ASTM-E1473:2009 Edition
$58.50
E1473-09 Standard Test Methods for Chemical Analysis of Nickel, Cobalt, and High-Temperature Alloys
Published By | Publication Date | Number of Pages |
ASTM | 2009 | 38 |
ASTM E1473-09
Historical Standard: Standard Test Methods for Chemical Analysis of Nickel, Cobalt, and High-Temperature Alloys
ASTM E1473
Scope
1.1 These test methods describe the chemical analysis of nickel, cobalt, and high-temperature alloys having chemical compositions within the following limits:
1.2 The test methods in this standard are contained in the sections indicated as follows:
1.3 Methods for the determination of several elements not included in these test methods can be found in Test Methods E 30, E 76, and E 1019.
1.4 Some of the concentration ranges given in 1.1 are too broad to be covered by a single method, and therefore, these test methods contain multiple methods for some elements. The user must select the proper test method by matching the information given in the scope and interference sections of each test method with the composition of the alloy to be analyzed.
1.5 The values stated in SI units are to be regarded as standard. In some cases, exceptions allowed in Practice E 380 are also used.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7 and in 13.4, 29.1, 66.3, 123.5, 124.14, 139.4, 139.5, 147.5, and 147.6.
8.1 This test method covers the determination of manganese in concentrations from 0.05 % to 2.00 %.
18.1 This test method covers the determination of sulfur in concentrations from 0.006 % to 0.1 %.
27.1 This test method covers the determination of silicon in concentrations from 0.05 % to 5.00 % in alloys containing not more than 0.1 % boron.
34.1 This test method covers the determination of cobalt in concentrations from 2 % to 75 %.
42.1 This test method covers the determination of cobalt in concentrations from 0.10 % to 5.0 %.
52.1 This test method covers the determination of copper in concentrations from 0.010 % to 1.50 %.
62.1 This test method covers the determination of total aluminum in concentrations from 0.20 % to 7.00 %.
70.1 This test method covers the determination of nickel in concentrations from 0.1 % to 84.0 %.
78.1 This test method covers the determination of tin in the range from 0.002 % to 0.10 %.
88.1 This test method covers the determination of molybdenum in concentrations from 0.01 % to 1.50 %.
100.1 This test method covers the determination of chromium in concentrations from 0.018 % to 1.00 %.
110.1 This test method covers the determination of chromium in concentrations from 0.10 % to 33.00 %.
119.1 This test method covers the determination of molybdenum in concentrations from 1.5 % to 30 %.
127.1 This test method covers the determination of iron in concentrations from 1.0 % to 50.0 %.
135.1 This test method covers the determination of niobium (columbium) in concentrations from 0.5 % to 6.0 %.
143.1 This test method covers the determination of tantalum in concentrations from 0.03 % to 1.0 %.
Keywords
aluminum; chromium; cobalt; cobalt-base alloys; copper; high temperature alloys; iron; manganese; molybdenum; nickel; nickel-base alloys; niobium; silicon; sulfur; tantalum; tin; Aluminum content–Ni/Ni alloys; Chemical analysis–metals/alloys; Chromium content–metals/alloys; Chromium content–Ni/Ni alloys; Cobalt content–Ni/Ni alloys; Nickel content–Ni/Ni alloys; High-temperature service applications–nickel; Iron content–Ni/Ni alloys; Manganese content–metals/alloys; Manganese content–Ni/Ni alloys; Molybdenum content–metals/alloys; Molybdenum content–Ni/Ni alloys; Nickel content–miscellaneous metals/alloys; Silicon content–metals/alloys; Silicon content–Ni/Ni alloys; Tantalum (Ta) content–metals/alloys; Spectrophotometry–atomic absorption; Sulfur–metals/alloys; Sulfur–Ni/Ni alloys; Tin content–metals/alloys; Tin content–Ni/Ni alloys; Aluminum content; Cobalt alloys; Gravimetric determination; High-temperature alloys; Ion exchange materials/applications; Nickel alloys (chemical analysis); Photometry; Titration
ICS Code
ICS Number Code 77.120.40 (Nickel, chromium and their alloys)
DOI: 10.1520/E1473-09
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope |
2 | Referenced Documents Terminology Significance and Use Apparatus, Reagents, and Instrumental Practice Interlaboratory Studies and Rounding Calculated Values Hazards Scope Summary of Test Method Concentration Range |
3 | Stability of Color Interferences Reagents Preparation of Calibration Curve Procedure |
4 | Calculation Precision and Bias Scope Summary of Test Method Interferences Apparatus TABLE 1 |
5 | TABLE 2 FIG. 1 |
6 | Reagents Calibration Procedure |
7 | Calculation Precision and Bias Scope Summary of Test Method Interferences Reagents TABLE 4 |
8 | Procedure Calculation Precision and Bias |
9 | Scope Summary of Test Method Interferences Apparatus Reagents |
10 | Procedure Calculation |
11 | Precision and Bias Scope Summary of Test Method Concentration Range Stability of Color Interferences Reagents Preparation of Calibration Curve TABLE 5 |
12 | Procedure Calculation Precision and Bias Scope Summary of Test Method Concentration Range TABLE 6 |
13 | Stability of Color Interferences Reagents Preparation of Calibration Curve Procedure |
14 | Calculation Precision and Bias Scope Summary of Test Method Interferences Apparatus TABLE 7 FIG. 2 |
15 | Reagents Procedure |
16 | Calculation Precision and Bias Scope Summary of Test Method Interferences Apparatus TABLE 8 |
17 | Reagents Procedure |
18 | Calculation Precision and Bias Scope Summary of Test Method Concentration Range Interferences TABLE 9 |
19 | Apparatus Reagents Preparation of Calibration Curve Procedure |
20 | Calculation Precision and Bias Scope Summary of Test Method Concentration Range Stability of Color Interferences TABLE 10 |
21 | Reagents Preparation of Calibration Curve for Concentrations from 0.01 % to 0.05 % Preparation of Calibration Curve for Concentrations from 0.05 % to 0.55 % |
22 | Preparation of Calibration Curve for Concentrations from 0.40 % to 1.50 % Procedure |
23 | Calculation Precision and Bias Scope Summary of Test Method Concentration Range Interferences Apparatus Reagents Preparation of Calibration Curves TABLE 11 |
24 | Procedure |
25 | Calculation Precision and Bias Scope Summary of Test Method Interferences Apparatus Reagents TABLE 12 |
26 | Standardization of Ferrous Ammonium Sulfate Solution |
27 | Procedure |
28 | Calculation Precision and Bias Scope Summary of Test Method Interferences Apparatus Reagents TABLE 13 |
29 | Procedure |
30 | Calculation Precision and Bias |
31 | Scope Summary of Test Method Interferences Apparatus Reagents Procedure TABLE 14 |
32 | Calculation Precision and Bias Scope Summary of Test Method Interferences Apparatus Reagents TABLE 15 |
33 | Procedure |
34 | Calculation Precision and Bias TABLE 16 |
35 | Scope Summary of Test Method Interferences Apparatus Reagents TABLE 3 |
36 | Preparation of Calibration Curve Procedure |
38 | Calculation Precision and Bias Keywords |