BSI PD IEC/TR 62689-100:2016
$215.11
Current and voltage sensors or detectors, to be used for fault passage indication purposes – Requirements and proposals for the IEC 61850 series data model extensions to support fault passage indicators applications
Published By | Publication Date | Number of Pages |
BSI | 2016 | 138 |
This part of IEC 62689, which is a Technical Report, was prepared jointly with TC 57 with the scope to prepare requirements and proposals for the IEC 61850 series data model extensions to support fault passage indicators (all classes and extended functions) applications to be introduced in the future IEC 61850906 and that, in turn, will be needed for the preparation of the future IEC 62689-3.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | CONTENTS |
8 | FOREWORD |
10 | INTRODUCTION |
11 | 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions |
12 | 3.2 Abbreviated terms 3.2.1 Generic abbreviated terms Tables Table 1 – Generic acronyms and abbreviated terms |
13 | 3.2.2 Proposed specifically for the data model part of this document Table 2 – Abbreviated terms for data object names |
14 | 3.2.3 Existing abbreviated terms used in IEC 61850 (all parts) data object names model Table 3 – Abbreviated terms of IEC 61850 (all parts) for data object names |
24 | 3.3 Fault classification definitions |
25 | 4 Requirements and use cases 4.1 General Table 4 – Fault types |
26 | 4.2 Common actors |
27 | Figures Figure 1 – Actors global hierarchy |
28 | Figure 2 – System Actors SGAM positioning (function) |
29 | Figure 3 – System Actors SGAM positioning (not function related) |
30 | Table 5 – List of common actors |
35 | 4.3 Use cases: fault indication and report 4.3.1 Generic use case – Not fault type specific |
37 | Figure 4 – Fault indication – Main use case |
38 | Figure 5 – Fault detection and indication – T1 |
39 | Figure 6 – Fault detection and indication– T2 |
40 | Figure 7 – Fault detection and indication for FPI – T3,T4 (with communicationto HV/MV SS) in the context of FLISR as described in 4.4.5 |
41 | Figure 8 – Fault detection and indication for FPI – T3,T4 (without communication to HV/MV SS) in the context of FLISR as described in 4.4.5 |
53 | 4.3.2 Overcurrent non directional Fault Localization and Indication (F1C/NC) |
54 | 4.3.3 Phase to earth faults, non directional fault detection (F2) 4.3.4 Overcurrent and phase to earth non directional faults detection (F3) Figure 9 – Voltage presence/absence |
55 | 4.3.5 Overcurrent, directional and non directional, fault detection (F4) 4.3.6 Overcurrent, non directional, phase to earth faults, directional and non directional fault detection (F5) 4.3.7 Overcurrents and phase to earth faults, directional and non directional fault detection (F6) 4.4 Use cases related to “other functions” 4.4.1 Report on device health 4.4.2 Monitor substation environment 4.4.3 Monitor external communication 4.4.4 Monitor energy flow (energy flow related use cases) |
56 | Figure 10 – Energy flow related use cases |
57 | Figure 11 – Sequence diagram for monitoring energy flows use cases |
61 | 4.4.5 Contribute to distributed automatic FLISR |
63 | Figure 12 – Logical selectivity – FLI along the MV feeder |
64 | Figure 13 – Logical selectivity – FLI inside the EU plant |
65 | Figure 14 – Logical selectivity – FLI along the MV feeder and anti-islanding |
66 | Figure 15 – Use case – fault location indication |
67 | Figure 16 – For further analysis |
77 | 4.4.6 Contribute to distributed automatic VVC 4.4.7 Contribute to distributed DER management 4.5 Use cases related to “Product life cycle” 4.5.1 IED configuration via CID file |
