Shopping Cart

No products in the cart.

ASTM-C1316:2008 Edition

$44.96

C1316-08 Standard Test Method for Nondestructive Assay of Nuclear Material in Scrap and Waste by Passive-Active Neutron Counting Using 252Cf Shuffler

Published By Publication Date Number of Pages
ASTM 2008 17
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

1.1 This test method covers the nondestructive assay of scrap and waste items for U, Pu, or both, using a 252 Cf shuffler. Shuffler measurements have been applied to a variety of matrix materials in containers of up to several 100 L. Corrections are made for the effects of matrix material. Applications of this test method include measurements for safeguards, accountability, TRU, and U waste segregation, disposal, and process control purposes (1, 2, 3) .

1.1.1 This test method uses passive neutron coincidence counting (4) to measure the 240 Pu-effective mass. It has been used to assay items with total Pu contents between 0.03 g and 1000 g. It could be used to measure other spontaneously fissioning isotopes such as Cm and Cf. It specifically describes the approach used with shift register electronics; however, it can be adapted to other electronics.

1.1.2 This test method uses neutron irradiation with a moveable Cf source and counting of the delayed neutrons from the induced fissions to measure the 235 U equivalent fissile mass. It has been used to assay items with 235 U contents between 0.1 g and 1000 g. It could be used to assay other fissile and fissionable isotopes.

1.2 This test method requires knowledge of the relative isotopic composition (See Test Method C 1030 ) of the special nuclear material to determine the mass of the different elements from the measurable quantities.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 The techniques described in this test method have been applied to materials other than scrap and waste. These other applications are not addressed in this test method.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 8.

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
2 Terminology
Summary of Test Method
Significance and Use
3 FIG. 1
4 Interferences
Apparatus
5 FIG. 2
FIG. 3
6 Hazards
FIG. 4
7 Initial Preparation of Apparatus
8 FIG. 5
9 Procedure
FIG. 6
10 Calculations
12 Precision and Bias
FIG. 7
13 FIG. 8
FIG. 9
14 FIG. 10
15 Keywords
REFERENCES