Gypsum board products from reprocessing. Definitions, requirements and test methods

Published By Publication Date Number of Pages
BSI 2014 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard specifies the characteristics and performance of products which have been produced by reprocessing gypsum boards manufactured according to EN 520 , EN 15283‑1 and EN 15283‑2 . Reprocessing may include cutting, perforating, edge profiling, decorating and laminating membranes of other materials for functional or decorative purposes, attaching fixings including supports e.g. for partitions. Examples of reprocessing operations are given in Annex B.

The products are intended for use in wall, ceiling and floor applications, where they may be fixed directly to the background, or they are used in systems assembled in conjunction with the structure to form separate or suspended linings. The products can be customized to fit the intended application offering a wide range of aesthetic, functional and decorative solutions of modular or non-modular design.

This European Standard does not cover gypsum board thermal/acoustic insulation composite panels according to EN 13950 and prefabricated gypsum board panels with a cellular paperboard core according to EN 13915 .

PDF Catalog

PDF Pages PDF Title
6 Foreword
7 1 Scope
2 Normative references
8 3 Terms and definitions, symbols and abbreviations
3.1 Terms and definitions
9 3.2 Symbols and abbreviations
Table 1 — Symbols and abbreviations
4 Requirements
4.1 Mechanical characteristics
4.1.1 Flexural strength (expressed as flexural breaking load)
4.1.2 Stability of ceiling elements
4.1.3 Shear strength (strength of board/substructure connection)
4.1.4 Impact resistance
10 4.2 Fire behaviour
4.2.1 Reaction to fire
4.2.2 Resistance to fire
4.3 Water vapour permeability (expressed as water vapour resistance factor)
4.4 Acoustic properties
4.4.1 Direct airborne sound insulation
4.4.2 Acoustic absorption
4.4.3 Impact sound insulation
11 4.5 Thermal resistance (expressed as thermal conductivity)
4.6 Dangerous substances
4.7 Dimensions and tolerances
4.8 Thermal emissivity
4.9 X-ray protection
5 Test methods
5.1 Sampling
12 5.2 Stability determination
5.2.1 Principle
5.2.2 Apparatus
5.2.3 Procedure
5.2.4 Expression of results
5.3 Determination of thermal emissivity
5.3.1 Principle
5.3.2 Apparatus
13 5.3.3 Procedure
5.3.4 Expression of results
6 Assessment and verification of constancy of performance – AVCP
6.1 General
14 6.2 Type testing
6.2.1 General
6.2.2 Determination of the product type
6.2.3 Further type testing
6.3 Factory production control (FPC)
6.3.1 General
15 6.3.2 Personnel
6.3.3 Equipment
6.3.3.1 Testing
6.3.3.2 Manufacturing
6.3.4 Raw materials and components
6.3.5 Product testing and evaluation
6.3.6 Traceability and marking
6.3.7 Non-complying products
16 6.3.8 Corrective action
6.3.9 Other test methods
7 Designation of gypsum board products from reprocessing
8 Marking, labelling and packaging
17 Annex A (informative) Sampling procedure for testing
A.1 General
A.2 Sampling procedure
A.2.1 General
A.2.2 Random sampling1F )
A.2.3 Representative sampling
A.2.3.1 General
A.2.3.2 Sampling from a stack
18 A.2.3.3 Sampling from a consignment formed of banded or wrapped packs
19 Annex B (informative) Reprocessing operations
20 Annex C (normative) Mounting and fixing in the test according to EN 13823 (SBI test) and related information
C.1 General
C.2 Products which have only been changed by mechanical processes to alter their shape or dimensions
C.3 Products which are formed by adhesion of another material (or board) to the surface of the board
C.4 Mounting and fixing for products which are formed by operations other than those listed in C.2 and C.3 above
22 Figure C.1 — Mounting and fixing of board to a metal sub-structure
23 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation
ZA.1 Scope and relevant characteristics
24 Table ZA.1 — Relevant clauses for gypsum board products from reprocessing and intended use
ZA.2 Procedure for AVCP of gypsum board products from reprocessing
ZA.2.1 Systems of AVCP
25 Table ZA.2 — Systems of AVCP
26 Table ZA.3.1 — Assignment of AVCP tasks for gypsum board products from reprocessing under system 1 (for reaction to fire classes A1 (1), A2 (1), B (1), C (1)) and system 3 for stiffening and system 4 for other uses
27 Table ZA.3.2 — Assignment of AVCP tasks for gypsum board products from reprocessing under system 3 (for reaction to fire classes A1 (2), A2 (2), B (2), C (2), D, E) and for stiffening and under system 4 for other uses
Table ZA.3.3 — Assignment of AVCP tasks for gypsum board products from reprocessing under system 4 (for reaction to fire classes (A1 to E) (3), F) and under system 3 for stiffening and under system 4 for other uses
28 ZA.2.2 Declaration of performance (DoP)
ZA.2.2.1 General
ZA.2.2.2 Content
29 ZA.2.2.3 Example of DoP
31 ZA.3 CE marking and labelling
32 Figure ZA.1 — Example CE marking information of products under AVCP system 3 on the accompanying label, or on the packaging or on the accompanying commercial documents
Figure ZA.2 — Example CE marking information of products under AVCP system 3 on the product
33 Bibliography