | ASHRAE ASME ASTM CSA CTI |
61 | DOE HI ICC IESNA NFRC |
62 | SMACNA UL WDMA |
63 | APPENDIX DETAIL 502.2.1.5(1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE DETAIL 502.2.1.5(2) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS DOWN TO 3 INCHES ABOVE INTERIOR GROUND SURFACE |
65 | INDEX |