BS EN 12831-1:2017

$215.11

Energy performance of buildings. Method for calculation of the design heat load – Space heating load, Module M3-3

Published By Publication Date Number of Pages
BSI 2017 98
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This European Standard covers methods for the calculation of the design heat load for single rooms, building entities and buildings, where the design heat load is defined as the heat supply (power) needed to maintain the required internal design temperature under design external conditions. Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000 -1. NOTE 1 In CEN ISO/TR 52000 2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation. NOTE 2 The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively. See also Clause 2 and Tables A.1 and B.1. (…)

PDF Catalog

PDF Pages PDF Title
2 National foreword
10 1 Scope
14 2 Normative references
3 Terms and definitions
17 4 Symbols and abbreviations
4.1 Symbols
18 4.2 Subscripts
21 5 Description of the methods
22 6 Standard method – Heat load of rooms, building entities and buildings
6.1 Output data
23 6.2 Input data
29 6.3 Calculation procedure
6.3.1 Design heat load
6.3.1.1 Building (build)
6.3.1.2 Building entity (BE)
30 6.3.1.3 Heated space (i)
31 6.3.2 Design transmission heat losses of a heated space (i)
6.3.2.1 Total and partial design transmission heat loss ΦT,i and ΦT,ix
6.3.2.2 Heat transfer coefficient directly to the exterior, HT,ie
32 6.3.2.3 Heat transfer coefficient to adjacent spaces HT,ia
33 6.3.2.4 Heat transfer coefficient through the ground HT,ig
6.3.2.5 Temperature adjustment factor fix,k
35 6.3.3 Design ventilation heat loss
6.3.3.1 General
6.3.3.2 Simplified Calculation in air-tight buildings with neither fan-assisted ventilation nor ATDs
36 6.3.3.3 General calculation model
40 6.3.3.4 Air tightness
41 6.3.3.5 Minimum air volume flow
6.3.3.6 Envelope surfaces Aenv,z/i
42 6.3.3.7 Estimation of supply and exhaust air temperatures
43 6.3.4 Additional heating-up power in intermittently heated spaces
44 6.3.5 Time constant
45 6.3.6 Heat transfer coefficients without temperature adjustment
46 6.3.7 External design temperature (climatic data)
48 6.3.8 Influence of the heat emission system in high rooms (ceiling height ≥ 4 m)
6.3.8.1 General
49 6.3.8.2 Mean internal surface temperatures
6.3.8.3 Mean internal air temperature
50 7 Simplified method for the calculation of the design heat load of a heated space (single rooms)
7.1 Output data
7.2 Input data
51 7.3 Calculation procedure
7.3.1 Design heat load of a heated space
52 7.3.2 Design transmission heat loss of a heated space
7.3.3 Design ventilation heat loss of a heated space
53 8 Simplified method for the calculation of the building design heat load
8.1 Output data
8.2 Input data
54 8.3 Calculation procedure
8.3.1 Building design heat load
55 8.3.2 Building design transmission heat loss
8.3.3 Design ventilation heat loss of a building
56 9 Compliance check
9.1 General
9.2 Dimensioning of heat emission systems
9.3 Dimensioning of heat generators
57 Annex A (normative)Input data, structure for default values
A.1 General
A.2 Input data for the standard method (6)
A.2.1 Consideration of thermal bridges
A.2.2 Correction of U-values for the influence of building element properties and meteorological conditions
A.2.3 Heat loss through the ground
58 A.2.4 Temperature adjustment for heat loss to unheated spaces
A.2.5 Internal temperatures of adjacent building entities
A.2.6 Influence of the heat emission system in high rooms
59 A.2.7 Specific thermal storage capacity ceff
A.2.8 Specific properties of air
60 A.2.9 Volume flow ratio between room (i) and zone (z)
A.2.10 Air tightness
A.2.11 Minimum air change rate
61 A.2.12 Coefficient for the volume flow ratio fqv,z
A.2.13 Estimation of design data of external ATDs
A.2.14 Pressure exponent for leakages
A.2.15 Adjustment factor for the orientation of the zone (orientation factor)
62 A.2.16 Adjustment factor for the number of exposed facades
A.2.17 Air volume flow through large openings
A.2.18 Additional heating-up power in intermittently heated spaces ϕhu
A.2.19 Heat gains Φgain
A.3 Input data for the simplified methods (7, 8)
A.3.1 Ratio between external and internal surface areas
63 A.3.2 Thermal bridges
A.3.3 Temperature correction factor fx
A.3.4 Air change rate
A.4 Input data for the standard method and the simplified methods
A.4.1 Climatic data
66 A.4.2 Internal design temperature
A.4.3 Simplified determination of U-Values
67 Annex B (informative)Input data, default values
B.1 General
B.2 Input data for the standard method (6)
B.2.1 Consideration of thermal bridges
B.2.2 Correction of U-values for the influence of building element properties and meteorological conditions
B.2.3 Heat loss through the ground
68 B.2.4 Temperature adjustment for heat loss to unheated spaces
B.2.5 Internal temperatures of adjacent building entities
B.2.6 Influence of the heat emission system in high rooms
69 B.2.7 Specific thermal storage capacity ceff
70 B.2.8 Specific properties of air
B.2.9 Volume flow ratio between room (i) and zone (z)
B.2.10 Air tightness
71 B.2.11 Coefficient for the volume flow ratio fqv,z
72 B.2.12 Estimation of design data of external ATDs
73 B.2.13 Pressure exponent for leakages
B.2.14 Adjustment factor for the orientation of the zone (orientation factor)
B.2.15 Adjustment factor for the number of exposed facades
B.2.16 Air volume flow through large openings
B.2.17 Additional heating-up power in intermittently heated spaces ϕhu
B.2.18 Heat gains Φgain
B.3 Input data for the simplified methods (7, 8)
B.3.1 Ratio between external and internal surface areas
74 B.3.2 Thermal bridges
B.3.3 Temperature correction factor fx
B.3.4 Air change rate
B.4 Input data for the standard method and the simplified methods
B.4.1 Climatic data
75 B.4.2 Internal design temperature
76 B.4.3 Simplified determination of U-Values
B.4.3.1 Simplified determination of U-values based on build year
77 B.4.3.2 Simplified determination of U-values for building elements with later mounted thermal insulation
B.4.3.3 Simplified determination of U-values based on temperature measurements
79 Annex C (informative)Detailed consideration of thermal bridges
80 Annex D (informative)Internal temperatures θu of adjacent building entities or adjacent unheated spaces within the same building
83 Annex E (informative)Equivalent thermal transmittance of building elements against ground
86 Annex F (informative)Estimation of heating-up power in intermittently heated spaces (6.3.4)
F.1 General
88 F.2 Determination of the specific heating-up power φhu,i based on the time of disuse
89 F.3 Determination of the specific heating-up power φhu,i based on the internal temperature drop during setback
91 Annex G (informative)External air volume flow through large openings
BS EN 12831-1:2017
$215.11