ASTM-D5542 2009

$40.63

D5542-04(2009) Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography

Published By Publication Date Number of Pages
ASTM 2009 9
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 These test methods cover the determination of trace ( ? g/L) levels of fluoride, acetate, formate, chloride, phosphate, and sulfate in high purity water using ion chromatography in combination with sample preconcentration. Other anions, such as bromide, nitrite, nitrate, sulfite, and iodide can be determined by this method. However, since they are rarely present in significant concentrations in high purity water, they are not included in this test method. Two test methods are presented and their ranges of application, as determined by a collaborative study, are as follows:

A Limit of detection is lowest measurable concentration not reportable as zero at 99 % level of confidence as per EPRI study as cited in Sections 15 and 23.

B Insufficient data to calculate limit of detection.

1.2 It is the user’s responsibility to ensure the validity of these test methods for waters of untested matrices.

1.3 The common practical range of Test Method A is as follows: chloride, 1 to 100 ? g/L, phosphate, 3 to 100 ? g/L, and sulfate, 2 to 100 ? g/L.

1.4 The common practical range of Test Method B is as follows: fluoride, 1 to 100 ? g/L, acetate, 10 to 200 ? g/L, and formate, 5 to 200 ? g/L.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

7.1 This test method is optimized for the quantitative determination of trace levels of chloride, phosphate, and sulfate. Anions such as fluoride, acetate, and formate can be detected by this method, but are not reliably resolved from each other. See Fig. 1 for a typical chromatogram.

7.2 Using a concentrated sample volume of 20 mL, the test method is applicable in the range outlined in Section 1. The range of this test method may be extended by concentrating a smaller or a larger sample volume. Be sure not to exceed concentrator column breakthrough volume (see annex).

16.1 This test method is optimized for the quantitative determination of trace levels of fluoride, acetate, and formate in high purity water and in water containing up to 2000 mg/L boron from boric acid. The range of the method is summarized in Section 1. See Fig. 3 for a typical chromatogram.

16.2 This test method does not respond to sulfate, since its elution time is very long.

16.3 Using a concentrated sample volume of 20 mL, the test method is applicable in the range outlined in Section 1. The range of this method may be extended upward by concentrating a smaller sample volume, or downward by concentrating a larger sample volume. When analyzing samples containing high amounts of boric acid (for example, 1 %), the volume concentrated should not exceed 30 mL, so as not to exceed the breakthrough volume for fluoride.

FIG. 3 Anions by Test Method B

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
2 Significance and Use
Reagents
Sampling
FIG. 1
3 Scope
Summary of Test Method
Interferences
Apparatus
FIG. 2
4 Reagents
Calibration
5 Procedure
Calculation
Precision and Bias (Test Method A)
Scope
TABLE 1
6 Quality Control
FIG. 3
7 Summary of Test Method
Interferences
Apparatus
Reagents
Calibration, Procedure, and Calculations
Precision and Bias (Test Method B)
8 Keywords
A1. DETERMINATION OF CONCENTRATOR COLUMN BREAKTHROUGH VOLUME
A1.1
A1.2
A1.3
TABLE 2
9 FIG. A1.1
ASTM-D5542 2009
$40.63