Shopping Cart

No products in the cart.

IEEE 1143 1995

$66.08

IEEE Guide on Shielding Practice for Low Voltage Cables

Published By Publication Date Number of Pages
IEEE 1995 79
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

New IEEE Standard – Active. A concise overview of shielding options for various types of interference and recommendations on shielding practices, including suggestions on terminating and grounding methods, are provided.

PDF Catalog

PDF Pages PDF Title
1 Title Page
3 Introduction
Participants
5 CONTENTS
7 1. Overview
1.1 Scope
1.2 Purpose
2. References
8 3. Definitions
11 4. Nature of interference
4.1 Definition of sources
4.2 Nature of interference
4.3 Source-circuit interaction
12 4.4 Types of interference
13 4.5 Sources of electromagnetic interference (EMI)
14 4.6 Electrical noise produced by power processing and control
15 5. Types of cable shielding
5.1 Introduction
17 5.2 Solid tube shield
18 5.3 Single layer foil shield with drain wire
20 5.4 Multilayer shield with drain wire
5.5 Spiral shield
5.6 Braided wire shield
21 5.7 Combination shields
22 5.8 Overall shields
24 5.9 Conductive plastics
25 5.10 Shield and armor options
27 5.11 Balanced mode transmission on twisted pairs
30 5.12 Balanced mode transmission on shielded twisted pairs
32 5.13 Twisted pairs for transmission of high-speed data
6. Shielding application principles
6.1 Functions
33 6.2 Single or multiconductor
6.3 Dedicated or multiplexed
6.4 Cable construction types
6.5 Cable selection
35 6.6 Shield types—application guide
36 7. Grounding and installation
7.1 Introduction
37 7.2 Shield grounded at one end
7.3 Shield grounded at both ends
7.4 Transient protection with overall shields
40 7.5 Grounding of cable with foil shields and overall shields
43 8. Shield testing methods
8.1 General
8.2 Continuous wave test methods
45 8.3 Testing of overall shield for single or multiconductor cable
50 9. Characterization of shielding
9.1 General
9.2 Shielding properties
51 9.3 Architectural shielding effectiveness
52 9.4 Transfer impedance
54 9.5 Shielding effectiveness of overall shield
55 9.6 Reduction factor with overall shields
56 9.7 Transient (lightning) protection by overall shields
57 9.8 Aging effect on shielding
63 10. Electrical noise susceptibility
10.1 Introduction
64 10.2 Galvanic action
10.3 Combination effect
65 10.4 Transients or repetitive noise
68 10.5 Nonlinear distortion
69 11. Interaction (coupling)
11.1 Introduction
11.2 Impedance coupling or common impedance coupling
11.3 Magnetic coupling
11.4 Quasistatic electric coupling
11.5 Coupling by electromagnetic radiation
70 11.6 Crosstalk
11.7 Crosstalk between coaxial cables
11.8 Electromagnetic crosstalk
71 12. Electrical noise susceptibility
12.1 Introduction
72 12.2 System boundaries
73 12.3 Sensitivity to noise
12.4 General susceptibility
12.5 Susceptibility to transient electrical noise
13. Noise induced from power systems
13.1 Introduction
74 13.2 Interaction model
76 14. Bibliography
IEEE 1143 1995