ASTM-F877 2011
$40.63
F877-11a Standard Specification for Crosslinked Polyethylene (PEX) Hot- and Cold-Water Distribution Systems
Published By | Publication Date | Number of Pages |
ASTM | 2011 | 7 |
ASTM F877-11a
Historical Standard: Standard Specification for Crosslinked Polyethylene (PEX) Hot- and Cold-Water Distribution Systems
ASTM F877
Scope
1.1 This specification covers requirements, test methods, and marking requirements for system components when tested with nominal SDR9 crosslinked polyethylene tubing as a system. Systems are intended for 100 psi (0.69 MPa) water service up to and including a maximum working temperature of 180Ā°F (82Ā°C). Requirements and test methods are included for materials, workmanship, dimensions and tolerances, burst pressure, sustained pressure, excessive temperature and pressure, and thermo-cycling tests. The components covered by this specification are intended for use in residential and commercial, hot and cold, potable water distribution systems or other applications such as municipal water service lines, radiant panel heating systems, hydronic baseboard heating systems, snow and ice melting systems, and building services pipe.
1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values stated in parentheses are provided for information only.
Note 1āSuggested hydrostatic design stresses and hydrostatic pressure ratings for tubing and fittings are listed in Appendix X1. Design, assembly, and installation considerations are discussed in Appendix X2. An optional performance qualification and an in-plant quality control program are recommended in Appendix X3.
1.4 The following safety hazards caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
Cold water supply/distribution systems–specifications; Crosslinked polyethylene (PEX) pipe/tube–specifications; Cycling; Failure end point–plastics; Hot water supply/distribution systems–specifications; Polyethylene (PE) tube–specifications; Thermal cycling test; Water supply/distribution systems–specifications
ICS Code
ICS Number Code 23.040.20 (Plastic pipes)
DOI: 10.1520/F0877-11A
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Terminology Materials Classification Requirements |
3 | Test Methods TABLE 1 TABLE 2 |
4 | Retest and Rejection Certification Marking Quality Assurance |
5 | X1. HYDROSTATIC DESIGN STRESS X1.1 X1.2 X1.3 TABLE X1.1 |
6 | X2. DESIGN, ASSEMBLY, AND INSTALLATION CONSIDERATIONS X2.1 Assembly X2.2 Installation X3. OPTIONAL PERFORMANCE QUALIFICATION AND IN-PLANT QUALITY-CONTROL PROGRAM FOR PEX HOT-WATER DISTRIBUTION SYSTEM COMPONENTS X3.1 Scope X3.2 Performance Qualifications X3.3 In-Plant Quality Control TABLE X3.1 TABLE X3.2 |