ASTM-F1264:2007 Edition

$44.96

F1264-03(2007)e1 Standard Specification and Test Methods for Intramedullary Fixation Devices

Published By Publication Date Number of Pages
ASTM 2007 18
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

ASTM F1264-03-e1-Reapproved2007

Historical Standard: Standard Specification and Test Methods for Intramedullary Fixation Devices

ASTM F1264

Scope

1.1 This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs), specify labeling and material requirements, provide test methods for characterization of IMFD mechanical properties, and identify needs for further development of test methods and performance criteria. The ultimate goal is to develop a standard which defines performance criteria and methods for measurement of performance-related mechanical characteristics of IMFDs and their fixation to bone. It is not the intention of this specification to define levels of performance or case-specific clinical performance of these devices, as insufficient knowledge to predict the consequences of the use of any of these devices in individual patients for specific activities of daily living is available. It is not the intention of this specification to describe or specify specific designs for IMFDs.

1.2 This specification describes IMFDs for surgical fixation of the skeletal system. It provides basic IMFD geometrical definitions, dimensions, classification, and terminology; labeling and material specifications; performance definitions; test methods and characteristics determined to be important to in-vivo performance of the device.

1.3 This specification includes four standard test methods:

1.3.1 Static Four-Point Bend Test Methodā€”Annex A1 and

1.3.2 Static Torsion Test Methodā€”Annex A2.

1.3.3 Bending Fatigue Test Methodā€”Annex A3.

1.3.4 Test Method for Bending Fatigue of IMFD Locking Screwsā€”Annex A4.

1.4 A rationale is given in Appendix X1.

1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

A1.1.1 This test method describes methods for static four-point bend testing of intrinsic, structural properties of intramedullary fixation devices (IMFDs) for surgical fixation of the skeletal system. This test method includes bend testing in a variety of planes relative to the major anatomic planes. The purpose is to measure bending strength and bending stiffness intrinsic to the design and materials of IMFDs.

A1.1.2 This test method is designed specifically to test IMFD designs that have a well-defined working length (WL) of uniform open or closed cross section throughout the majority of its length (WL ā‰„ 10Ɨ diameter) and is to be applied to the full length of the diaphysis of a femur, tibia, humerus, radius, or ulna. This is not applicable to IMFDs that are used to fix only a short portion of the diaphysis of any of the long bones or the diaphysis of small bones such as the metacarpals, metatarsals, phalanges, and so forth.

A1.1.3 This test method is not intended to test the extrinsic properties of any IMFD, that is, the interaction of the device with bone or other biologic materials.

A1.1.4 This test method is not intended to define case-specific clinical performance of these devices, as insufficient knowledge to predict the consequences of the use of any of these devices in individual patients is available.

A1.1.5 This test method is not intended to serve as a quality assurance document, and thus, statistical sampling techniques for batches from production of IMFDs are not addressed.

A1.1.6 This test method may not be appropriate for all types of implant applications. The user is cautioned to consider the appropriateness of the method in view of the devices being tested, the material of their manufacture, and their potential applications.

A1.1.7 The values stated in SI units are to be regarded as the standard.

A1.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

A2.1.1 This test method covers the test procedure for determining the torsional stiffness of intramedullary fixation devices (IMFDs). The central part of the IMFD, with a straight and uniform cross-section and away from screw holes or other interlocking features, is tested in a static test.

A2.1.2 IMFDs are indicated for surgical fixation of the skeletal system and are typically used in the femur, tibia, humerus, radius, or ulna. Devices that meet the IMFD specifications of Section 4, and other similar devices, are covered by this test method.

A2.1.3 This test method does not intend to test or provide information that will necessarily relate to the properties of fixation that an IMFD may obtain in a bone or any other connection with other devices.

A2.1.4 This test method is not intended to define case-specific clinical performance of these devices, as insufficient knowledge to predict the consequences of the use of any of these devices in individual patients is available.

A2.1.5 This test method is not intended to serve as a quality assurance document. Thus, statistical sampling techniques for batches from the production of IMFDs are not addressed.

A2.1.6 Unless otherwise indicated, the values stated in SI units are to be regarded as the standard. The values in parentheses are given for information only.

A2.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

A3.1.1 This test method covers the test procedure for performing cyclic bending fatigue testing of intramedullary fixation devices (IMFDs). The central part of the IMFD, with a straight and uniform cross section and away from screw holes or other interlocking features, is tested in cyclic four-point bending. This method may be used to determine a fatigue life at a specified maximum bending moment or to estimate a fatigue strength for a specified number of cycles.

A3.1.2 IMFDs are indicated for surgical fixation of the skeletal system and are typically used in the femur, tibia, humerus, radius, or ulna. Devices that meet the IMFD specifications of Section 4, and other similar devices, are covered by this test method.

