BS EN 15316-3:2017

$167.15

Energy performance of buildings. Method for calculation of system energy requirements and system efficiencies – Space distribution systems (DHW, heating and cooling), Module M3-6, M4-6, M8-6

Published By Publication Date Number of Pages
BSI 2017 40
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard covers energy performance calculation of water based distribution systems for space heating, space cooling and domestic hot water. This standard deals with the heat flux from the distributed water to the space and the auxiliary energy of the related pumps. The heat flux and the auxiliary energy for pumps can be calculated at any time-step (hour, month and year). The input and output data are mean values of the time step.

PDF Catalog

PDF Pages PDF Title
2 National foreword
8 1 Scope
10 2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
11 5 General description of the method – Output of the method
6 Calculation of heat losses and auxiliary energy of distribution systems
23 7 Quality control
8 Compliance check
24 Annex A (informative)Simplified input data correlations
A.1 General
A.2 Input correlations to the length of pipes in zones (buildings)
A.2.1 Space heating and space cooling distribution systems
25 A.2.2 Domestic hot water distribution systems:
26 A.2.3 Correlations of typical values of linear thermal transmittance:
A.2.4 Correlations for pressure loss per length:
27 A.2.5 Correlations for resistance ratio:
A.2.6 Correlations of additional resistances:
A.2.7 Correlations correction factor of the distribution system:
A.2.8 Correlations factor for recoverable auxiliary energy:
28 Annex B (informative)Simplified input data correlations
B.1 General
B.2 Input correlations to the length of pipes in zones (buildings)
B.2.1 Introduction
B.2.2 Network for space heating and space cooling systems
B.2.2.1 Sections
29 B.2.2.2 Input data to the correlation
B.2.2.3 Correlations
30 B.2.2.4 Boundary conditions
31 B.2.3 Network for domestic hot water systems
B.2.3.1 Sections
32 B.2.3.2 Input data to the correlation
B.2.3.3 Correlations
33 B.2.3.4 Boundary conditions
B.3 Input correlations to linear thermal transmittance of pipes in zones (buildings)
B.3.1 Introduction
B.3.2 Network for space heating, space cooling and domestic hot water systems
B.3.2.1 Sections
34 B.3.2.2 Input data to the correlation
B.3.2.3 Correlations
35 B.4 Input correlations to constants for distribution pumps
B.4.1 Introduction
B.4.2 Constants for the calculation of the expenditure energy factor of distribution pumps
B.5 Input correlations to additional resistances and resistance ratio
B.5.1 Introduction
36 B.5.2 Network for space heating, space cooling and domestic hot water systems
B.5.2.1 Correlations for pressure loss per length
B.5.2.2 Correlations for resistance ratio
B.5.2.3 Correlations additional resistances
B.5.2.4 Correlations correction factor of the distribution system
37 B.6 Input correlations factor for recoverable auxiliary energy
38 Annex C (informative)Input data – Energy efficiency index of real water-pumps
C.1 Product description data
C.2 Product technical data
BS EN 15316-3:2017