BS EN 14825:2013
$215.11
Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling. Testing and rating at part load conditions and calculation of seasonal performance
Published By | Publication Date | Number of Pages |
BSI | 2013 | 90 |
This European Standard covers air conditioners, heat pumps and liquid chilling packages. It applies to factory made units defined in EN 14511-1, except single duct, control cabinet and close control units.
This European Standard gives the calculation methods for the determination of reference seasonal energy efficiency SEER and SEERon and reference seasonal coefficient of performance SCOP, SCOPon and SCOPnet.
Such calculation methods may be based on calculated or measured values.
In case of measured values, this European Standard covers the test methods for determination of capacities, EER and COP values during active mode at part load conditions. It also covers test methods for electric power consumption during thermostat-off mode, standby mode, off-mode and crankcase heater mode.
This European Standard serves as an input for the calculation of the system energy efficiency in heating mode of specific heat pump systems in buildings, as stipulated in the standard EN 15316-4-2.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Contents Page |
7 | Foreword |
9 | Introduction |
10 | 1 Scope 2 Normative references 3 Terms, definitions, symbols, abbreviated terms and units 3.1 Terms and definitions |
19 | 3.2 Symbols, abbreviated terms and units |
21 | 4 Part load conditions in cooling mode 4.1 General 4.2 Air-to-air units |
22 | 4.3 Water-to-air units and brine-to-air units 4.4 Air-to-water units |
23 | 4.5 Water-to-water and brine-to-water units |
24 | 5 Part load conditions in heating mode 5.1 General |
25 | 5.2 Air-to-air units |
26 | 5.3 Water-to-air and brine-to-air units |
27 | 5.4 Air-to-water units 5.4.1 General |
28 | 5.4.2 Low temperature application |
31 | 5.4.3 Medium temperature application |
34 | 5.4.4 High temperature application |
37 | 5.4.5 Very high temperature application |
39 | 5.5 Water-to-water and brine-to-water units 5.5.1 General |
40 | 5.5.2 Low temperature application |
43 | 5.5.3 Medium temperature application |
46 | 5.5.4 High temperature application |
49 | 5.5.5 Very high temperature application |
51 | 6 Calculation methods for reference SEER and reference SEERon 6.1 General formula for calculation of reference SEER 6.2 Calculation of the reference annual cooling demand (QC) |
52 | 6.3 Calculation of the reference annual electricity consumption (QCE) 6.4 Calculation of reference SEERon |
53 | 6.5 Calculation procedure for determination of EERbin(Tj) values at part load conditions B, C, D 6.5.1 General 6.5.2 For air-to-air & water-to-air units 6.5.2.1 Calculation procedure for fixed capacity units 6.5.2.2 Calculation procedure for staged and variable capacity units |
54 | 6.5.3 Air-to-water, water-to-water & brine-to-water units 6.5.3.1 Calculation procedure for fixed capacity units 6.5.3.2 Calculation procedure for staged and variable capacity units 7 Calculation methods for reference SCOP, reference SCOPon and reference SCOPnet 7.1 General formula for calculation of reference SCOP |
55 | 7.2 Calculation of the reference annual heating demand (QH) 7.3 Calculation of the annual electricity consumption (QHE) 7.4 Calculation of reference SCOPon and reference SCOPnet |
56 | 7.5 Calculation procedure for determination of COPbin(Tj) values at part load conditions A, B, C, D 7.5.1 General |
57 | 7.5.2 For air-to-air, brine-to-air and water-to-air units 7.5.2.1 Calculation procedure for fixed capacity units 7.5.2.2 Calculation procedure for staged and variable capacity units 7.5.3 For air-to-water, water-to-water and brine-to-water units 7.5.3.1 Calculation procedure for fixed capacity units |
58 | 7.5.3.2 Calculation procedure for staged and variable capacity units 8 Test methods for testing capacities, EERbin(Tj) and COPbin(Tj) values during active mode at part load conditions 8.1 General 8.2 Basic principles |
59 | 8.3 Uncertainties of measurement |
60 | 8.4 Test procedures for units with fixed capacity 8.4.1 General 8.4.2 Air-to-air and water-to-air units – Determination of the degradation coefficient Cd 8.4.2.1 General |
61 | 8.4.2.2 Air-to-air units – Cooling mode 8.4.2.3 Air-to-air units – Heating mode 8.4.2.4 Water-to-air units – Cooling mode 8.4.2.5 Water-to-air units – Heating mode 8.4.3 Air-to-water units and water-to-water units – Determination of the degradation factor Cc |
62 | 8.5 Test procedure for staged and variable capacity units (air-to-air, air-to-water, water-to-air, water/brine-to-water) 8.5.1 Air-to-air & water-to-air units 8.5.2 Air-to-water and water/brine-to-water units 9 Test methods for electric power consumption during thermostat-off mode, standby mode and crankcase heater mode 9.1 Measurement of electric power consumption during thermostat-off mode |
63 | 9.2 Measurement of the electric power consumption during standby mode 9.3 Measurement of the electric power consumption during crankcase heater mode 9.4 Measurement of the electric power consumption during off mode 10 Test report |
64 | 11 Technical data sheet |
65 | Annex A (normative) Applicable climate bin hours and hours for active mode, thermostat-off, standby, off mode for air conditioners below and equal to 12 kW A.1 Climate bins A.1.1 Bin limit temperature A.1.2 Cooling A.1.3 Heating |
67 | A.2 Hours for active mode, thermostat-off, standby, off mode A.2.1 Cooling A.2.2 Heating A.3 Hours used for crankcase heater mode A.3.1 Cooling |
68 | A.3.2 Heating |
69 | Annex B (informative) Calculation example for reference SEERon and reference SEER –Application to a reverse cycle air-to-air unit with variable capacity B.1 Calculation of SEERon |
70 | B.2 Calculation of SEER B.2.1 Calculation of reference annual cooling demand (QC) according to Formula (2) |
71 | B.2.2 Calculation of reference SEER according to Formula (1) |
72 | Annex C (informative) Calculation example for reference SCOPon and reference SCOPnet of a fixed capacity air-to-water heat pump used for floor heating |
76 | Annex D (informative) Adaption of water temperature for fixed capacity units |
79 | Annex E (informative) Determination of reference annual cooling/heating demands and determination of hours for active mode, thermostat-off, standby, off mode and crankcase heater mode E.1 General E.2 Determination of reference annual cooling/heating demands and hours for active mode, thermostat-off, standby, off mode |
81 | E.3 Hours used for crankcase heater mode |
82 | Annex F (informative) Compensation method for air-to-water and water/brine-to-water units F.1 General F.2 Compensation system for reduced capacity test in cooling mode F.3 Compensation system for reduced capacity test in heating mode |
84 | Annex G (normative) Template for technical data sheet |
87 | Annex ZA (informative) Relationship between this European Standard and the requirements of Commission Regulation (EC) No 206/2012 |
88 | Bibliography |