BS EN IEC 60730-2-5 AMD2. Fragments 1-2. Automatic electrical controls – Part 2-5. Particular requirements for automatic electrical burner control systems
Published By | Publication Date | Number of Pages |
BSI | 2019 | 12 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | 1 Scope and normative references 1.1 Scope 2 Terms and definitions 2.2 Definitions of types of control according to purpose 7 Information |
5 | 11 Constructional requirements 11.102.2 Performance requirements 15 Manufacturing deviation and drift 15.5 Operating times |
6 | 17 Endurance 17.1 General requirements 17.1.3 Test sequence and conditions 25 Normal operation 27 Abnormal operation |
7 | Annex H (normative) Requirements for electronic controls H.2.23.3 H.26.9 Electrical fast transient/burst test H.26.9.3 Test procedure H.26.10 Ring wave test H.26.10.4 Test levels H.26.10.5 Test procedure H.26.12 Radio-frequency electromagnetic field immunity H.27.1.1.5 Electronic circuit fault conditions |
8 | H.27.1.2.3.2 First fault H.27.1.2.4.1 H.27.1.2.4.2 Second fault introduced during lock-out or safety shut-down H.27.1.2.4.3 Second fault introduced during defined state |
9 | Annex J (normative) Requirements for controls using thermistors |