BS IEC 60800. Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation

Published By Publication Date Number of Pages
BSI 2020 31
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 UPI-NC
3 20_1899e_CD
9 1 Scope and object
2 Normative references
11 3 Terms and definitions
13 4 Mechanical classification
5 Requirement for marking
14 6 Requirements for installation instructions
15 7 General requirements for construction of cables
7.1 General
7.2 Conductors
7.3 Insulation
7.4 Electrically conducting screen
16 7.5 Armouring
7.6 Sheath
7.7 Moisture resistance
8 Testing
8.1 Type tests – General requirements
17 8.2 Type tests – Detailed test requirements
8.2.1 Electrical resistance of heating conductors and screen
8.2.2 Water immersion and temperature cycling test
8.2.2.1 General remark
18 8.2.2.2 Dielectric test
8.2.2.3 Electrical insulation resistance test
19 8.2.3 Verification of rated output for parallel heating cables
8.2.4 Verification of start-up current for parallel heating cables
8.2.5 Penetration test for electrically conductive screen and/or sheath
8.2.6 Flammability test
20 8.2.7 Deformation test for installation classification
8.2.7.1 General remark
21 8.2.7.2 Class M1: cables intended for installation with low risk of mechanical damage
8.2.7.3 Class M2: cables intended for installation with higher risk of mechanical damage
8.2.8 Cold impact test
22 8.2.9 Cold bend test
23 8.2.10 Ageing test for insulation
24 8.2.11 Ageing test for non-metallic sheath
8.2.12 Compatibility test
8.2.13 UV resistance test
25 8.2.14 Tensile test
26 8.2.15 Reverse winding test
8.2.16 Heat shock test
27 8.2.17 There shall be no cracks in the outer layer visible by visual inspection, both from the outside and from the inside after removing the sheath..If the sample fails during the test, two new samples shall be tested and if both samples pass the tes…
8.2.18 Hot set test
8.2.19 Cyclic ageing test for the heating cable
28 8.2.20 Cyclic ageing test for splices and end seals
8.2.21 Checking of the durability of markings
8.2.22 Pressure test at high temperature for insulation and sheath
29 8.3 Routine and sample tests
8.3.1 General remark
8.3.2 Voltage test
8.3.3 Heating cable resistance and output verification
8.3.4 Insulation thickness
8.3.5 Sheath thickness
30 8.3.6 Hot set test