MI PlumbingCode 06 2006
$35.21
Michigan Plumbing Code
Published By | Publication Date | Number of Pages |
MI | 2006 | 137 |
This is a fully integrated Custom Code based on the 2006 International Plumbing Code.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2006 MICHIGAN PLUMBING CODE |
3 | COPYRIGHT© 2007 |
4 | PREFACE |
6 | SAMPLE ORDINANCE STATE CODE |
8 | TABLE OF CONTENTS |
12 | CHAPTER 1 ADMINISTRATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
13 | SECTION 103 DEPARTMENT OF PLUMBING INSPECTION SECTION 104 DUTIES AND POWERS OF THE CODE OFFICIAL SECTION 105 APPROVAL |
14 | SECTION 106 PERMITS |
15 | SECTION 107 INSPECTIONS AND TESTING |
16 | SECTION 108 VIOLATIONS |
17 | SECTION 109 MEANS OF APPEAL |
18 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS |
26 | CHAPTER 3 GENERAL REGULATIONS SECTION 301 GENERAL SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM SECTION 303 MATERIALS |
27 | TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION SECTION 304 RODENTPROOFING SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS |
28 | SECTION 306 TRENCHING, EXCAVATION AND BACKFILL SECTION 307 STRUCTURAL SAFETY |
29 | SECTION 308 PIPING SUPPORT TABLE 308.5 HANGER SPACING SECTION 309 FLOOD HAZARD RESISTANCE |
30 | SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS SECTION 311 TOILET FACILITIES FOR WORKERS SECTION 312 TESTS AND INSPECTIONS |
31 | SECTION 313 EQUIPMENT EFFICIENCIES SECTION 314 CONDENSATE DISPOSAL |
34 | CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 401 GENERAL SECTION 402 FIXTURE MATERIALS SECTION 403 MINIMUM PLUMBING FACILITIES |
35 | TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa |
36 | TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa |
37 | TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa |
38 | SECTION 404 ACCESSIBLE PLUMBING FACILITIES SECTION 405 INSTALLATION OF FIXTURES FIGURE 405.3.1 FIXTURE CLEARANCE |
39 | SECTION 406 AUTOMATIC CLOTHES WASHERS SECTION 407 BATHTUBS SECTION 408 BIDETS SECTION 409 DISHWASHING MACHINES SECTION 410 DRINKING FOUNTAINS SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS SECTION 412 FLOOR AND TRENCH DRAINS |
40 | SECTION 413 FOOD WASTE GRINDER UNITS SECTION 414 GARBAGE CAN WASHERS SECTION 415 LAUNDRY TRAYS SECTION 416 LAVATORIES SECTION 417 SHOWERS |
41 | SECTION 418 SINKS SECTION 419 URINALS SECTION 420 WATER CLOSETS |
42 | SECTION 421 WHIRLPOOL BATHTUBS SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT |
43 | SECTION 423 SPECIALTY PLUMBING FIXTURES SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS |
44 | SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT SECTION 427 FLOOR SINKS |
46 | CHAPTER 5 WATER HEATERS SECTION 501 GENERAL SECTION 502 INSTALLATION SECTION 503 CONNECTIONS SECTION 504 SAFETY DEVICES |
47 | SECTION 505 INSULATION |
48 | CHAPTER 6 WATER SUPPLY AND DISTRIBUTION SECTION 601 GENERAL SECTION 602 WATER REQUIRED SECTION 603 WATER SERVICE SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM |
49 | TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES |
50 | TABLE 604.10.1 MANIFOLD SIZING SECTION 605 MATERIALS, JOINTS AND CONNECTIONS |
51 | TABLE 605.3 WATER SERVICE PIPE TABLE 605.4 WATER DISTRIBUTION PIPE |
52 | TABLE 605.5 PIPE FITTINGS TABLE 605.8 MANUFACTURED PIPE NIPPLES |
55 | SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS |
56 | TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS SECTION 607 HOT WATER SUPPLY SYSTEM |
57 | SECTION 608 PROTECTION OF POTABLE WATER SUPPLY TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION |
58 | TABLE 608.1 APPLICATION OF BACKFLOW PREVENTERS |
60 | TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS |
61 | SECTION 609 HEALTH CARE PLUMBING SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM SECTION 611 DRINKING WATER TREATMENT UNITS SECTION 612 SOLAR SYSTEMS |
62 | SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES |
64 | CHAPTER 7 SANITARY DRAINAGE SECTION 701 GENERAL SECTION 702 MATERIALS TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE |
65 | TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE TABLE 702.3 BUILDING SEWER PIPE |
66 | TABLE 702.4 PIPE FITTINGS SECTION 703 BUILDING SEWER SECTION 704 DRAINAGE PIPING INSTALLA TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE SECTION 705 JOINTS |
69 | TABLE 705.20 CAULKING FERRULE SPECIFICATIONS TABLE 705.21 SOLDERING BUSHING SPECIFICATIONS SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS |
70 | TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION SECTION 707 PROHIBITED JOINTS AND CONNECTIONS SECTION 708 CLEANOUTS |
