ASTM-D2501:2011 Edition
$35.75
D2501-11 Standard Test Method for Calculation of Viscosity-Gravity Constant (VGC) of Petroleum Oils
Published By | Publication Date | Number of Pages |
ASTM | 2011 | 3 |
ASTM D2501-11
Historical Standard: Standard Test Method for Calculation of Viscosity-Gravity Constant (VGC) of Petroleum Oils
ASTM D2501
Scope
1.1 This test method covers the calculation of the viscosity-gravity constant (VGC) of petroleum oils having viscosities in excess of 5.5 mm2/s at 40°C (104°F) and in excess of 0.8 mm2/s at 100°C (212°F).
1.2 Annex A1 describes a method for calculating the VGC from Saybolt (SUS) viscosity and relative density.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3.1 The SI unit of kinematic viscosity is mm2/s.
1.3.2 Exception—Fahrenheit temperature units are used in this practice because they are accepted by industry for the type of legacy conversions described in this practice.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
aromatic; density; kinematic viscosity; paraffinic
ICS Code
ICS Number Code 75.080 (Petroleum products in general)
DOI: 10.1520/D2501-11
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Summary of Test Method Significance and Use Measurement of Physical Properties |
2 | Calculation of Viscosity-Gravity Constant Report Precision and Bias Keywords A1. CALCULATION OF VISCOSITY-GRAVITY CONSTANT FROM SAYBOLT VISCOSITY AND RELATIVE DENSITY (SPECIFIC GRAVITY) A1.1 A1.2 From Saybolt Viscosity at 100°F and Relative Density (Specific Gravity) 60/60°F A1.3 From Saybolt Viscosity at 210°F and Relative Density (Specific Gravity) 60/60°F A1.4 |
3 | X1. REVISION HISTORY X1.1 |