Shopping Cart

No products in the cart.

Chicago Energy Conservation Code, Title 14N:2019 Edition

$58.50

Chicago Energy Conservation Code, Title 14N

Published By Publication Date Number of Pages
IL 2019 170
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 2019 CHICAGO CONSTRUCTION CODES CHICAGO ENERGY CONSERVATION CODE TITLE 14N
2 COPYRIGHT
3 CITY OF CHICAGO OFFICE OF THE MAYOR MAYOR’S MESSAGE
4 CITY OF CHICAGO DEPARTMENT OF BUILDINGS COMMISSIONER’S MESSAGE
5 ABOUT THE CHICAGO CONSTRUCTION CODES
9 ACKNOWLEDGMENTS
17 PREFACE TO THE MODEL CODE
21 EFFECTIVE USE OF THE CHICAGO ENERGY CONSERVATION CODE
25 TABLE OF CONTENTS
27 CECC—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
29 CHAPTER C1 SCOPE AND PURPOSE
SECTION C101 GENERAL
31 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
37 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
39 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
40 EQUATION 4-1
EQUATION 4-2
TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
41 TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD
TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHOD
43 TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
EQUATION 4-4
44 EQUATION 4-5
46 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
47 SECTION C403 BUILDING MECHANICAL SYSTEMS
48 EQUATION 4-6
EQUATION 4-7
TABLE C403.3.3 MAXIMUM HOT GAS BYPASS CAPACITY
TABLE C403.3.4 BOILER TURNDOWN
49 TABLE C403.3.2(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
50 TABLE C403.3.2(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
51 TABLE C403.3.2(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
52 TABLE C403.3.2(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
53 TABLE C403.3.2(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
54 TABLE C403.3.2(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
TABLE C403.3.2(4) WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
55 TABLE C403.3.2(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.3.2(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
56 TABLE C403.3.2(7) WATER CHILLING PACKAGES – EFFICIENCY REQUIREMENTS
57 TABLE C403.3.2(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
58 TABLE C403.3.2(9) MINIMUM EFFICIENCY AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS
TABLE C403.3.2(10) HEAT TRANSFER EQUIPMENT
61 TABLE C403.5(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
TABLE C403.5.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
62 TABLE C403.5.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
66 TABLE C403.7.4(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
TABLE C403.7.4(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year)
TABLE C403.7.5 MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
67 TABLE C403.8.1(1) FAN POWER LIMITATION
68 TABLE C403.8.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
69 TABLE C403.8.5.1 COOLING SYSTEMS
70 TABLE C403.10.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATION
71 TABLE C403.10.1(2) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
72 TABLE C403.10.1(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS
74 TABLE C403.10.2.1(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.10.2.1(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEM EFFICIENCY REQUIREMENTS
75 EQUATION 4-8
76 TABLE C403.11.3 MINIMUM PIPE INSULATION THICKNESS (in inches)
SECTION C404 SERVICE WATER HEATING (MANDATORY)
77 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
78 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
79 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
80 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
82 EQUATION 4-9
84 FIGURE C405.2.3.2 SIDELIT ZONE
FIGURE C405.2.3.3(1) TOPLIT ZONE
FIGURE C405.2.3.3(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
85 FIGURE C405.2.3.3(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
EQUATION 4-10
86 EQUATION 4-11
87 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
88 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
89 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
90 TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
91 TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
92 TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
93 TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B, AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b
94 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
95 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C406 ADDITIONAL EFFICIENCY PACKAGES
96 SECTION C407 TOTAL BUILDING PERFORMANCE
98 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
99 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
100 TABLE C407.5.1(2) HVAC SYSTEMS MAP
101 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
102 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
103 SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
106 FIGURE C408.2.4 COMMISSIONING COMPLIANCE CHECKLIST
107 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
SECTION C502 ADDITIONS
108 SECTION C503 ALTERATIONS
109 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
111 CHAPTER 6 [CE] REFERENCED STANDARDS
AAMA
AHAM
AHRI
112 AMCA
ANSI
APSP
ASHRAE
113 ASTM
CSA
114 CTI
DASMA
DOE
IEEE
IES
115 ISO
NEMA
NFRC
SMACNA
UL
US-FTC
116 WDMA
117 INDEX
127 CECC—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
129 CHAPTER 1 [RE] SCOPE AND PURPOSE
SECTION R101 GENERAL
131 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
135 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
136 TABLE R303.1.3(1) DEFAULT GLAZED WINDOW, GLASS DOOR AND SKYLIGHT U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
137 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
138 TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE R402.1.4 EQUIVALENT U-FACTORSa
139 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES
142 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
143 SECTION R403 SYSTEMS
145 TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
TABLE R403.6.4.3(1) CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS
TABLE R403.6.4 INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORSa
146 EQUATION 4-1
TABLE R403.6.4.4 MINIMUM REQUIRED LOCAL EXHAUST RATE FOR DWELLING UNITS IN GROUP R-5 OCCUPANCIES
147 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
148 SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
149 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
150 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
151 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
152 EQUATION 4-2
TABLE R406.4 MAXIMUM ENERGY RATING INDEX
153 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
SECTION R502 ADDITIONS
154 SECTION R503 ALTERATIONS
155 SECTION R504 REPAIRS
SECTION R505 CHANGE OF OCCUPANCY OR USE
157 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
AMCA
APSP
ASHRAE
158 ASTM
CSA
DASMA
HVI
ICC
159 IEEE
NFRC
RESNET
UL
US-FTC
160 WDMA
161 INDEX
167 ICC EVALUATION SERVICE
168 ICC MEMBERSHIP
169 ICC ASSESSMENT CENTER
170 ICC DIGITAL CODES LIBRARY
Chicago Energy Conservation Code, Title 14N
$58.50