BS EN IEC 60947-9-1:2019

$142.49

Low-voltage switchgear and controlgear – Active arc-fault mitigation systems. Arc quenching devices

Published By Publication Date Number of Pages
BSI 2019 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 60947 covers low-voltage arc quenching devices, hereinafter referred to as AQDs, which are intended to eliminate arc-faults in low-voltage assemblies (typically low-voltage switchgear and controlgear assemblies in accordance with the IEC 61439 series), by creating a lower impedance current path, to cause the arcing current to transfer to the new current path. This new current path is maintained until a short-circuit protection device (SCPD) interrupts the short-circuit current.

AQDs are installed in low-voltage assemblies, connected to the main circuit, preferably as close as possible to all primary power sources.

Their rated voltage does not exceed 1 000 V AC or 1 500 V DC. This document does not cover:

  • sensors intended to detect arc-faults;

  • devices intended to trigger the functioning of the arc quenching device;

  • devices intended to interrupt arc-fault current;

  • special requirements for AQDs for use in explosive atmospheres (e.g. ATEX).

PDF Catalog

PDF Pages PDF Title
2 National foreword
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
9 English
CONTENTS
11 FOREWORD
13 INTRODUCTION
14 1 Scope
2 Normative references
15 3 Terms and definitions
4 Classification
4.1 According to the number of operations
4.1.1 Single shot AQD
16 4.1.2 Resettable AQD
4.2 According to the mounting characteristics
4.2.1 Fixed AQD
4.2.2 Withdrawable or plug-in AQD
5 Characteristics
5.1 Rated operational voltage (Ue)
5.2 Rated insulation voltage (Ui)
5.3 Rated impulse withstand voltage (Uimp)
5.4 Rated short-time withstand current (Icw)
5.5 Maximum voltage drop in low-impedance state
17 5.6 Maximum operating time
5.7 Number of operating cycles (of a resettable AQD)
5.8 Maximum permissible temperature of the AQD main circuit terminals
6 Product information
6.1 Nature of information
6.2 Marking
18 6.3 Instructions for installation, operation, maintenance, decommissioning and dismantling
7 Normal service, mounting and transport conditions
8 Constructional and performance requirements
8.1 Constructional requirements
Table 1 – Product information
19 8.2 Performance requirements
8.3 Electromagnetic compatibility (EMC)
20 9 Tests
9.1 Kind of tests
9.2 Compliance with constructional requirements
9.3 Type tests
9.3.1 Performance tests
22 9.3.2 Electromagnetic compatibility tests
23 9.4 Routine tests
9.4.1 Closing operation
9.4.2 Dielectric test
24 Annex A (informative)Rationale for defining the maximum voltage drop valuein low-impedance state
A.1 Condition for arc extinction
25 A.2 Determination of minimum distance and corresponding voltage drop
26 Bibliography
BS EN IEC 60947-9-1:2019
$142.49