BS EN 1047-2:2019

$167.15

Secure storage units. Classification and methods of test for resistance to fire – Data rooms and data container

Published By Publication Date Number of Pages
BSI 2019 36
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified. Requirements are also specified for test specimens, the technical documentation of the test specimens, materials specimens, physical fittings, the correlation of test specimens with the technical documentation and the preparation for type testing, as test procedures as well as the series production. In addition, a scheme to classify data rooms and data containers from the test results is given (see Table 1). As well as providing protection against fire, correctly installed data rooms and data containers offer a defined protection against impacts caused by failure during fire of components and objects external to the data room or data container. Data rooms and data containers having the same design, protection and construction features (type and thickness of construction and protective materials, rebate geometry, lockings, doors, etc.) will only be given the same protection classification as that of the test specimen if the tolerances are within the ranges specified in Clause 7. NOTE This European Standard does not regulate the use of data rooms in the meaning of the building laws of the respective countries. In the construction of data rooms, it is advised to consider the respective national requirements.

PDF Catalog

PDF Pages PDF Title
2 National foreword
5 European foreword
7 Introduction
8 1 Scope
2 Normative references
9 3 Terms and definitions
10 4 Requirements and classification
11 5 Test specimens, technical documentation, material samples, physical fittings and correlation
5.1 General requirements for data rooms type A and B and data containers
5.1.1 General requirements for test specimens
12 5.1.2 Fire retarding seals
13 5.2 Data room type A test specimens
15 5.3 Data room type B test specimens
16 5.4 Data container test specimens
5.5 Test specimen — floor test
17 5.6 Assessment of construction variants
5.6.1 General
5.6.2 Test specimen — comparison test
18 5.7 Technical documentation of the test specimens
5.8 Material samples
5.9 Correlation of test specimen and technical documentation
6 Test methods
6.1 General
19 6.2 Test apparatus
20 6.3 Preparation of test specimens
27 6.4 Preparation of furnace
28 6.5 Conditioning including air conditioning
6.5.1 Data room
6.5.2 Data containers
6.5.3 Wall and floor panels (data rooms, data containers)
6.6 Test procedure
6.6.1 Data room and data container test
29 6.6.2 Impact test
30 6.6.3 Floor test
6.6.4 Comparison test
6.6.5 Examinations
31 6.7 Test report
7 Series production
7.1 General
32 7.2 Fire-retarding penetration seals and configurations in series production
33 8 Labelling
34 Annex A (normative) Design of the reinforced concrete slab for the floor test
35 Bibliography
BS EN 1047-2:2019