A3.1.3 This test method is not intended to test or provide information that will necessarily relate to the properties of fixation which an IMFD may obtain in a bone, or any other connection with other devices.

A3.1.4 This test method is not intended to define case-specific clinical performance of these devices, as insufficient knowledge to predict the consequences of the use of any of these devices in individual patients is available.

A3.1.5 This test method is not intended to serve as a quality assurance document, and thus, statistical sampling techniques for batches from the production of IMFDs are not addressed.

A3.1.6 Unless otherwise indicated, the values stated in SI units are to be regarded as the standard. The values in parentheses are given for information only.

A3.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

A4.1.1 This test method covers the test procedure for performing cyclic bending fatigue testing of locking screws used for the fixation of intramedullary fixation devices (IMFDs). The central part of the screw is tested in cyclic three-point or four-point bending. This method may be used to determine a fatigue life at a specified maximum bending moment or to estimate a fatigue strength for a specified number of cycles.

A4.1.2 This test method is specifically applicable to screws described by Specification F 543, which are used to provide fixation of IMFDs in bone by transversely crossing through the IMFD from one cortex to the other. This test method may or may not be applicable to other types of orthopaedic bone screws.

A4.1.3 This test method does not address the connection between the IMFD and the screw.

A4.1.4 This test method is not intended to define case-specific clinical performance of these devices, as insufficient knowledge to predict the consequences of the use of any of these devices in individual patients is available.

A4.1.5 This test method is not intended to serve as a quality assurance document, and thus, statistical sampling techniques for batches from the production of screws are not addressed.

A4.1.6 Unless otherwise indicated, the values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only.

A4.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

bend testing; definitions; extraction; fatigue test; fracture fixation; implants; intramedullary fixation devices; orthopaedic medical device; performance; surgical devices; terminology; test methods; torsion test; trauma; Intramedullary fixation devices (IMFDs); Mechanical performance considerations; Orthopaedic medical devices–specifications; Performance–surgical materials/applications (specifications); Skeletal system; Static tests–orthopaedic materials/applications; Structural medical applications; Terminology–medical/surgical systems/applications; Torsion testing–medical/surgical devices/applications

ICS Code

ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics)

DOI: 10.1520/F1264-03R07E01

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Classification
Material
Performance Considerations and Test Methods
3 Marking, Packaging, Labeling, and Handling
Means for Insertion and Extraction
Keywords
FIG. 1
FIG. 2
4 A1. TEST METHOD FOR STATIC FOUR-POINT BEND TEST METHOD
A1.1 Scope
A1.2. Terminology
A1.3 Classification
A1.4 Procedure
5 FIG. A1.1
FIG. A1.2
6 FIG. A1.3
FIG. A1.4
7 A1.5 Number of Specimens
A1.6 Apparatus
A1.7 Precision and Bias
TABLE A1.1
8 A1.8 Report
A1.9 Rationale (Nonmandatory Information)
TABLE A1.2
TABLE A1.3
TABLE A1.4
9 A2. TEST METHOD FOR STATIC TORSIONAL TESTING OF INTRAMEDULLARY FIXATION DEVICES
A2.1 Scope
A2.2 Summary of Test Method
A2.3 Terminology
A2.4 Significance and Use
TABLE A1.5
10 A2.5 Apparatus
A2.6 Test Specimen
A2.7 Procedure
FIG. A2.1
11 A2.8 Calculation or Interpretation of Results
A2.9 Report
A2.10 Precision and Bias
A2.11 Rationale (Nonmandatory Information)
FIG. A2.2
FIG. A2.2
12 A3. TEST METHOD FOR BENDING FATIGUE TESTING OF INTRAMEDULLARY FIXATION DEVICES
A3.1 Scope
A3.2 Referenced Documents
A3.3. Terminology
A3.4 Summary of Test Method
FIG. A3.1
13 A3.5 Significance and Use
A3.6 Apparatus
A3.7 Test Specimen
A3.8 Procedure
14 A3.9 Calculation and Interpretation of Results
A3.10 Report
A3.11 Precision and Bias
A3.12 Rationale
15 A4. TEST METHOD FOR BENDING FATIGUE TESTING OF IMFD LOCKING SCREWS
A4.1 Scope
A4.2 Referenced Documents
A4.3. Terminology
A4.4 Summary of Test Method
FIG. A4.1
16 A4.5 Significance and Use
A4.6 Apparatus
A4.7 Test Specimen
A4.8 Procedure
FIG. A4.2
17 A4.9 Calculation and Interpretation of Results
A4.10 Report
A4.11 Precision and Bias
X1. RATIONALE
X1.1
X1.2
X1.3
ASTM-F1264
$44.96