71 | SECTION 709 FIXTURE UNITS TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS SECTION 710 DRAINAGE SYSTEM SIZING SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE |
72 | TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS |
73 | TABLE 710.1(1) BUILDING DRAINS AND SEWERS TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKSa |
74 | SECTION 712 SUMPS AND EJECTORS TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR |
75 | SECTION 713 HEALTH CARE PLUMBING |
76 | TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS SECTION 714 COMPUTERIZED DRAINAGE DESIGN SECTION 715 BACKWATER VALVES |
78 | CHAPTER 8 INDIRECT/SPECIAL WASTE SECTION 801 GENERAL SECTION 802 INDIRECT WASTES |
79 | SECTION 803 SPECIAL WASTES SECTION 804 MATERIALS, JOINTS AND CONNECTIONS |
80 | CHAPTER 9 VENTS SECTION 901 GENERAL SECTION 902 MATERIALS SECTION 903 OUTDOOR VENT EXTENSION SECTION 904 VENT TERMINALS |
81 | SECTION 905 VENT CONNECTIONS AND GRADES SECTION 906 FIXTURE VENTS TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT SECTION 907 INDIVIDUAL VENT SECTION 908 COMMON VENT TABLE 908.3 COMMON VENT SIZES SECTION 909 WET VENTING |
82 | TABLE 909.3 WET VENT SIZE SECTION 910 WASTE STACK VENT TABLE 910.4 WASTE STACK VENT SIZE SECTION 911 CIRCUIT VENTING |
83 | SECTION 912 COMBINATION DRAIN AND VENT SYSTEM TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE SECTION 913 ISLAND FIXTURE VENTING SECTION 914 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS |
84 | SECTION 915 VENTS FOR STACK OFFSETS SECTION 916 VENT PIPE SIZING TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS |
85 | TABLE 916.1—continued SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS SECTION 917 AIR ADMITTANCE VALVES |
86 | SECTION 918 ENGINEERED VENT SYSTEMS (EQUATION 9-1) SECTION 919 COMPUTERIZED VENT DESIGN |
87 | TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES |
88 | CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS SECTION 1001 GENERAL SECTION 1002 TRAP REQUIREMENTS SECTION 1003 INTERCEPTORS AND SEPARATORS |
89 | TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORS a |
90 | SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS |
92 | CHAPTER 11 STORM DRAINAGE SECTION 1101 GENERAL SECTION 1102 MATERIALS TABLE 1102.4 BUILDING STORM SEWER PIPE TABLE 1102.5 SUBSOIL DRAIN PIPE |
93 | TABLE 1102.7 PIPE FITTINGS SECTION 1103 TRAPS SECTION 1104 CONDUCTORS AND CONNECTIONS SECTION 1105 ROOF DRAINS SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS |
94 | FIGURE 1106.1 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES |
95 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES |
96 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES |
97 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA |
98 | FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII |
99 | TABLE 1106.2 SIZE OF VERTICAL CONDUCTORS AND LEADERS TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINGE PIPING |
100 | SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS SECTION 1108 COMBINED SANITARY AND STORM SYSTEM SECTION 1109 VALUES FOR CONTINUOUS FLOW SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS SECTION 1111 SUBSOIL DRAINS SECTION 1112 BUILDING SUBDRAINS SECTION 1113 SUMPS AND PUMPING SYSTEMS |
102 | CHAPTER 12 SPECIAL PIPING AND STORAGE SYSTEMS SECTION 1201 GENERAL SECTION 1202 MEDICAL GASES SECTION 1203 OXYGEN SYSTEMS |
104 | CHAPTER 13 REFERENCED STANDARDS ANSI ARI ASME |
105 | ASSE |
106 | ASTM |
109 | AWS AWWA CISPI CSA |
110 | ICC |
111 | ISEA NFPA NSF PDI UL |
112 | APPENDIX B RATES OF RAINFALL FOR VARIOUS CITIES |
114 | APPENDIX C GRAY WATER RECYCLING SYSTEMS SECTION C101 GENERAL SECTION C102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS |
115 | SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS |
116 | TABLE C103.8 LOCATION OF GRAY WATER SYSTEM TABLE C 103.9.1 DESIGN LOADING RATE TABLE C103.10 DISTRIBUTION PIPE |
117 | FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION |
118 | FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS |
120 | APPENDIX D DEGREE DAY AND DESIGN TEMPERATURES TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
121 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
122 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
123 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
124 | TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES |
126 | APPENDIX F STRUCTURAL SAFETY SECTION F101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS |
128 | APPENDIX G VACUUM DRAINAGE SYSTEM SECTION G101 VACUUM DRAINAGE SYSTEM |
130 | INDEX |