Shopping Cart

No products in the cart.

BS ISO 9622:2013

$142.49

Milk and liquid milk products. Guidelines for the application of mid-infrared spectrometry

Published By Publication Date Number of Pages
BSI 2013 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This International Standard gives guidelines for the quantitative compositional analysis of milk and liquid milk products, such as raw milk, processed milk, cream and whey, by measurement of the absorption of mid-infrared radiation.

Additional built-in instrument features, such as a conductivity sensor, can improve the performance in the determination of compositional parameters and allow for the estimation of other parameters.

The guidelines specified are applicable to the analysis of cow’s milk. The guidelines are also applicable to the analysis of milk of other species (goat, ewe, buffalo, etc.) and derived liquid milk products, provided adequate calibrations are generated for each application and adequate control procedures are in place.

The application is limited to lower viscosity products that can be pumped through the flow system of the analyser and to analytes that do not result in optical saturation at the specific wavelengths being utilized.

PDF Catalog

PDF Pages PDF Title
6 Foreword
9 Section sec_1
Section sec_2
Section sec_3
Section sec_3.1
Section sec_3.2
1 Scope
2 Normative references
3 Terms and definitions
10 Section sec_4
Section sec_5
Section sec_6
Section sec_6.1
Section sec_6.1.1
Section sec_6.1.2
Section sec_6.1.3
4 Principle
5 Principal characteristics of infrared instruments
6 Factors affecting the measurements
6.1 Instrument factors
11 Section sec_6.1.4
12 Table tab_1
Section sec_6.1.5
13 Section sec_6.1.6
Section sec_6.2
Section sec_6.2.1
6.2 Physico-chemical and biological factors
14 Section sec_6.2.2
15 Section sec_6.2.3
Section sec_6.2.4
Section sec_6.2.5
Section sec_6.2.6
Section sec_6.2.7
Section sec_6.2.8
16 Section sec_6.2.9
Section sec_7
Section sec_7.1
Section sec_7.2
7 Calibration of the instrument
7.1 Objective
7.2 Spectrum calibration models
17 Section sec_7.3
Section sec_7.4
Section sec_7.4.1
Section sec_7.4.2
7.3 Core settings
7.4 Checking the slope and intercept
18 Section sec_7.4.3
Section sec_7.4.4
Section sec_8
Section sec_9
Section sec_10
Section sec_10.1
Section sec_10.2
8 Sampling
9 Determination
10 Checking daily short-term stability of the instrument
10.1 General
10.2 Preparation and storage of control samples
19 Section sec_10.3
Section sec_10.4
Section sec_10.5
Section sec_10.5.1
Section sec_10.5.2
10.3 Analysis of control samples
10.4 Monitoring the analytical procedure
10.5 Re-adjustment of instrument settings
20 Section sec_11
Section sec_11.1
Section sec_11.2
Section sec_11.3
11 Precision
11.1 Repeatability
11.2 Intra-laboratory reproducibility
11.3 Reproducibility
21 Section sec_12
12 Test report
22 Reference ref_1
Reference ref_2
Reference ref_3
Reference ref_4
Reference ref_5
Reference ref_6
Reference ref_7
Reference ref_8
Reference ref_9
Reference ref_10
Reference ref_11
Reference ref_12
Reference ref_13
Reference ref_14
Reference ref_15
Reference ref_16
Reference ref_17
Reference ref_18
Reference ref_19
Bibliography
BS ISO 9622:2013
$142.49