BS EN 60444-8:2017

$102.76

Measurement of quartz crystal unit parameters – Test fixture for surface mounted quartz crystal units

Published By Publication Date Number of Pages
BSI 2017 22
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 60444 describes test fixtures suitable for leadless surface mounted quartz crystal units in enclosures as defined in IEC 61837 (all parts). These fixtures allow the measurement of (series) resonance frequency, (series) resonance resistance, and equivalent electrical circuit parameters L1, C1 and C0 using the measurement techniques specified in IEC 60444-5 and for the determination of load resonance frequency and load resonance resistance according to IEC TR 60444-4 and IEC 60444-11.

Two test fixtures are described in this document:

  1. A fixture using the π-network circuit with electrical values as described in IEC 60444-1 for measurements in transmission mode up to 500 MHz. This fixture includes optional means to add physical load capacitors for the measurement of load resonance parameters up to 30 MHz in accordance with IEC 60444-4. The range of load capacitance is 10 pF or more. Calibration of the measurement system and CL adapter board is explained hereinafter.

  2. A fixture based on the reflection method, suitable for a frequency range up to 1 200 MHz. No provisions for adding a physical load capacitance are anticipated. Load resonance parameters can be measured by using the method of IEC 60444-11.

PDF Catalog

PDF Pages PDF Title
2 National foreword
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
8 FOREWORD
10 INTRODUCTION
11 1 Scope
2 Normative references
3 Specifications
4 Leadless surface mounted quartz crystal units
4.1 Enclosure
12 4.2 Overtone and frequency range
5 Specifications of measurement method, test fixture
5.1 Specifications of measurement method
5.2 Specifications of transmission test fixture
Figures
Figure 1 – Transmission π-network test fixture: Simplified equivalent circuit diagram, frequency range from 1 MHz to 500 MHz
Figure 2 – Transmission π-network test Fixture with physical load capacitors: simplified equivalent circuit, frequency range from 1 MHz to 30 MHz
13 Figure 3 – Transmission π-network test fixture:Three-dimensional projection for the test fixture
14 Figure 4 – Transmission π-network test fixture: Mechanical design of the test fixture
15 5.3 Specifications of reflection test fixture
Figure 5 – Transmission π-network test fixture with physical load capacitors:Structure of the test fixture
16 Figure 6 – Design of the reflection test fixture
18 5.4 Measuring equipment
6 Calibration
6.1 Calibration of the transmission test system
6.2 Additional calibration of the transmission test system with CL adapter board
6.3 Calibration of the reflection measurement system
Figure 7 – Mechanical details of the reflection test fixture
19 Figure 8 – Calibration technique for the reflection test fixture
20 Bibliography