Shopping Cart

No products in the cart.

BS EN 60127-7:2016

$167.15

Miniature fuses – Miniature fuse-links for special applications

Published By Publication Date Number of Pages
BSI 2016 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 60127-7:2015 covers requirements for miniature fuse-links for special applications. This part of IEC 60127 is applicable to fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA. It does not apply to fuses completely covered by the subsequent parts of IEC 60269-1. It does not apply to miniature fuse-links for appliances intended to be used under special conditions, such as in corrosive or explosive atmospheres. This part of IEC 60127 applies in addition to the requirements of IEC 60127-1. Miniature fuse-links for special applications are not intended to be replaced by the end-user of an electrical/electronic appliance. The object of this part of IEC 60127 is to establish uniform test methods for miniature fuse-links for special applications, so as to allow verification of the values (for example melting time and breaking capacity values) specified by the manufacturer. This second edition cancels and replaces the first edition published in 2013. This edition includes the following significant technical changes with respect to the previous edition: – defining a test board for surface mount fuse-links, Figure 2; – defining test schedules for homogenous series. This publication is to be read in conjunction with /2. Keywords: fuse-links with a rated voltage not exceeding 1 000 V, a rated current not exceeding 20 A and a rated breaking capacity not exceeding 50 kA.

PDF Catalog

PDF Pages PDF Title
6 CONTENTS
7 FOREWORD
9 INTRODUCTION
10 1 Scope
2 Normative references
11 3 Terms and definitions
12 4 General requirements
5 Standard ratings
6 Marking
13 7 General notes on tests
15 Figures
Figure 1 – Standard test board for fuse-links with wire terminations
16 Figure 2 – Test board for surface mount fuse-links
17 Figure 3 – Test fuse base
18 8 Dimensions and construction
19 9 Electrical requirements
20 Figure 4 – Test circuits for breaking capacity tests
21 Tables
Table 1 – Power factor and time constant
24 Table 2 – Testing schedule for individual ampere ratings for a.c. or d.c. breaking capacity fuse-links
25 Table 3 – Testing schedule for individual ampere ratings for a.c. and d.c. breaking capacity fuse-links
26 Table 4 – Testing schedule for maximum ampere rating of a homogeneous series (a.c. or d.c. breaking capacity fuse-links)
27 Table 5 – Testing schedule for maximum ampere rating of a homogeneous series (a.c. and d.c. breaking capacity fuse-links)
28 Table 6 – Testing schedule for minimum ampere rating of a homogeneous series
Table 7 – Testing schedule for all intermediate ampere ratings of a homogeneous series
29 10 Standard sheets
32 Annex A (informative) Guidance on ratings to be specified by the manufactureror to be agreed upon with the testing house
Table A.1 – Guidance on ratings to be specified by the manufactureror to be agreed upon with the testing house
33 Bibliography
BS EN 60127-7:2016
$167.15