ASTM-D4486 2006
$40.63
D4486-91(2006) Standard Test Method for Kinematic Viscosity of Volatile and Reactive Liquids
Published By | Publication Date | Number of Pages |
ASTM | 2006 | 5 |
ASTM D4486-91-Reapproved2006
Historical Standard: Standard Test Method for Kinematic Viscosity of Volatile and Reactive Liquids
ASTM D4486
Scope
1.1 This test method covers the measurement of kinematic viscosity of transparent, Newtonian liquids which because of their reactivity, instability, or volatility cannot be used in conventional capillary kinematic viscometers. This test method is applicable up to 2 10 5 N/m2 (2 atm) pressure and temperature range from 53 to +135°C (65 to +275°F).
1.1.1 For the measurement of the kinematic viscosity of other liquids, see Test Method D 445.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see 7.2, 7.3, 7.4, and Annex A1.
Keywords
kinematic viscosity; reactive liquid; viscosity; volatile liquid
ICS Code
ICS Number Code 17.060 (Measurement of volume, mass, density, viscosity)
DOI: 10.1520/D4486-91R06
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Summary of Test Method Significance and Use Apparatus |
2 | Reagents and Materials Standardization Cleaning of Viscometer TABLE 1 |
3 | Procedure for Kinematic Viscosity TABLE 2 TABLE 3 FIG. 1 |
4 | Calculation and Report Precision and Bias Keywords A1. WARNING STATEMENTS A1.1 Compressed Gases (Helium, Nitrogen) A1.2 Chromic Acid (Cleaning Solution) A1.3 Acetone A1.4 Hydrochloric Acid (Concentrated) |
5 | A2. CALIBRATION OF VISCOMETERS A2.1 Using Liquid Standards A2.2 Using Standard Viscometers |