79 | Figure 17 – IED configuration process via CID |
80 | Figure 18 – FieldComp configuration – Main UC |
81 | Figure 19 – FieldComp asset management Figure 20 – Grid and topology planning |
82 | Figure 21 – Communication network planning |
83 | Figure 22 – First FieldComp connection to communication network |
84 | Figure 23 – New FieldComp configuration via CID – Remote + local (successful case) |
85 | Figure 24 – New FieldComp configuration via CID – Remote + local (unsuccessful case – corrupted CID) |
86 | Figure 25 – Existing FieldComp on-line reconfiguration – (topology – successful case) |
102 | 5 Information Models 5.1 Mapping of requirements on LNs 5.1.1 General 5.1.2 Mapping of the requirements of Fault Identification and report |
103 | 5.1.3 Mapping of the requirements of “other functions” Figure 26 – Possible arrangement of LNs to support fault passage indication |
104 | Figure 27 – Possible arrangement of LNs to support “Energy flow related use cases” |
105 | 5.1.4 Mapping of the requirements of “product life cycle” (FieldComp remote configuration) 6 Logical node classes 6.1 General Figure 28 – Possible arrangement of LNs to support CID Handling |
106 | 6.2 Package LNGroupL 6.2.1 General Figure 29 – Class diagram LogicalNodesJAHWG51::LogicalNodesJAHWG51 |
107 | Figure 30 – Statechart diagram LNGroupL::LNGroupL |
108 | 6.2.2 LICH LN Figure 31 – Class diagram LNGroupL::LNGroupL |
109 | 6.2.3 LN: Common LD Settings Name: LCLD Table 6 – Data objects of LICH |
110 | 6.3 Package LNGroupM 6.3.1 General Table 7 – Data objects of LCLD |
111 | 6.3.2 LN: Energy Name: MMTNExt Figure 32 – Class diagram LNGroupM::LNGroupM |
112 | Table 8 – Data objects of MMTNExt |
113 | 6.3.3 LN: Energy Name: MMTRExt |
114 | Table 9 – Data objects of MMTRExt |
115 | 6.3.4 LN: Measurement Name: MMXNExt |
116 | 6.3.5 LN: Measurement Name: MMXUExt Table 10 – Data objects of MMXNExt |
117 | Table 11 – Data objects of MMXUExt |
118 | 6.4 Package LNGroupS 6.4.1 General |
119 | 6.4.2 LN: Current presence monitoring Name: SCPI Figure 33 – Class diagram LNGroupS::LNGroupS Table 12 – Data objects of SCPI |
120 | 6.4.3 LN: Fault Passage Indicator Name: SFPI |
121 | Table 13 – Data objects of SFPI |
122 | 6.4.4 LN: Fault indicator statistic calculation Name: SFST Table 14 – Data objects of SFST |
123 | 6.4.5 LN: Voltage presence indicator Name: SVPI |
124 | Table 15 – Data objects of SVPI |
125 | 7 Data object name semantics and enumerations 7.1 Data semantics Table 16 – Attributes defined on classes of LogicalNodesJAHWG51 package |
128 | 7.2 Enumerated data attribute types 7.2.1 General |
129 | 7.2.2 CIDHandlingResultKind enumeration Figure 34 – Class diagram DOEnumsJAHWG51::DOEnumsJAHWG51 Table 17 – Literals of CIDHandlingResultKind |
130 | 7.2.3 CIDHandlingStatusKind enumeration 7.2.4 CurrentTransformersArrangementKind enumeration 7.2.5 FaultConfirmationModeKind enumeration Table 18 – Literals of CIDHandlingStatusKind Table 19 – Literals of CurrentTransformersArrangementKind Table 20 – Literals of FaultConfirmationModeKind |
131 | 7.2.6 FaultPermanenceKind enumeration 7.2.7 PwrFlwSignKind enumeration 8 SCL enumerations (from DOEnumsJAHWG51) Table 21 – Literals of FaultPermanenceKind Table 22 – Literals of PwrFlwSignKind |
132 | 9 References |
133 | Annex A (informative)Interpretation of logical node tables A.1 General interpretation of logical node tables A.2 Conditions for element presence Table A.1 – Interpretation of logical node tables |
134 | Table A.2 – Conditions for presence of elements within a context |
136 | Bibliography |