IEEE C37.017-2020(Redline)
$48.21
IEEE Standard for Bushings for High-Voltage (Over 1000 Vac) Circuit Breakers and Gas-Insulated Switchgear (Redline)
Published By | Publication Date | Number of Pages |
IEEE | 2020 |
Revision Standard – Active. This standard is applicable to bushings intended for use in high-voltage circuit breakers and gas-insulated switchgear. These bushings are intended for indoor and outdoor use, operating on alternating current with a rated voltage greater than 1000 V and a frequency of 50 Hz or 60 Hz. These bushings are usually a part of an apparatus and tested according to the apparatus of which they form part.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.017ā¢-2020 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
8 | Participants |
10 | Introduction |
11 | Contents |
13 | 1.āOverview 1.1āScope 1.2āPurpose 1.3āWord usage |
14 | 2.āNormative references |
15 | 3.āDefinitions, acronyms, and abbreviations 4.āNormal (usual) and special (unusual) service conditions 4.1āGeneral |
16 | 4.2āNormal (usual) service conditions 4.3āSpecial (unusual) service conditions for both indoor and outdoor applications 5.āRatings 5.1āGeneral |
17 | 5.2āRated maximum voltage 5.3āRated insulation level 5.4āRated power frequency 5.5āRated continuous current and temperature rise 5.6āRated short-time withstand current 5.7āRated peak withstand current |
18 | 5.8āRated duration of short circuit current 6.āDesign and construction 6.1āGeneral 6.2āExternal insulation housing 6.3āAngle of mounting 6.4āCreepage distance 6.5āTerminal loading, minimum withstand values |
19 | 6.6āSeismic qualification 6.7āNameplate markings |
20 | 7.āHollow insulators tests 7.1āGeneral 7.2āCeramic hollow insulators |
22 | 7.3āComposite hollow insulators |
24 | 8.āTests on bushings 8.1āGeneral requirements for tests 8.2āClassification of tests |
25 | 8.3āCondition of bushings during tests |
26 | 8.4āSpecimen to be tested 9.āDesign tests on bushings 9.1āDielectric tests |
29 | 9.2āArtificial pollution tests 9.3āRadio influence voltage and partial discharge measurement tests |
30 | 9.4āTemperature-rise tests 9.5āVerification of short-time current withstand 9.6āCantilever load withstand test |
31 | 9.7āTightness tests 9.8āInternal pressure test on gas-insulated bushings 9.9āVerification of dimensions 9.10āInformation to be included in design-test (type-test) reports |
32 | 10.āRoutine (production) tests 10.1āGeneral 10.2āDry power-frequency voltage withstand 10.3āPartial discharge test |
33 | 10.4āInternal pressure test 10.5āTightness test 10.6āDesign and visual checks |
34 | AnnexĀ A (informative) Bibliography |
35 | Back cover |