Shopping Cart

No products in the cart.

BS ISO 17299-5:2014:2015 Edition

$167.15

Textiles. Determination of deodorant property – Metal-oxide semiconductor sensor method

Published By Publication Date Number of Pages
BSI 2015 38
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

This part of ISO 17299 specifies a deodorant test method using an odour analyser equipped with multiple metal-oxide semiconductor sensors against composite odours. The artificial composite odours used in this part of ISO 17299 are a quasi sweat odour, a quasi body odour (nonenal mixture odour) and a quasi excrement odour.

This part of ISO 17299 applies to all kinds of textile products, such as woven fabrics, knits, threads, yarns, fibres, braids, cords, etc.

PDF Catalog

PDF Pages PDF Title
6 Foreword
7 Introduction
9 Section sec_1
Section sec_2
Section sec_3
Section sec_3.1
Section sec_3.2
Section sec_3.3
1 Scope
2 Normative references
3 Terms and definitions
10 Table tab_1
Section sec_3.4
Section sec_3.5
Section sec_3.6
Section sec_3.7
Section sec_3.8
Section sec_3.9
Section sec_4
Section sec_5
Section sec_5.1
Section sec_5.2
Section sec_5.3
Section sec_5.4
4 Principle
5 Reagents
11 Section sec_5.5
Section sec_5.6
Section sec_5.7
Section sec_5.8
Section sec_6
Section sec_6.1
Section sec_6.2
Section sec_6.3
Section sec_6.4
Section sec_6.5
Section sec_6.6
Section sec_6.7
Section sec_6.8
Section sec_6.9
Section sec_7
Section sec_7.1
Section sec_7.1.1
Section sec_7.1.2
Section sec_7.1.2.1
Section sec_7.1.2.2
Section sec_7.1.2.3
Section sec_7.1.3
Section sec_7.1.3.1
Section sec_7.1.4
Section sec_7.1.4.1
Section sec_7.1.4.2
Section sec_7.1.4.3
6 Apparatus and materials
7 Preparation of the odour test gas
7.1 Master gas
12 Section sec_7.1.4.4
Table tab_2
Section sec_7.2
Table tab_3
Section sec_7.2.1
Section sec_7.2.1.1
Section sec_7.2.1.2
Section sec_7.2.1.3
7.2 Preparation of the test quasi unpleasant odours
13 Figure fig_1
Section sec_7.2.2
Section sec_7.2.2.1
Section sec_7.2.2.2
Section sec_7.2.2.3
Section sec_7.2.3
Section sec_7.2.3.1
Section sec_7.2.3.2
Section sec_7.2.3.3
Section sec_8
Section sec_9
Section sec_9.1
Section sec_9.2
Section sec_9.2.1
8 Sensor response check
9 Preparation of calibration curve
9.1 Initial concentration
9.2 Odour unit concentration for quasi unpleasant odours
14 Table tab_4
Section sec_9.2.2
Table tab_5
Section sec_9.3
Section sec_9.3.1
Section sec_9.3.1.1
Section sec_9.3.1.2
Table tab_6
Section sec_9.3.2
9.3 Creation of calibration curve for quasi unpleasant odours
15 Section sec_9.3.3
Section sec_9.3.3.1
Section sec_9.3.3.2
Section sec_10
Section sec_10.1
Table tab_7
Section sec_10.2
Section sec_10.3
Section sec_10.3.1
Section sec_10.3.2
Section sec_10.3.3
Section sec_10.3.4
10 Deodorant test
10.1 Preparation of test specimen
10.2 Conditioning of the specimen
10.3 Test procedure
16 Figure fig_2
Section sec_10.3.5
Section sec_10.3.6
Section sec_11
Section sec_11.1
Section sec_11.2
Section sec_11.3
Section sec_11.4
Section sec_12
11 Calculation of the odour unit concentration
12 Calculation of reduction rate
17 Section sec_13
13 Test report
18 Annex sec_A
Annex sec_A.1
Annex sec_A.2
Annex sec_A.3
Annex sec_A.4
Annex sec_A.5
Table tab_A.1
AnnexĀ A
(informative)

Example of the test

19 Annex sec_A.6
Annex sec_A.6.1
Table tab_A.2
Annex sec_A.6.2
Table tab_A.3
Annex sec_A.6.3
Annex sec_A.6.3.1
20 Table tab_A.4
Annex sec_A.6.3.2
Figure fig_A.1
Annex sec_A.7
21 Table tab_A.5
Annex sec_A.8
Annex sec_A.8.1
Annex sec_A.8.1.1
Table tab_A.6
Annex sec_A.8.1.2
22 Annex sec_B
Annex sec_B.1
Annex sec_B.1.1
Annex sec_B.1.2
Table tab_B.1
Annex sec_B.2
Annex sec_B.2.1
AnnexĀ B
(informative)

Specifications of the odour test instrument

23 Table tab_B.2
Annex sec_B.2.2
Figure fig_B.1
25 Annex sec_C
Annex sec_C.1
Annex sec_C.2
Annex sec_C.2.1
Annex sec_C.2.2
Annex sec_C.2.3
Annex sec_C.2.4
Annex sec_C.3
Annex sec_C.3.1
Annex sec_C.3.1.1
Table tab_C.1
Annex sec_C.3.1.2
AnnexĀ C
(informative)

Practical testing results

26 Table tab_C.2
Annex sec_C.3.1.3
Table tab_C.3
Table tab_C.4
Annex sec_C.3.1.4
Table tab_C.5
27 Annex sec_C.3.1.5
Table tab_C.6
Table tab_C.7
Annex sec_C.3.2
Annex sec_C.3.2.1
Table tab_C.8
Annex sec_C.3.2.2
28 Table tab_C.9
Annex sec_C.3.2.3
Table tab_C.10
Table tab_C.11
Annex sec_C.3.2.4
29 Table tab_C.12
Annex sec_C.3.2.5
Table tab_C.13
30 Table tab_C.14
Annex sec_C.3.3
Annex sec_C.3.3.1
Table tab_C.15
Annex sec_C.3.3.2
Table tab_C.16
31 Annex sec_C.3.3.3
Table tab_C.17
Table tab_C.18
Annex sec_C.3.3.4
Table tab_C.19
32 Annex sec_C.3.3.5
Table tab_C.20
Table tab_C.21
33 Annex sec_C.3.4
Table tab_C.22
34 Reference ref_1
Reference ref_2
Bibliography
BS ISO 17299-5:2014
$167.15