BS EN ISO 22232-1:2020
$189.07
Non-destructive testing. Characterization and verification of ultrasonic test equipment – Instruments
Published By | Publication Date | Number of Pages |
BSI | 2020 | 50 |
This document specifies methods and acceptance criteria within the frequency range of 0,5 MHz to 15 MHz, for assessing the electrical performance of digital ultrasonic instruments for pulse operation using A-scan display, for manual ultrasonic non-destructive testing with single- or dual-transducer probes. This document is also applicable for multi-channel instruments. This document can partly be applicable to ultrasonic instruments in automated systems, but other tests can be needed to ensure satisfactory performance.
This document excludes ultrasonic instruments for continuous waves.
This document also excludes ultrasonic phased array instruments, see e.g. ISO 18563-1. If a phased array instrument has dedicated connectors for single- or dual-transducer probes this document is applicable for these channels.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
4 | European foreword |
7 | Foreword |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
11 | 4 Symbols |
12 | 5 General requirements of conformity 6 Manufacturer’s technical specification for ultrasonic instruments |
15 | 7 Performance requirements for ultrasonic instruments |
17 | 8 Group 1 tests 8.1 Equipment required for group 1 tests |
18 | 8.2 Battery operational time 8.2.1 Procedure 8.2.2 Acceptance criterion 8.3 Stability after warm-up time 8.3.1 Procedure 8.3.2 Acceptance criteria |
19 | 8.4 Stability against temperature 8.4.1 Procedure |
21 | 8.4.2 Acceptance criterion 8.5 Stability against voltage variation 8.5.1 Procedure |
22 | 8.5.2 Acceptance criterion 8.6 Time base deviation 8.6.1 Procedure |
24 | 8.6.2 Acceptance criterion 8.7 Transmitter pulse parameters 8.7.1 General 8.7.2 Pulse repetition frequency 8.7.3 Effective output impedance |
25 | 8.8 Receiver 8.8.1 General 8.8.2 Cross talk from transmitter to receiver during transmission |
26 | 8.8.3 Dead time after transmitter pulse |
28 | 8.8.4 Dynamic range and maximum input voltage |
29 | 8.8.5 Receiver input impedance |
30 | 8.8.6 Time-corrected gain (TCG) |
31 | 8.9 Gates 8.9.1 General |
32 | 8.9.2 Gates with value output |
34 | 8.9.3 Gates with analogue output |
36 | 8.9.4 Gates with alarm output |
37 | 8.10 Highest digitized frequency 8.10.1 Procedure |
38 | 8.10.2 Acceptance criterion 8.11 Response time of digital ultrasonic instruments 8.11.1 General 8.11.2 Procedure |
39 | 8.11.3 Acceptance criterion 9 Group 2 tests 9.1 Equipment required for group 2 tests |
40 | 9.2 Physical state and external aspects 9.2.1 Procedure 9.2.2 Acceptance criterion 9.3 Transmitter voltage, pulse rise time and duration 9.3.1 Procedure |
43 | 9.3.2 Acceptance criteria 9.4 Receiver 9.4.1 General 9.4.2 Frequency response |
45 | 9.4.3 Noise level |
46 | 9.4.4 Gain linearity 9.4.5 Vertical display linearity |
48 | Annex A (normative) Special conditions for ultrasonic instruments with logarithmic amplifiers |
49 | Bibliography |